• Title/Summary/Keyword: second harmonic

Search Result 603, Processing Time 0.025 seconds

Improved Randomized Pulse Position PWM Scheme Based on The three-phase Indui Drive To Reduce the Harmonic Effect (개선된 Randomized Pulse Position PWM기법을 이용한 3상 유도 전동기의 고조파 영향)

  • Ha, Sang-Mok;Han, Woo-Yong;Lee, Chang-Goo;Kim, Byung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1169-1171
    • /
    • 2002
  • In this paper, RFRPP(Random Frequency Randomized Pulse Position ) PWM for three-phase voltage-controlled inverters is proposed. The LLPWM(Lead-Lag PWM) techinquc is that three switching pulses are located randomly back and forth in each switching interval. But with the restriction of random distribution, the harmonic spectrum cannot be dispersedly and continuously distributed. This paper calculates the duty ratio of the switching pulse firstly. Second, the switching pulses are located randomly in the switching interval. Third, the fixed switching frequency of the space vector modulation is randomly varied. To verify the validity of the proposed technique, simulation study is tried using Matlab/Simulink. When a proposed techniquc is employed, the harmonic spectrum of the inverter output voltagc varies from one cycle to the next and the EMI(Electromagnetic Interference) and resonant vibration are greatly alleviated.

  • PDF

An Experimental Study on the 2nd,3rd Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (밀폐관형과 개방관형 열음향 냉동기의 2차, 3차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;박영선
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.193-196
    • /
    • 2002
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In order to determine the optimum resonant tube length and the frequency, the open-tube-type(3$\lambda$/4) and close- tube - type (2$\lambda$/2) thermoacoustic refrigerator were constructed. In third harmonic, the temperature difference of 3$\lambda$/4 refrigerator was $53^{\circ}C$(resonator length :400mm). In second harmonic, the temperature difference of 2$\lambda$/2 refrigerator was $51^{\circ}C$(resonator length :400mm).

  • PDF

Harmonic Suppression and Broadening Bandwidth of Band Pass Filter Using Aperture and Photonic Band Gap Structure

  • Seo, Chul-Hun
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.4
    • /
    • pp.208-212
    • /
    • 2005
  • In this paper, we introduced a band-pass filter employed the PBG structure and the aperture on the ground together. The harmonics of band pass filter have been suppressed by employing the PBG structure and the bandwidth of it has been broadened by using the aperture on the ground. The designed PBG cells have three different sizes. The largest cells, the middle cells, and the smallest cells have suppressed the multiple of second harmonics, the multiple of third harmonics, and the multiple of fifth harmonics, respectively. The center frequency has been 2.18 GHz. The bandwidth has been increased from 230 MHz up to 310 MHz(80 MHz, about $35\%$) by the aperture and the ripple characteristics in passband have been improved and the harmonic frequencies have been suppressed about 30 dB by the PBG.

Advanced Protective Relaying Algorithm by Flux-Differential Current Slope Characteristic for Power Transformer (전력용 변압기용 자속-차전류 기울기 특성에 의한 개선된 보호계전 알고리즘)

  • 박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.382-388
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of power transformers is current percentage differential relaying(PDR). However, the harmonic components could be decreased by magnetizing inrush when there have been changes to the material of iron core or its design methodology. The higher the capacitance of high voltage status and underground distribution, the more differential current includes the second harmonic component during occurrence of an internal fault. Therefore, the conventional harmonic restraint methods need modification. This paper proposes an advanced protective relaying algorithm by fluxt-differential current slope characteristic and trend of voltage and differential current. To evaluate the performance of proposed algorithm, we have made comparative studies of PDR fuzzy relaying, and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP99, and data collection is made through simulation of various internal faults and inrush. As the results of test. the new proposed algorithm was proven to be faster and more reliable.

Multi-harmonic Suppression Band-Pass Filter for Communication System

  • Zhang, Wenmei;Han, Liping;Ma, Runbo;Mao, Junfa
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.533-535
    • /
    • 2007
  • For the purpose of decreasing intermodulation distortion, a new multi-harmonic suppression band-pass filter based on a microstrip radial stub is studied. Compared with traditional resonator filters, the new filter can suppress the second, third, and even fourth harmonics directly. The dimension of the filter is about $0.3\;{\lambda}_{g^0}{\times}0.13\;{\lambda}_{g^0}$ (${\lambda}_{g^0}$ is the guiding wavelength at the resonant frequency). Only one gap was introduced, so lower insertion loss can be obtained. Basic agreement between the measured and simulated results has been achieved.

  • PDF

Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients

  • Kang, Dong-Hyeok;Kim, Hyung-Kyu;Park, Jun-Kyu;Hyun, Seung-Ho;Hur, Jin
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.48-56
    • /
    • 2016
  • This paper proposes a method for detecting irreversible demagnetization using the harmonic analysis of back electromotive force (BEMF) in interior permanent magnet-type brushless DC motors. First, demagnetization patterns, such as equality, inequality, and weighted demagnetizations, are defined and classified by considering the possibility of demagnetization resulting from motor operating characteristics. Second, an available diagnostic model for the harmonic analysis of BEMFs is defined according to pole-slot coefficients because the characteristics of BEMFs under demagnetization conditions are affected by the combination of poles and slots. Third, BEMFs and their harmonic components under normal and demagnetization conditions are analyzed through simulation and experiment to verify the proposed demagnetization detection technique.