Cabin Noise Reduction of a Maglev Train (자기부상열차의 소음저감)

  • 김현실;김재승;강현주;강현주;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.849-854
    • /
    • 2001
  • Cabin noise reduction in maglev trains developed by KIMM is studied. Based on the measurements of cabin noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources is investigated, efficient noise reducing methods are studied such as STL increasement of floor panels, sealing, and absorption treatment. It is found that the most important noise sources are VVVF inverter and SLIM in running condition. Since the noise sources are under the cabin floor, complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction. After polyurethan form (50t) is added for more sound absorption and sealing treatment, the cabin noise is reduced by 3-4 ㏈.

  • PDF

Electrical and Optical Characteristics of Plasma Display Panel Fabricated by Vacuum In-line Sealing (진공 인라인 실장에 의해 제작된 플라즈마 디스플레이 패널의 전기적ㆍ광학적 특성)

  • Park, Sung-Hyun;Lee, Neung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.344-349
    • /
    • 2005
  • The optical and electrical characteristics of plasma display panel(PDP) using the vacuum in-line sealing technology compared with the conventional sealing process in this research. This PDP consisted of MgO protecting layer by e-beam evaporation and battier rib, transparent dielectric layer, dielectric layer, and electrodes by screen printer and then sealed off on Ne-Xe(4 %) 400 Torr and 430。C. The brightness and luminous efficiency were good as the base vacuum level was higher, and it was to check the advantage of high vacuum level sealing, one of the strong points of the vacuum in-line sealing process. However, the brightness and luminous efficiency was dropped sharply because of a crack on MgO protecting layer by the difference of the expansion and contraction stress on high temperature in the vacuum states between MgO and substrate. Fortunately, the crack was prevented by MgO was deposited on higher temperature than 300。C. Finally, the PDP, was fabricated by the vacuum in-line sealing process, resulted the lower brightness than processing only the thermal annealing treatment in the vacuum chamber, but the luminous efficiency was increased by the reducing power consumption with the decreasing luminous current. The vacuum in-line sealing technology was not to need the additional thermal annealing process and could reduce the fabrication process and bring the excellent optical and electrical properties without the crack of MgO protecting layer than the conventional sealing process.

Evaluation of physical properties of Zn-Al metal coating according to arc metal spray surface treatment method (아크 금속 용사 표면 처리 방법에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가)

  • Jang, Jong-Min;Kim, Yeung-Kwan;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.89-90
    • /
    • 2022
  • Arc metal spraying is a widely used method for improving the performance of construction structures such as corrosion resistance and electromagnetic wave shielding. However, when arc metal spraying is applied to a concrete structure, adhesion performance may deteriorate. Therefore, the effect of each surface treatment method on the physical properties between the arc metal spray coating and concrete was reviewed by evaluating the deposition efficiency and adhesion performance according to the arc metal spray surface treatment method (surface reinforcing agent, roughening agent, and sealing agent). As a result, it is suggested as an optimal surface treatment condition to induce non-interface failure by using a roughening agent and to improve the properties of concrete and metal coatings by applying a surface reinforcing agent and sealing agent.

  • PDF

Microwave Sealing of Alumina Substrate with Sealing Glass (봉착용 유리를 이용한 알루미나 기판의 마이크로파 봉착)

  • Park, Seong-Su;Cha, Mu-Gyeong;Ryu, Bong-Gi;Sin, Hak-Gi;Park, Chan-Yeong;Min, Seong-Gi;Min, Seong-Gi
    • Korean Journal of Materials Research
    • /
    • v.9 no.2
    • /
    • pp.149-154
    • /
    • 1999
  • Alumina substrate was sealed by PbO-ZnO-$B_2O_3$glass using microwave heating. The crystallization behaviour of sealing glass and the state of sealing joint were investigated and were compared with those of conventionally sealed one. Compared to the conventional one, the microwave heat-treated sample had well-grown $\textrm{PbTiO}_3$ crystals and high degree of crystallinity even though it had shorter heat-treatment time and lower heat-treatment temperature. Also, the microwave sealed sample exhibited relatively a good sealing state and almost same bending strength.

  • PDF

COMPARATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS TEMPORARY SEALING MATERIALS (근관와동 가봉재 종류에 따른 변연누출의 비교 분석)

  • Yun, Chang;Hong, Suck-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.151-157
    • /
    • 1991
  • The roles of temporary sealing materials used in endodontics are impotant Especially, its marginal sealing properties affect endodontic success and failure in endodontic treatment The purpose of this in vitro study was to compare and evaluate the marginal sealing properties of various temporary restorative materials used in endodontic access cavity by using electrochemical method. Standard endodontic access cavities were prepared in extracted human molar teeth and filled with Caviton, IRM, zinc oxide - eugenol cement. Each specimen was immersed in 1 % solution of KCl, and applied a potential of 9 V external power supply. Marginal microleakage and water sorption were measured for marginal sealing effect evaluation in comparison with each group. A comparative study of the obtained results have led to the following conclusions. 1. The Caviton group showed lower marginal microleakage value than the zinc oxide - eugenol cement and IRM group the 6 th day after. The IRM group showed lwoer marginal microleakage value than the zinc oxide - eugenol cement group from the 6 th day to the 12 th day. But there was no significant difference between zinc oxide - eugenol cement and IRM group after the 13 th day. 2. As time went by, marginal microleakage value was increased in Caviton, IRM and zine oxide - eugenol cement.

  • PDF

Comparison of ventilation effects by mask-sealing methods during bag-valve-mask ventilation (백-밸브-마스크 환기 시 마스크 밀착방법에 따른 환기효과 비교)

  • Lee, Nam-Jong;Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.73-82
    • /
    • 2018
  • Purpose: The purpose of this study was to compare the tidal volumes and airway pressures of 3 mask-sealing methods (one hand C-E, two hands C-E, and one hand O-E) for ventilation treatment. Methods: The study subjects were 45 paramedic students. Tidal volume was measured for the three sealing methods by setting a ventilator, connecting it to the masks for 2 minutes, and using Respi-trainer software. Results: Regarding general characteristics, the group of men, in upper grades, and with practical training experience and experience and experience in the implementation of bag-valve-mask ventilation provided higher tidal volumes. Regarding physical characteristics, larger hands and greater grip strength correlated with higher tidal volume. Two hands C-E generated the highest tidal volume of $483.78{\pm}34.14mL$, one hand O-E generated $449.59{\pm}51.09mL$ and one hand C-E generated $394.31{\pm}68.95mL$. Conclusion: Means of tidal volumes were statistically significantly different based on mask sealing methods (p<.001). Two hand C-E was performed by the two-persons task and was suggested as the most effective method. For the one-person task, one hand O-E was the more effective method compared to the previous one hand C-E.

Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws (임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the preload maintenance of the retaining screw when using anaerobic sealing agents in implant fixture and abutment components. Specifically, the study examines the effects of anaerobic sealing agents on different types of screws. Materials and methods: External hexagon implants made of titanium and anti-rotational abutments were used. Titanium abutment screws and ebony abutment screws from the same manufacturer were used. The experiment was divided into four groups (n = 10 in each group). In the control group, no sealing agent was used at the implant fixture and abutment screw interface. All abutment screws were tightened according to the manufacturer's recommended torque (30 N.cm). After 24 hours, the removal torque (detorque) of each screw was measured using a digital torque gauge device. The data were analyzed by two-way ANOVA test according to normality distribution satisfaction. Results: Looking at the results for each group, titanium screws and no treatment showed detorque values of 20.3 ± 1.6 N.cm. titanium screws and applied anaerobic sealing agent showed detorque values of 32.4 ± 6.7 N.cm. Ebony screws and no treatment showed detorque values of 20.2 ± 1.5 N.cm. ebony screws and applied anaerobic sealing agent showed detorque values of 30.4 ± 4.5 N.cm. Conclusion: The detorque value was higher in the case of using anaerobic sealing agents in both the titanium screw and ebony screw groups. But there was no difference between the two screws.

EVALUATION OF THE EFFECTIVENESS OF THERAPEUTIC SEALING ACCORDING TO THE LESION DEPTHS OF PROXIMAL EARLY CARIES (인접면 초기 우식 병소의 깊이에 따른 therapeutic sealing의 유효성 평가)

  • Lee, Geum-Lang;Ahn, Myung-Ki;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.394-403
    • /
    • 2009
  • As the minimally invasive approach against white spot like early caries lesions in proximal surfaces of the teeth, therapeutic sealing has been introduced and studied for effective materials and methods to arrest the early caries lesion effectively, which is still going on. This study was performed for the purpose of evaluating its validity for the non-cavitated lesions according to the depth from surface using therapeutic sealing followed by artificial caries induction and evaluation with micro-CT, and we obtained the results as follows. 1. It was revealed that the deeper the caries lesions are, the lower radiation intensity at lesion body areas in pre-treatment specimen. 2. In the sealed groups, there were no differences in radiation intensity between pre- and post-treatment, whereas there were significant decreases in unsealed groups(p<0.05). 3. Even in the specimens with the lesions reaching deeply into DEJ, the effect of sealing was significant(p<0.05). Conclusively, it was thought therapeutic sealing can be an effective tool against the early caries lesions, regardless of their depth into tooth, unless cavitated.

  • PDF

The Effect of Porosity Sealing by Sol-gel Method on Physical and Electrical )Properties of a Plasma Sprayed $Ce_0.8Gd_0.2O_2$ Electrolyte (졸-겔법에 의한 기공 충전이 플라즈마 용사된 $Ce_0.8Gd_0.2O_2$ 전해질체의 물리 및 전기적 성질에 미치는 영향)

  • 유석원;김장엽;김호무;김병호;임대순
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.11
    • /
    • pp.1205-1210
    • /
    • 1999
  • Ceria based electrolytes were fabricated by a plasma spraying method. The porosity which was crated during the plasma spraying process was infiltrated with Ce0.8Gd0.2O2 sol by ultrasonic treatment and heat treatment at 90$0^{\circ}C$ in order to improve physical and electrical properties. The porosity decreased from 9.8% to 6.5% and gas permeability at 80$0^{\circ}C$ decreased from 16.7$\times$10-3 to 5.7$\times$10-3 cm3(STP)/cm2.s.cmHg as the number of treatment increased 10 cycles. The ionic conductivity was also increased about 30% after 10 times of sealing.

  • PDF

A Study Interior Noise Reduction of a Maglev Train at Low Speed (저속 주행시 자기부상열차의 실내소음저감에 관한 연구)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.7
    • /
    • pp.253-260
    • /
    • 2001
  • A Study of interior noise reduction in the magelv train is presented. Tarin speed of interest is low such that aero-dynamic noise is negligible and power supply system is a dominant noise source. Based on the measurements of interior noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources are investigated several noise reducing methods are studied such as STL increasement of floor panels. sealing. and absorption treatment It is found that the most important noise sources are VVVF inverter and SLM in running condition, whereas air conditioner and DC/DC converter are dominant in zero speed. Sine the major noise sources are under the floor complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction After sound absorbing material, which is polyurethan foam of 50 mm thickness, is thickness, is attached to the downward side of the floor in addition to sealing treatment, the interior noise is reduced by 3~4 dB.