• 제목/요약/키워드: secondary contact

검색결과 284건 처리시간 0.026초

The characteristic analysis of contact-less Power supply by 3D finite element method

  • Park, Han-Seok;Cho, Yun-Hyun;Jung, Hong-Sub;Woo, Kyung-il;Kim, Kyung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.145-151
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of contact-less power supply by the 3D finite element method with a variation of the secondary core position. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. The magnetic coupling coefficients are obtained also. The power factors are obtained by simulation for the magnetic coupling coefficients and compared.

비접촉 전원장치의 비접촉 커플러 설계 (Non contact Coupler Design in Non contact Power Supply)

  • 류명효;차헌녕;백주원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1500-1502
    • /
    • 2005
  • In this paper, the electrical characteristics of the non-contact transformer is presented using conventional coupled inductor theory. Each non-contact transformer is analyzed through simulation and measurement. In high power applications, non-contact transformer is so bulky and heavy that it should be split by some light transformers. So non-contact transformer needs several small transformer modules which are connected series or parallel to transfer the primary power to the secondary one. This paper shows analytic result of the each non-contact transformer module and comparison result between series-connection and parallel-connection of the non-contact transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.

  • PDF

일부 도서지역의 보건의료에 대한 기초조사 II. 주민의 의료이용양상 및 의료기관에 대한 인식도 (The Survey on the Health Status of an Islands-District Residents II. The Medical Utilization Pattern and Recognition of Medical Facilities)

  • 고기호;문강;손석준;최진수
    • 농촌의학ㆍ지역보건
    • /
    • 제17권2호
    • /
    • pp.113-121
    • /
    • 1992
  • In order to estimate the pattern of medical care utilization and recognition for health factor among the inhabitants in Wan-do district which is located off the southern seashore from mainland Korea, household interview survey was performed from January 15 to 30, 1990 in Wan-do Gun area. The results observed were following: 1. Among the users of medical facilities 40.8% used public health facility as first contact facility. Lower the income level was and longer the residency duration was, the utilization rate of public health facilities was higher. By age groups and medical security status the utilization pattern was likely to disperse to local clinic and secondary contact medical resources. 2. Medical expense and access time were significantly different between primary contact and secondary contact medical resources. 3. Public health facility was recognized as the favoured institute having advantage of geographic and economic accessibility. 4. Statistically significant determinants in public health facility utilization among total medical service were the region, the medical expense, and the access time.

  • PDF

Spherical Particles Formation in Lubricated Sliding Contact -Micro-explosion due to the Thermally-activated Wear Process-

  • Kwon, O.K.
    • Tribology and Lubricants
    • /
    • 제11권5호
    • /
    • pp.1-9
    • /
    • 1995
  • The mechanism of various spherical particles formation from wide range of tribo-systerns is suggested and deduced by the action of micro-explosion on the basis of the thermally-activated wear theory, in which the flash temperature at contact could be reached clearly upto the material molten temperature due to the secondary activation energy from the exothermic reactions involving lubricant thermo-decomposition, metals oxidation, hydrogen reactions and other possible complex thermo-reactions at the contacts. Various shapes of spherical particles generated from the tribosystem can be explained by the toroidal action of micro-explosion accompanied with the complex thermo-chemical reactions at the contact surfaces or sub-surfaces.

3D Finite Element Analysis of Contact-less Power Supply with Linear Servo Motor

  • Woo, Kyung-Il;Park, Han-Seok;Park, Hyeong-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.190-196
    • /
    • 2007
  • This paper presents the 3D finite element analysis of the Contact-less Power Supply(CPS) with linear servo motor. The primary, secondary self and leakage inductances of the contact-less power supply and the capacitances of a resonant circuit are calculated by the finite element analysis using current source. The voltage source is used to do accurate analysis of the characteristics of the contact-less power supply. The CPS with the linear servo motor is proposed. The characteristics analysis of the contact-less power supply considering the linear servo motor is done.

Half-bridge 직렬공진 컨버터 적용 무접점 전원장치 효율특성 (Efficiency Characteristics of Half-bridge Series Resonant Converter for the Contact-less Power Supply)

  • 이현관;송환국;김은수;김윤호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.884-891
    • /
    • 2007
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss and the high voltage gain characteristics for load variations in contact-less power supply (CPS). To consider these characteristics, in this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is presented, described and verified through theoretical analysis, computer simulation and experimental test of 2.5kW prototype.

소음 스트레스가 면역반응에 미치는 영향에 관한 실험적 연구 (Effect of Sound Stress on Immune Response)

  • 김금재
    • 대한간호학회지
    • /
    • 제19권2호
    • /
    • pp.135-146
    • /
    • 1989
  • This study was undertaken to assess the effect of sound stress on humoral and cellular immune responses to thymus-dependent and independent antigens in mice. After mice were exposed to 4 hr daily sound stessors(83㏈) for 4 days before or after immunization, the primary and / or secondary immune response to sheep red blood cells(SRBC), polyvinylpyrroridone(PVP) or picry1 chloride(TNCB) were assayed. When mice were exposed to sound stressor before or after immunization, delayed-type hypersensitivity reaction and contact sensitivity to TNCB was remarkably depressed compared with those of the unstressed control mice. However, the primary and secondary hemagglutinin response of the stresed mice to SRBC showed a pronounced increase compared with that of the unstressed mice, In contrast to antibody response to SRBC, the primary antibody response of the stressed mic to PVP was almost not detected. surprisingly, the secondary antibody response to PVP of the mice receiving the secondary sound stress was markedly increased when the immune-depressed mice received the secondary immunization with PVP at 46 days after the primary immunization. The susceptibility of mice to intraven-oulsy infected Candida albicans was not changed by the sound stress.

  • PDF

Thermal Dissociation and Conformational Lock of Superoxide Dismutase

  • Hong, J.;Moosavi-Movahedi, A.A.;Ghourchian, H.;Amani, M.;Amanlou, M.;Chilaka, F.C.
    • BMB Reports
    • /
    • 제38권5호
    • /
    • pp.533-538
    • /
    • 2005
  • The kinetics of thermal dissociation of superoxide dismutase (SOD) was studied in 0.05 M Tris-HCl buffer at pH 7.4 containing $10^{-4}\;M$ EDTA. The number of conformational locks and contact areas and amino acid residues of dimers of SOD were obtained by kinetic analysis and biochemical calculation. The cleavage bonds between dimers of SOD during thermal dissociation and type of interactions between specific amino acid residues were also simulated. Two identical contact areas between two subunits were identified. Cleavage of these contact areas resulted in dissociation of the subunits, with destruction of the active centers, and thus, lost of activity. It is suggested that the contact areas interact with active centers by conformational changes involving secondary structural elements.

POWER TRANSMISSION CHARACTERISTICS OF FEASIBLE NON-CONTACT PICK-UP COIL COUPLED TO HIGH-FREQUENCY POWER SUPPLY SYSTEM

  • Kuroda, Mitsuyoshi;Tsuda, Masanori;Okuno, Atsushi;Gamage, Laknath;Mutsuo, Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.447-451
    • /
    • 1998
  • This paper conducts a study on a non-contact power delivering system using high-frequency inverter with the purpose of discussing the non-contact electric power transmission characteristics through circuit analysis, magnetic analysis and feasible experiments. In this power delivering scheme, various properties pertaining to the non-contact transformer of the power system such as the design, the core depth, core material, primary side frequency etc. are considered with a view of improving the non-contact power dilivery to the secondary.

  • PDF

질량비가 작은 접촉쌍성 GR Vir과 HV Aqr (SMALL MASS RATIO CONTACT BINARY GR Vir AND HV Aqr)

  • 오규동;김천휘;강영운;김호일;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권2호
    • /
    • pp.83-92
    • /
    • 2004
  • 질량비가 작은 접촉쌍성 GR Vir와 HV Aqr의 이미 발표된 분광 및 측광관측치를 WD프로그램에 적용하여 이 별들의 새로운 절대 물리량을 얻었다. GR Vir과 HV Aqr를 포함한 17개의 질량비가 작은 접촉쌍성들의 친화 상태를 조사하였다. 그 결과 질량비가 작은 접촉쌍성의 주성은 대부분 종년주계열상에 놓이며 반성은 영년주계열 아래 놓이고 있음을 확인하였다.