• Title/Summary/Keyword: sealer

Search Result 216, Processing Time 0.028 seconds

Micro-computed tomographic evaluation of single-cone obturation with three sealers

  • Sahar Zare;Ivy Shen;Qiang Zhu;Chul Ahn;Carolyn Primus;Takashi Komabayashi
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.25.1-25.12
    • /
    • 2021
  • Objectives: This study used micro-computed tomography (µCT) to compare voids and interfaces in single-cone obturation among AH Plus, EndoSequence BC, and prototype surface pre-reacted glass ionomer (S-PRG) sealers and to determine the percentage of sealer contact at the dentin and gutta-percha (GP) interfaces. Materials and Methods: Fifteen single-rooted human teeth were shaped using ProTaper NEXT size X5 rotary files using 2.5% NaOCl irrigation. Roots were obturated with a single-cone ProTaper NEXT GP point X5 with AH Plus, EndoSequence BC, or prototype S-PRG sealer (n = 5/group). Results: The volumes of GP, sealer, and voids were measured in the region of 0-2, 2-4, 4-6, and 6-8 mm from the apex, using image analysis of sagittal µCT scans. GP volume percentages were: AH Plus (75.5%), EndoSequence BC (87.3%), and prototype S-PRG (94.4%). Sealer volume percentages were less: AH Plus (14.3%), EndoSequence BC (6.8%), and prototype S-PRG (4.6%). Void percentages were AH Plus (10.1%), EndoSequence BC (5.9%), and prototype S-PRG (1.0%). Dentin-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 82.4% ± 6.8%, 71.6% ± 25.3%, and 70.2% ± 9.4%, respectively. GP-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 65.6% ± 29.1%, 80.7% ± 25.8%, and 87.0% ± 8.6%, respectively. Conclusions: Prototype S-PRG sealer created a low-void obturation, similar to EndoSequence BC sealer with similar dentin-sealer contact (> 70%) and GP-sealer contact (> 80%). Prototype S-PRG sealer presented comparable filling quality to EndoSequence BC sealer.

EXPERIMENTAL STUDY on SEALING QUALITY OF KERR SEALER AS ROOT CANAL SEALERS (Kerr sealer를 근관충전재(根管充塡材)로 사용시(使用時) 근관폐쇄성(根管閉鏁性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.77-81
    • /
    • 1980
  • The author has studied comparatively the sealing quality of conventional Z.O.E. cement, Kerr sealer and Nogenol sealer by means of penetration of 2% methylene blue solution through the root apex of human teeth in 72 cases as time elapsed. The results were as follows; 1. All the specimens, whose dye immersion time is two days, showed dye penetration of low degree unrelated to the kinds of root canal sealer. 2. Kerr sealer group, like conventional Z.O.E. group, showed dye penetration of high degree related to increased time of immersion in the dye. 3. In Nogenol group, there was slight increase in penetration related to increased time of immersion in the dye. 4. Kerr sealer group showed comparatively lower grade of dye penetration than conventional Z.O.E. and higher than Nogenel sealer.

  • PDF

EFFECT OF IRRIGATION METHODS ON THE ADHESION OF RESILON/EPIPHANY SEALER AND GUTTA-PERCHA/AH 26 SEALER TO INTRACANAL DENTIN (근관 세척법이 Resilon/Epiphany sealer와 Gutta-percha/AH 26 sealer의 근관 상아질과의 접착에 미치는 영향)

  • Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.98-106
    • /
    • 2008
  • The purpose of this study was to evaluate whether intracanal irrigation method could affect the adhesion between intracanal dentin and root canal filling materials (Gutta-percha/AH 26 sealer and Resilon/Epiphany sealer). Thirty extracted human incisor teeth were prepared. Canals were irrigated with three different irrigation methods as a final rinse and obturated with two different canal filling materials (G groups: Gutta-percha/AH 26 sealer, R groups: Resilon/Epiphany sealer) respectively. Group G1, R1-irrigated with 5.25% NaOCl Group G2, R2-irrigated with 5.25% NaOCl, sterile saline Group G3, R3-irrigated with 5.25% NaOCl, 17% EDTA, sterile saline Thirty obturated roots were horizontally sliced and push-out bond strength test was performed in the universal testing machine. After test, the failure patterns of the specimens were observed using Image-analyzing microscope. The results were as follows. 1. Gutta-percha/AH 26 sealer groups had significantly higher push-out bond strength compared with the Resilon/Epiphany sealer groups (p < 0.05). 2. Push-out bond strength was higher when using 17% EDTA followed by sterile saline than using NaOCl as a final irrigation solution in the Resilon/Epiphany sealer groups (p < 0.05). 3. In the failure pattern analysis, there was no cohesive failure in Group G1, G2, and R1. Gutta-percha/AH 26 sealer groups appeared to exhibit predominantly adhesive and mixed failure patterns, whereas Resilon/Epiphany sealer groups exhibited mixed failures with the cohesive failure occurred within the Resilon substrate.

THE EFFECT OF CONSISTENCY OF SEALER ON CANAL OBTURATION IN INJECTION-THERMOPLASTICIZED GUlTA-PERCHA METHOD (연화(軟化) Gutta-percha 충전법(充塡法)에서 Sealer의 조도(稠度)가 근관폐쇄(根管閉鎖)에 미치는 영향(影響))

  • Lee, Young-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.38-48
    • /
    • 1989
  • The purpose of this study was to investigate the proper consistency of root canal sealer needed in obtaining an efficient canal obturation in injection-thermoplasticized low-temperature ($70^{\circ}C$) gutta-percha method. The sealer was made by incorporating zinc oxide powder into $0.5m{\ell}$ of eugenol and then the $0.5m{\ell}$ of mixture slurry was placed between two flat glass plates. The consistency was determined by measuring the degree of spread of the slurry at loading the 120gm of weight from the top plate. The sealer was prepared according to P/L ratio corresponding to the acquired consistency of 65.45mm, 46.80mm, 28.95mm and 22.60mm. The distal roots were obtained by cutting off from 125 extracted human lower molars and the root canals were prepared by using step-back method. The prepared canals were coated with the sealers on their walls and obturated by using the injection-thermoplasticized low-temperature ($70^{\circ}C$) gutta-percha method. All specimens were immersed in 2% methylene blue dye solution for 48 hours at $37^{\circ}C$. Calipers was used to measured the dye penetration into the root canals from apical constrictions. The results were as follows : The canals obturated without sealer showed significantly more leakage than the canals obturated with sealer. Within the consistency from 65.45mm to 22.60mm, the sealer of 65.45mm appeared significantly better than that of 28.95mm and 22.60mm in the canals obturated by injection-thermoplasticized gutta-percha method, and better than that of 46.80mm without statistical significance.

  • PDF

A STUDY ON THE CYTOTOXICITY OF THE ROOT CANAL SEALERS (근관충전용(根管充塡用) sealer의 세포독성(細胞毒性)에 관한 연구(硏究))

  • Lee, Seung-Jong;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.25-40
    • /
    • 1991
  • Four root canal sealers, Apatite Root Sealer I and II composed mainly of hydroxyapatite/tricalciumphosphate, Sealapex containing calcium hydroxide, and Roth Sealer composed of zinc oxide - eugenol were compared on the culture of L929 fibroblasts. MIT (Methyl Thiazole Tetrazolium Bromide) colorimetric technique was used to measure the mitochondrial dehydrogenase activity. Results were as follows: 1. Hydroxyapatite/tricalcium phosphate mixed sealers were significantly less toxic compared with calcium hydroxide and zinc oxide - eugenol type sealers. High pH of the calcium hydroxide sealer and release of eugenol component from the zinc oxide - eugenol type sealer were presumed to be the cause of the toxicity of these two sealers. In no cases, there were more cytoblastic effects in hydroxyapatite/tricalcium phosphate mixed sealers compared to the control groups. 2. In all experimental groups, toxicity was decreased as dilutions were increased. However in zinc oxide-eugenol type sealer the cell activity was weakened for all dilution groups. 3. Regarding the effect of setting time, Apatite I and Sealapex were less toxic as the setting progressed. Apatite II kept constant regardless of the different time ellapsed after setting but Roth sealer revealed significantly higher toxicity for all experimental groups. 4. Comparing two different culture periods of 24 hours and 72 hours, Apatite I showed higher cell activities in longer period(72 hours) while Apatite II did not. Sealapex and Roth sealer, however, showed significantly lower cell activities in longer period.

  • PDF

APICAL SEALING OF THERMAFIL OBTURATORS IN CURVED CANALS (만곡근관에서 Thermafil의 근단폐쇄성에 관한 실험적 연구)

  • Ha, Joo-Hee;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.671-684
    • /
    • 1995
  • The purpose of this study was to compare the apical sealing ability, overfilling and obturation of lateral canals using two gutta-percha techniques: Thermafil obturators and cold lateral condensation. Eighty numbered epoxide blocks with one major and five lateral canals were divided into four experimental groups and obturated according to experimental groups. Four experimental groups were as follows: Group 1 : Filling with Thermafil plastic obturators and sealer(ThermaSeal) Group 2 : Filling with Thermafil plastic obturators only, without sealer(ThermaSeal) Group 3 : Fillng using lateral condensation with sealer(AH-26) Group 4 : Fillng using lateral condensation without sealer(AH-26) All the blocks were stored in 100% relative humidor at room temperature for 7 days. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye penetration in millimeter under a stereoscope. The length of gutta-percha and sealer in each of the lateral canals was measured, too. The presence or absence of overfilling of gutta-percha and sealer was recorded. The data was analyzed by one-way ANOVA. The obtained results were as follows: l. Apical dye leakage was almost: not occurred in Group Willed with Thermafil and sealer) and Group 3(filled using lateral condensation with sealer), and there was no significant difference in linear leakage between two groups(p>0.01). 2. In both Thermafil and lateral condensation groups, linear leakage of Group I, 3(filled with sealer) was less than that of Group 2, 4(filled without sealer), and there was no significant difference in linear leakage between Group 1, 2, 3(p> 0.01). 3. Overfilling during obturation of Group 1, 2(filled with Thermafil) was more than Group 3, 4(filled using lateral condensation), and there was no significant difference between groups(p> 0.05). 4. Groups filled with Thermafil had significantly more gutta-percha than groups filled using lateral condensation in all lateral canals(p <0.01), the total length of gutta-percha and sealer found in all lateral canals were similar in Group 1 and Group 3.

  • PDF

Retreatability of two endodontic sealers, EndoSequence BC Sealer and AH Plus: a micro-computed tomographic comparison

  • Oltra, Enrique;Cox, Timothy C.;LaCourse, Matthew R.;Johnson, James D.;Paranjpe, Avina
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: Recently, bioceramic sealers like EndoSequence BC Sealer (BC Sealer) have been introduced and are being used in endodontic practice. However, this sealer has limited research related to its retreatability. Hence, the aim of this study was to evaluate the retreatability of two sealers, BC Sealer as compared with AH Plus using micro-computed tomographic (micro-CT) analysis. Materials and Methods: Fifty-six extracted human maxillary incisors were instrumented and randomly divided into 4 groups of 14 teeth: 1A, gutta-percha, AH Plus retreated with chloroform; 1B, gutta-percha, AH Plus retreated without chloroform; 2A, gutta-percha, EndoSequence BC Sealer retreated with chloroform; 2B, gutta-percha, EndoSequence BC Sealer retreated without chloroform. Micro-CT scans were taken before and after obturation and retreatment and analyzed for the volume of residual material. The specimens were longitudinally sectioned and digitized images were taken with the dental operating microscope. Data was analyzed using an ANOVA and a post-hoc Tukey test. Fisher exact tests were performed to analyze the ability to regain patency. Results: There was significantly less residual root canal filling material in the AH Plus groups retreated with chloroform as compared to the others. The BC Sealer samples retreated with chloroform had better results than those retreated without chloroform. Furthermore, patency could be re-established in only 14% of teeth in the BC Sealer without chloroform group. Conclusion: The results of this study demonstrate that the BC Sealer group had significantly more residual filling material than the AH Plus group regardless of whether or not both sealers were retreated with chloroform.

Development of an FPGA-based Sealer Coating Inspection Vision System for Automotive Glass Assembly Automation Equipment (자동차 글라스 조립 자동화설비를 위한 FPGA기반 실러 도포검사 비전시스템 개발)

  • Ju-Young Kim;Jae-Ryul Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.320-327
    • /
    • 2023
  • In this study, an FPGA-based sealer inspection system was developed to inspect the sealer applied to install vehicle glass on a car body. The sealer is a liquid or paste-like material that promotes adhesion such as sealing and waterproofing for mounting and assembling vehicle parts to a car body. The system installed in the existing vehicle design parts line does not detect the sealer in the glass rotation section and takes a long time to process. This study developed a line laser camera sensor and an FPGA vision signal processing module to solve this problem. The line laser camera sensor was developed such that the resolution and speed of the camera for data acquisition could be modified according to the irradiation angle of the laser. Furthermore, it was developed considering the mountability of the entire system to prevent interference with the sealer ejection machine. In addition, a vision signal processing module was developed using the Zynq-7020 FPGA chip to improve the processing speed of the algorithm that converted the profile to the sealer shape image acquired from a 2D camera and calculated the width and height of the sealer using the converted profile. The performance of the developed sealer application inspection system was verified by establishing an experimental environment identical to that of an actual automobile production line. The experimental results confirmed the performance of the sealer application inspection at a level that satisfied the requirements of automotive field standards.

THE EFFECT OF CANAL FILLING SEALER TO RESIN CEMENT IN POST CEMENTATION (근관충전용 sealer의 성분이 포스트 세멘트시 레진 세멘트에 미치는 영향)

  • Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • The purpose of this study was to evaluate the effect of the canal filling sealer to resin cement When posts were cemented in the endodontically treated teeth, 86 incisors were used. The coronal portion of the teeth were removed at the cemento-enamel junction, every tooth was done treatment of canal. And the teeth was divided was into 12 groups. G : I a n : 7 Treatment : Z.P.C (1 day after Z.O.E. sealer) G : I b n : 7 Treatment : All-Bond (3 day after sealer) G : II a n : 8 Treatemt : Z.P.C (3 day after sealer) G : II b n : 7 Treatemt : All-Bond (3 day after sealer) G : III a n : 8 Treatemt : Z.P.C (7 day after sealer) G : III b n : 8 Treatemt : All-Bond (7 day after sealer) G : IV a n : 7 Treatemt : Z.P.C (1 day after Apexit sealer) G : IV b n : 7 Treatemt : All-Bond (1 day after sealer) G : V a n : 7 Treatemt : Z.P.C (3 day after sealer) G : V b n : 7 Treatemt : All-Bond (3 day after sealer) G : VI a n : 7 Treatemt : Z.P.C (7 day after sealer) G : VI a n : 7 Treatemt : All-Bond (7 day after sealer) Ready made stainless steel Para-post(PD-K-3) was cemented with Z.P.C. in subgroup a, and cemented with All-Bond & composite resin cement in subgroup b to depth 7mm. After 5 days at cementation of post, teeth with cemented posts were mounted on a retention jig and the failure loads of the specimens were measured by an Instron Universal Testing Machine. The results were as follows. 1. The results of failure loads were $15.5{\pm}7.1kg$ in group I b, $21.6{\pm}5.4kg$ in group II b and $20.1{\pm}18.1kg$ in group III b, and there was no statistically significant , difference between each group(p>0.05). 2. The results of failure loads were $19.0{\pm}6.7kg$ in group IV b, $17.3{\pm}6.5kg$ in group V b.and $18.9{\pm}7.9kg$ in group VI b and there was no significant difference between each other(p>0.05). 3. In same condition, the failure load of subgroup a was largely higher the subgroup b. But there was no significant difference between each other(p>0.05).

  • PDF

THE CANAL SEALING EFFECT OF WARM LATERAL CONDENSATION OF GUTTA-PERCHA (가온 측방가압 근관충전법의 폐쇄효과)

  • Kim, Yong-Duk;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.429-446
    • /
    • 1994
  • The purpose of this study was to evaluate the sealing effect of warm lateral condensation technique by Endotec spreader, comparing with other canal filling techniques. One hundred and forty extracted human teeth with single canal were instrumented and randomly divided into four groups according to canal filling techniques including lateral condensation with sealer, warm lateral condensation with sealer, warm lateral condensation without sealer, and injection-molded thermoplasticized gutta-percha without sealer. Obturated canals were exposed to 2 % methylene blue solution at $37^{\circ}C$ for 24 hours and measurement of the degree of microleakage was done linearly and volumetrically with stereozoom microscope and UV-spectrophotometer respectively. The results were as follows ; When sealer was used, the canals obturated by warm lateral condensation showed less leakage linearly and volumetrically than the canals obturated by standard lateral condensation with no statistically significant difference. The obturated canals by warm lateral condensation with sealer showed less leakage linearly and volumetrically than the canals obturated by warm lateral condensation without sealer and by injection-molded thermoplasticized gutta-percha without sealer with statistical significance (p<0.05). No statistical difference revealed that the group filled with the use of the Endotec had significantly less leakage than any of the other groups. There was a significant correlation between the linear measurement and volumetric measurement(r=0.4459, p<0.05).

  • PDF