Non-Contact Power Supply Using the Series-Parallel Resonant Converter (직ㆍ병렬 공진형 컨버터를 이용한 비접촉전원)

  • Kong Young-Su;Kim Eun-Soo;Yang Seung-Chul;Kim Jong-Mu;Shin Byung-Chul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.405-412
    • /
    • 2004
  • In this paper, Non-contact power supply(NCPS) with the long primary cable longer than 20m and the large air-gap between the primary and secondary of Non-Contacting Transformer(NCT) is presented. The NCT has a large leakage inductance bigger than its magnetizing inductance because it has low coupling, and it is not efficient for NCPS to transfer the primary energy to the secondary one. In order to improve this problem, the voltage-gain characteristics of the series resonant converter, the parallel resonant converter, and the series-parallel resonant converter are analyzed respectively. In addition, the experimental results of 10kW prototype the series-parallel resonant converter is presented.

Development of New Conveyer Directly Driven by Contact-less Energy Transmission System

  • Park, Hyung-Beom;Park, Han-Seok;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.18-23
    • /
    • 2009
  • This paper focuses on development of new conveyer directly driven by the contact-less energy transmission system. The effect of the resonant circuit and the flux linkage characteristics caused from that are analyzed by using 3D finite element analysis. From the result it is shown that the resonant circuit needs to transfer energy from the primary core to the secondary core. Also the influence of the linear induction motor on the contact-less energy transmission system is presented. New conveyer and the experimental apparatus was manufactured by using the contact-less energy transmission system and the linear induction motor. Possibility of realization of the conveyer is proved by comparison the simulation result which is obtained by using 2D finite element analysis with experimental one and the characteristic of the voltage and resonant current.

The Effects of Customer Contact Service to the Mental Health among Korean Taxi Drivers (택시운전원의 고객응대 노동이 정신건강에 미치는 영향)

  • Lee, Bokim
    • Korean Journal of Occupational Health Nursing
    • /
    • v.25 no.2
    • /
    • pp.108-117
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the relationship between customer contact service and mental health among Korean taxi drivers. Methods: This was a secondary analysis of data collected from the 2015 Korean Working Conditions Survey. The sample included 496 taxi drivers in South Korea. The effect of customer contact service on mental health was analyzed using logistic regression analysis. The independent variables were general characteristics, working conditions, and hazardous factors in interactive service. Results: The prevalence of poor mental health was 56.3%. Taxi drivers experienced emotional involvement (17.2%), hiding feeling (32.0%), and contact with angry clients (18.3%) in their job. During the first month of their work, 33.7% experienced verbal abuse and 12.3% threats/humiliating behaviors. In bivariate analysis, verbal abuse, threats/humiliating behaviors, and physical violence were associated with mental health of taxi drivers. Multiple logistic regression analysis revealed 'emotional involvement' and 'contact with angry clients' were significant predictors of mental health. Conclusion: The findings of this study may be useful in developing intervention programs to improve the mental health of taxi drivers in South Korea.

An Analysis on the Characteristics of the Contact-less Power Supply (무접점 전원장치의 특성분석)

  • Lee, Hyun-Kwan;Lee, Gi-Sik;Chung, Bong-Geun;Kang, Sung-In;Kong, Young-Su;Kim, Eun-Soo;Kim, Yoon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.919-922
    • /
    • 2006
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss in contact-less power supply (CPS). In this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is analyzed and simulated. The results are verified on the simulation based on the theoretical analysis and the 1.8kW experimental prototype.

  • PDF

A Study on the Distribution of Microorganisms in Department of Radiography (영상의학과 촬영실의 미생물 분포에 관한 연구)

  • Chang, Jeong-Hyun;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.165-171
    • /
    • 2021
  • To prevent the secondary hospital-acquired infection (cross-infection) from occurring in the general radiographic room in the department of radiology, the microbial measurement was conducted at the points making direct close contact with radiologists and patients. For the case of radiologists, the microbial measurement and incubation were focused on the x-ray tube handle of the radiation generating device, and, for the case of patients, the microbial measurement and incubation were focused on the chin supporting device, chest-contact point, and handle. Once disinfected with Aniosurf, the sterilized media were gathered and identified, and the microorganisms were confirmed. Based on the identification results, it was confirmed that the points making direct close contact with radiologists showed a value of 103 CFU for Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp. and Candida spp., and that the points making direct close contact with patients showed a value of 103~5 CFU for Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM(Non-Tuberculosis Mycobacteria) and Candida spp.. It was also confirmed that the types and number of microorganisms gathered from the points making direct close contact with patients were greater. Fortunately, most of the involved microorganisms were observed to be on the skin surface and are known to become extinct when disinfected in accordance with the hospital-acquired infection control rules. However, since even minor exposure to such microorganisms may be lethal for patients with reduced immunity, caution must be taken. In particular, since the points making contact with patients showed a high level of microbial measurement, it was thought that it would be necessary for radiologists and personnel having frequent access to strictly disinfect the parts, such as instruments and handles, making frequent contact with patients. The purpose of this study was to announce the importance of safe microbial control in the radiographic inspection room in hospital, and this study is expected to be used as the baseline data for preventing hospital-acquired secondary infection and Nth infectious diseases.

Bioceramic Effects to Enhance Secondary Metabolites Production in Tissue Culture of Some Medicinal Plants

  • Kim, Yu-Jeong;Hwang, Baik;Ahn, Jun-Cheul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.12 no.2
    • /
    • pp.118-122
    • /
    • 2004
  • We have investigated that a couple of soft ferrite ceramic powders having a spinal structure have shown the effect on growth and secondary metabolites production of some medicinal plants cultured in vitro. The addition of the ceramic powders as bare state to culture medium has stimulated the growth of Achyranthes japonica callus and plantlet, adventitious root of Hyoscyamus niger and Platycodon grandiflorum hairy root about 65, 75, 150 and 50%, respectively. Whereas Centella asiatica callus and plantlet, Scopolia parviflora hairy root, and Hyoscyamus albus adventitious root were not affected markedly. Moreover, the ceramic powder has enhanced the growth of H. niger adventitious roots even under conditions of irradiating alone without any direct contact between ceramic powder and media. Based on growth stimulation effect, the ceramic powders have enhanced the gross production of tropane alkaloid in H. niger adventitious root, and polyacetylene in P. grandiflorum hairy root about 35 and 30%, respectively.

A PHOTOMETRIC STUDY OF NEAR-CONTACT BINARY ZZ Aur (근접촉 식쌍성 ZZ Aur의 측광학적 연구)

  • 오규동;강영운;김호일;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.1
    • /
    • pp.31-38
    • /
    • 2002
  • The BVR CCD full light curves of ZZ Aur were obtained as one of the near-contact binary observing programs at the Sobaek Mt. Observatory during Feb. 2000 - Feb. 2001. From the present observations, three primary and seven secondary times of minimum light were obtained. The photometric solutions have been found using the Wilson and Divenny model.

A Photometric Study of the W UMa-type Contact Binary GX Aurigae

  • Park, Jang-Ho;Kim, Chun-Hwey;Lee, Jae-Woo
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.29.2-29.2
    • /
    • 2008
  • The CCD photometric observations of the W UMa type contact binary GX Aur were performed for 33 nights from 2004 to 2008 using a 2K CCD camera and Johnson BVRI filter system attached to the 61cm reflector at Sobaeksan Optical Astronomy Observatory (SOAO). From our observations, the first BVRI light curves of GX Aur were completed and eight new times of minima (primary: 4, secondary: 4) were obtained. All the times of minima including our timings were collected and analyzed to see the dynamical behavior of GX Aur system. Intensive analysis of our BVRI lightcurves with the recent Wilson-Devinney binary model shows that GX Aur is an over-contact binary whose component stars have equal mass and time-variable spots.