Non contact Coupler Design in Non contact Power Supply

비접촉 전원장치의 비접촉 커플러 설계

  • Ryu, M.H. (Korea Electrotechnology Research Institute) ;
  • Cha, H.N. (Korea Electrotechnology Research Institute) ;
  • Baek, J.W. (Korea Electrotechnology Research Institute)
  • Published : 2005.07.18

Abstract

In this paper, the electrical characteristics of the non-contact transformer is presented using conventional coupled inductor theory. Each non-contact transformer is analyzed through simulation and measurement. In high power applications, non-contact transformer is so bulky and heavy that it should be split by some light transformers. So non-contact transformer needs several small transformer modules which are connected series or parallel to transfer the primary power to the secondary one. This paper shows analytic result of the each non-contact transformer module and comparison result between series-connection and parallel-connection of the non-contact transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.

Keywords