• 제목/요약/키워드: secondary beam

검색결과 306건 처리시간 0.029초

Measurement of Defect Energy Level in MgO Layer

  • Son, Chang-Gil;Song, K.B.;Jeoung, S.J.;Park, E.Y.;Kim, J.S.;Choi, E.H.;J, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1380-1383
    • /
    • 2007
  • The secondary electron emission coefficient (${\gamma}$) of the cathode is an important factor for improving the discharge characteristics of AC-PDP, because of its close relationship to discharge voltage. In this experiment, we have investigated the electronic structure of the energy band in the MgO layer responsible for the high ${\gamma}$. We used three kinds of MgO pellet that have another component, and each MgO layers have been deposited by electron beam evaporation method. The work-functions of MgO layer have been investigated from their ion-induced secondary electron emission coefficient (${\gamma}$), respectively, using various ions with different ionization energies in a ${\gamma}-FIB$ (Focused Ion Beam) system. We have compared work-function with ${\gamma}-FIB$ system current signal for measurement defect energy level in MgO layer. MgO-A in the three types has lowest work-function value (4.12eV) and there are two defect energy levels.

  • PDF

Oxygen Ion Beam Assisted Deposition법에 의해 형성된 AC PDP용 MgO 보호막의 특성 연구 (Study of a MgO Protective Layer Deposited with Oxygen Ion Beam Assisted Deposition in an AC PDP)

  • 권상직;이조휘
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.615-619
    • /
    • 2007
  • MgO layer plays an important role for plasma display panels (PDPs). In this experiment, ion beam assisted deposition (IBAD) methode was uesed to deposit a MgO thin film and the assisting oxygen ion beam energy was varied from 100 eV to 500 eV. In order to investigate the relationship between the secondary electron emission and the defect levels of the MgO layer, we measured the cathodoluminescence (CL) spectra of the MgO thin films, and we analyzed the CL peak intensity and peak transition. The results showed that the assisting ion beam energy played an important role in the peak intensity and the peak transition of the CL spectrum. The properties of MgO thin film were also analyzed using XRD and SEM, these results showed the assisting ion beam energy had direct effect on characteristics of MgO thin film.

Measurement of Secondary Electron Emission Coefficient and Bimolecular Valence Band Energy Structure of Erythrocyte with and Without Bioplasma Treatment

  • Lee, Jin-Young;Baik, Guyon;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.483-483
    • /
    • 2012
  • Recently, nonthermal bioplasma has been attracted by researchers due to their potentials to modulate cellular functions resulting in changes of biomolecular electron band structures as well as cell morphologies. We have investigated the secondary electron emission characteristics from the surface of the erythrocyte, i.e., red blood cell (RBC) with and without the nonthermal bioplasma treatment in morphological and biomolecular aspects. The morphologies have been controlled by osmotic pressure and biomolecular structures were changed by well known reactive oxygen species. Ion-induced secondary electron emission coefficient have been measured by using gamma-focused ion beam (${\gamma}$-FIB) system, based on the quantum mechanical Auger neutralization theory. Our result suggests that the nonthermal bioplasma treatment on biological cells could result in change of the secondary electron emission coefficient characterizing the biomolecular valence band electron energy structures caused by the cell morphologies as well as its surface charge distributions.

  • PDF

An Assessment of the Secondary Neutron Dose in the Passive Scattering Proton Beam Facility of the National Cancer Center

  • Han, Sang-Eun;Cho, Gyuseong;Lee, Se Byeong
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.801-809
    • /
    • 2017
  • The purpose of this study is to assess the additional neutron effective dose during passive scattering proton therapy. Monte Carlo code (Monte Carlo N-Particle 6) simulation was conducted based on a precise modeling of the National Cancer Center's proton therapy facility. A three-dimensional neutron effective dose profile of the interior of the treatment room was acquired via a computer simulation of the 217.8-MeV proton beam. Measurements were taken with a $^3He$ neutron detector to support the simulation results, which were lower than the simulation results by 16% on average. The secondary photon dose was about 0.8% of the neutron dose. The dominant neutron source was deduced based on flux calculation. The secondary neutron effective dose per proton absorbed dose ranged from $4.942{\pm}0.031mSv/Gy$ at the end of the field to $0.324{\pm}0.006mSv/Gy$ at 150 cm in axial distance.

주사 전자 현미경에서 영상 획득에 필요한 구성 요소 구현 (Realization for Each Element for capturing image in Scanning Electron Microscopy)

  • 임선종;이찬홍
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.26-30
    • /
    • 2009
  • Scanning Electron Microscopy (SEM) includes high voltage generator, electron gun, column, secondary electron detector, scan coil system and image grabber. Column includes electron lenses (condenser lens and objective lens). Condenser lens generates fringe field, makes focal length and control spot size. Focal length represents property of lens. Objective lens control focus. Most of the electrons emitted from the filament, are captured by the anode. The portion of the electron current that leaves the gun through the hole in the anode is called the beam current. Electron beam probe is called the focused beam on the specimen. Because of the lens and aperture, the probe current becomes smaller than the beam current. It generate various signals(backscattered electron, secondary electron) in an interaction with the specimen atoms. In this paper, we describe the result of research to develop the core elements for low-resolution SEM.

  • PDF

박스형 보강효과를 고려한 개선된 PSC Beam교의 구조 안전성 평가에 관한 연구 (A Study on Structural Safety Evaluation of Improved PSC Beam Bridges Considering To-Box Reinforcement Effect)

  • 한성호;신재철;방명석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권5호
    • /
    • pp.197-211
    • /
    • 2007
  • 노후화된 PSC Beam 교량은 개선된 보강방안이 필요하다. 본 연구에서는 성능저하가 발생된 노후 PSC Beam 교량을 대상으로 PSC Beam 교량의 보강형을 폐단면 박스형태로 변환하여 이차합성 구조화함으로써, PSC Beam 교량의 강성을 안정적으로 증가시킬 수 있는 박스형 보강방안을 제안하였다. 제안된 보강방안과 기존의 외부프리스트레스 도입공법을 결합하여 보강할 경우, 보강효과를 정량적으로 규명하기 위해 시공단계해석에 따른 시간 의존적 정밀해석을 수행하였다. 성능개선을 위해 제안된 박스형 보강방안 적용 시 보강방법에 따라 전단면 및 휨 보강과 같은 다양한 형태의 보강방안을 제시한 후, 각각의 보강방안에 대해 이차합성 효과에 따른 상향캠버 및 부재응력 특성을 평가하였다. 또한 내하력 평가를 수행하여 내하율을 검토함으로서, 개선된 PSC Beam 교량의 구조 안전성을 정량적으로 평가하였다.

2차 가스분사에 의한 원추형 로켓노즐 추력벡터제어 성능해석 (I) (Performance Analysis of Secondary Gas Injection for a Conical Rocket Nozzle TVC(I))

  • 김형문;이상길;윤웅섭
    • 한국추진공학회지
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 1999
  • 풍전압력비와 2차 제트 분사구 위치에 따른 2차분사 추력방향 제어(SITVC: secondary injection thrust vector control) 성능특성 변화를 수치해석하였다. 2차 제트 분사에 의해 간섭된 수축-팽창노즐 내부의 초음속유동장을 대상으로 3차원 비정상 오일러 방정식을 내재적으로 근사인자분해된 Beam과 Warming의 방법을 사용하여 차분하였으며, 2차 분사 제트에 의한 추력비 비추력비 및 전향각에 대한 성능변화를 고찰하였다. 연구결과 측추력과 비추력비는 2차 분사 질량유량에 비래하여 증가하는 반면, 비추력 성능은 감소되어 2차 분사 질량유량이 적을 수록 추력 성능손실이 적어지는 것으로 나타났다. 또한 동일한 전압력비에 대하여 2차 제트 분사위치가 노즐의 하류에 위치할수록 고속기 주유동과의 간섭에 의한 강한 충격파로 인하여 측추력과 측비추력의 증가와 함께 추력방향 제어성능이 향상됨을 알 수 있었다.

  • PDF

굽힘 하중을 받는 두꺼운 채널 빔의 해석 (Analysis of Thick-walled Composite Channel Beam Under Flexural Loading)

  • 최용진;전흥재;변준형
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.69-73
    • /
    • 2003
  • A open section thick composite beam model is suggested in this study. In the model, the primary and secondary warping and transverse shear effects are incorporated. The rigidities associated with thick channel composite beam and thin channel composite beam are obtained and compared. The results show that the difference among rigidities of the thick and thin composite beams increase as the wall thickness increases.

  • PDF