• Title/Summary/Keyword: sd-system

Search Result 1,031, Processing Time 0.04 seconds

A Design of AES-based WiBro Security Processor (AES 기반 와이브로 보안 프로세서 설계)

  • Kim, Jong-Hwan;Shin, Kyung-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.71-80
    • /
    • 2007
  • This paper describes an efficient hardware design of WiBro security processor (WBSec) supporting for the security sub-layer of WiBro wireless internet system. The WBSec processor, which is based on AES (Advanced Encryption Standard) block cipher algorithm, performs data oncryption/decryption, authentication/integrity, and key encryption/decryption for packet data protection of wireless network. It carries out the modes of ECB, CTR, CBC, CCM and key wrap/unwrap with two AES cores working in parallel. In order to achieve an area-efficient implementation, two design techniques are considered; First, round transformation block within AES core is designed using a shared structure for encryption/decryption. Secondly, SubByte/InvSubByte blocks that require the largest hardware in AES core are implemented using field transformation technique. It results that the gate count of WBSec is reduced by about 25% compared with conventional LUT (Look-Up Table)-based design. The WBSec processor designed in Verilog-HDL has about 22,350 gates, and the estimated throughput is about 16-Mbps at key wrap mode and maximum 213-Mbps at CCM mode, thus it can be used for hardware design of WiBro security system.

Reconfigurable SoC Design with Hierarchical FSM and Synchronous Dataflow Model (Hierarchical FSM과 Synchronous Dataflow Model을 이용한 재구성 가능한 SoC의 설계)

  • 이성현;유승주;최기영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.8
    • /
    • pp.619-630
    • /
    • 2003
  • We present a method of runtime configuration scheduling in reconfigurable SoC design. As a model of computation, we use a popular formal model of computation, hierarchical FSM (HFSM) with synchronous dataflow (SDF) model, in short, HFSM-SDF model. In reconfigurable SoC design with HFSM-SDF model, the problem of configuration scheduling becomes challenging due to the dynamic behavior of the system such as concurrent execution of state transitions (by AND relation), complex control flow (HFSM), and complex schedules of SDF actor firing. This makes it hard to hide configuration latency efficiently with compile-time static configuration scheduling. To resolve the problem, it is necessary to know the exact order of required configurations during runtime and to perform runtime configuration scheduling. To obtain the exact order of configurations, we exploit the inherent property of HFSM-SDF that the execution order of SDF actors can be determined before executing the state transition of top FSM. After obtaining the order information and storing it in the ready configuration queue (ready CQ), we execute the state transition. During the execution, whenever there is FPGA resource available, a new configuration is selected from the ready CQ and fetched by the runtime configuration scheduler. We applied the method to an MPEG4 decoder and IS95 design and obtained up to 21.8% improvement in system runtime with a negligible overhead of memory usage.

Selection of Auditory Icons in Ship Bridge Alarm Management System Using the Sensibility Evaluation (감성평가를 이용한 선교알람관리시스템의 청각아이콘 평가)

  • Oh, Seungbin;Jang, Jun-Hyuk;Park, Jin Hyoung;Kim, Hongtae
    • Journal of Navigation and Port Research
    • /
    • v.37 no.4
    • /
    • pp.401-407
    • /
    • 2013
  • In parallel with the development of ship equipment, bridge systems have been improved, but marine accidents due to human error have not been reduced. Recently, research in nautical bridge equipment has focused on suitable ergonomic designs in order to reduce these errors due to human factors. In a bridge of a ship, there are numerous auditory signals that deliver important information clearly to the sailors. However, only a few studies have been conducted related to the human recognition of these auditory signals. There are three types of auditory signals: voice alarms, abstract sounds, and auditory icons. This study was conducted in order to design more appropriate auditory icons using a sensibility evaluation method. The auditory icons were rated to have five warning situations (engine failure, fire, steering failure, low power, and collision) using the Semantic Differential Method. It is expected that the results of this study will be used as basic data for auditory displays inside bridges and for integrated bridge alarm systems.

Effect of Herbal-Acupuncture on Repeated Cocaine-induced Behavioral Sensitization in the Rat (약침이 반복적인 코카인 투여로 인한 행동적 민감화 현상에 미치는 효과)

  • Lee, B.B;Yang, C.H.;Hahm, D.H.;Lee, H.J.;Shim, I.S.
    • Journal of Pharmacopuncture
    • /
    • v.7 no.1 s.12
    • /
    • pp.53-61
    • /
    • 2004
  • Substantial evidence suggests that behavioral and reinforcing effects of cocaine can be mediated by the mesolimbic dopaminergic system. It has been shown that repeated injections of cocaine produce increase in locomotor activity, expression of the immediate-early gene, c-fos in the nucleus accumbens (NAc), which was one of the main dopaminergic terminal areas. Herbal-acupuncture as a therapeutic intervention has been widely used for the treatment of many functional disorders such as drug abuse. Coptidis Rhizoma (CR) and its main component, berberine (BER) were selected as herbal medicine of herbal-acupuncture. Both medicines have been known to have the therapeutic effect on the central nervous system. In order to investigate the effects of CR and BER herbalacupuncture at shenmen (HT7) point (CR/H and BER/H) on the cocaine-induced behavioral sensitization, the influence of CR/H and BER/H on repeated cocaine-induced locomotor activity, the change of c-Fos expression in the brain by immunohistochemistry were examined. Male SD rats were given CR/H (0.4mg/kg) and BER/H (0.1mg/kg) 30 min before daily injections of cocaine hydrochloride (15mg/kg. i.p.) 10 days. After 3 days withdrawal, rats received a challenge injection of cocaine (15mg/kg, i.p.). Systemic challenge with cocaine produced much larger increased locomotor activity, accumbal Fos-like immunoreactivity in the NAc. Pretreatment with CR/H and BER/H significantly inhibited cocaine-induced locomotor activity, the change of c-Fos expression in the rats. Our data demonstrated that the inhibitory effects of cocaine-induced behavioral sensitization by CR/H and BER/H were closely associated with the reduction of presynaptic dopamine release in the NAc. These results suggest that CR/H and BER/H can be effectively applied to cocaine addiction.

Predictive Factors for Medication Adherence in a Geriatric Assessment Program in Korea (노인환자의 복약순응도 현황 및 영향인자 분석)

  • Kim, Minso;Choi, Nayae;Suh, Yewon;Park, Jinyoung;Lee, Junghwa;Lee, Eunsook;Lee, Euni;Kim, Sun-wook;Kim, Kwang-Il;Kim, Cheol-Ho
    • Journal of Korean Society of Health-System Pharmacists
    • /
    • v.35 no.4
    • /
    • pp.418-429
    • /
    • 2018
  • Background : To improve medication adherence in elderly patients, the role of pharmacists in teambased services has been highlighted in the literature. However, not much is known about the role and the service elements involved in comprehensive geriatric programs in South Korea. This study was designed to describe the current status of medication adherence in geriatric patients based on the comprehensive geriatric assessment program and analyze the predictive factors for medication adherence in a tertiary teaching hospital. Methods : A retrospective cohort study was performed using electronic medical records of 247 patients from March 1st, 2015 to August 31st, 2015. Medication adherence and the types of non-adherence were also collected. Predictive factors for adherence were evaluated by including factors related to demographics, medications, illness, and patterns of medical usage. Results : The mean age of the study population was 81.2 years (range 65~98 years) and they were taking 9.7 drugs on an average (SD 5.0 drugs). The overall rate of non-adherence was 34%. About 48% of the patients had any forms of assistance in the medication administration. The most common type of non-adherence was "self-adjustment". The multivariate analyses revealed that age (adjusted odds ratio, 0.87 [95% CI, 0.80-0.96]; p 0.05) and the number of inappropriate medications (adjusted odds ratio, 0.59 [95% CI, 0.40-0.89]; p 0.05) were strong predictors for non-adherence. Conclusions : These results indicate that strategic considerations of the predictors of non-adherence should be improved in medication counseling services targeting elderly patients.

Safety effect of fermented oyster extract on the endocrine disruptor assay in vitro and in vivo

  • Lee, Hyesook;Hwangbo, Hyun;Ji, Seon Yeong;Oh, Seyeon;Byun, Kyung-A;Park, Joung-Hyun;Lee, Bae-Jin;Kim, Gi-Young;Choi, Yung Hyun
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.10
    • /
    • pp.330-339
    • /
    • 2021
  • Oyster (Crassostrea gigas) is a marine bivalve mollusk widely distributed in coastal areas, and have been long widely used in industrial resources. Several studies demonstrated that fermented oyster (FO) extract attribute to bone health, but whether administration of FO play as an endocrine disruptor has not been studied. Therefore, in the present study, we investigated the effect of FO on the endocrine system in vitro and in vivo. As the results of the competitive estrogen receptor (ER) and androgen receptor (AR) binding affinities, FO was not combined with ER-α, ER-β, and AR. However, 17β-estradiol and testosterone, used as positive control, were interacted with ER and AR, respectively. Meanwhile, oral administration of 100 mg/kg and 200 mg/kg of FO doesn't have any harmful effect on the body weight, androgen-dependent sex accessory organs, estrogen-dependent-sex accessory organs, kidney, and liver in immature rats. In addition, FO supplementation has no effect on the serum levels of luteinizing hormone (LH), follicle stimulating hormone (FSH), testosterone, and 17β-estradiol. However, the relative weight of androgen- and estrogen-dependent organs were significantly increased by subcutaneously injection of 4.0 mg/kg of testosterone propionate (TP) and by orally administration of 1.0 ㎍ of 17α-ethynyl estradiol (EE) in immature male and female rats, respectively. Furthermore, TP and EE administration markedly decreased the serum LH and FSH levels, which are similar those of mature Sprague-Dawley (SD) rat. Furthermore, the testosterone and 17β-estradiol levels were significantly enhanced in TP and EE-treated immature rats. Taken together, our findings showed that FO does not interact with ER and AR, suggesting consequentially FO does not play as a ligand for ER and AR. Furthermore, oral administration of FO did not act as an endocrine disruptor including androgenic activity, estrogenic activity, and abnormal levels of sex hormone, indicating FO may ensure the safety on endocrine system to develop dietary supplement for bone health.

A Fully Digital Automatic Gain Control System with Wide Dynamic Range Power Detectors for DVB-S2 Application (넓은 동적 영역의 파워 검출기를 이용한 DVB-S2용 디지털 자동 이득 제어 시스템)

  • Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.58-67
    • /
    • 2009
  • This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25 dB to the desired level within $10{\mu}s$. It is implemented in a $0.18{\mu}m$ CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8 nV/$\sqrt{Hz}$ input referred noise, and 5-dBm $IIP_3$ at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100 MHz input.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Study on the Effect of Contact Angles of Elastic Rubber Impression Materials on the Surface of Working Cast (탄성 고무인상재의 접촉각이 작업모형 표면에 미치는 영향)

  • Kim, Joo-Won
    • Journal of dental hygiene science
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • This study was begun to search effect of contact angles of elastic rubber impression materials on the surface of working cast. Of elastic rubber impression materials with a Type III consistency, such as polysulfide, polyether and addition silicone, we selected one and then measured the contact angle after dripping a distilled water 3.3ml. Then, after pouring a dental anhydrite in three types of impression materials, we prepared a working cast and then examined its surface. Contact angle was measured using a full automatic contact angle measuring system (DM-700, KYOWA, Japan), and the surface of working cast was observed using a field emission scanning electron microscope (JSM-6700F, JEOL Ltd., JAPAN). The following results were obtained: 1) $Mean{\pm}SD$ (SD: standard deviation) of the initial contact angles were $91.3{\pm}20.5^{\circ}$ in the addition silicone materials, $90.0{\pm}2.2^{\circ}$ in the polyethers and $101.5{\pm}2.3^{\circ}$ in the polysulfides. These results indicate that mean values were similar but standard deviations of the three materials showed a great discrepancy. 2) As the time elapsed, addition silicone materials were found to have a contact angle decreased abruptly as compared with the remaining two types. That is, the initial contact angle was $91.3^{\circ}$ and it was abruptly decreased to $29.4^{\circ}$ after 25 seconds. 3) In the polyethers, the initial contact angle was $101.5^{\circ}$ and it was decreased to $90.7^{\circ}$ after 25 seconds. In the polysulfides, however, the initial contact angle was $90.0^{\circ}$ and it was $84.2^{\circ}$ after 25 seconds. This showed almost no changes in the initial contact angles. Moreover, its magnitude was greater than that seen in additional silicones. 4) There were significant differences in the contact angles between the three types of elastic rubber impression materials as the time elapsed (p<0.001). On an observation on the surface of working cast, addition silicone materials were found to have the most dense surface. This was followed by polysulfides and polyethers in a descending order.

Effects of Insoluble Dietary Fiber Supplementation on Performance and Nutrient Digestibility of Weanling Pigs (난용성 식이섬유의 첨가가 이유자돈의 생산성 및 영양소 소화율에 미치는 영향)

  • Han, Y.K.;Han, K.Y.;Lee, J.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.565-572
    • /
    • 2005
  • An experiment was conducted to determine the effect of supplementation of insoluble dietary fiber (Vitacel®) on growth performance and nutrient digestibility in weanling pigs. A total of 96 pigs that averaged 6.49$\pm$0.52kg BW and 23$\pm$2.1d age were allocated in a randomized block design with two pigs per pen and 12 pens per treatment. Pigs and feeders were weighed 10-days interval for the 40-d trials to determine ADG, ADFI and feed:gain ratio(F:G). Pigs were fed one of four diets:1) Control diet (C) 2) C+0.3% insoluble dietary fiber(IDF) 3) C+0.6% IDF and 4) c+0.9% IDF. For the determination of fecal nutrients digestibility, pigs were fed diets(diet 2) with 1% Celite-545(Fluka) as a marker and feces were collected on $9^{th}$ day and $18^{th}$ day after feeding diet 2. During the whole experimental period, pigs fed diet with 0.3% IDF have significantly higher ADG than other dietary treatment groups(P<0.05). ADG of pigs fed diet with 0.6% IDF was higher than that of pigs fed control diet(P<0.05). However, there was no significant difference in ADG between control group and 0.9% IDF group(P>0.05). ADFI of pigs fed diet with 0.3% IDF was significantly higher than any other dietary treatment groups(P<0.05). There was no significant difference in ADFI among control group, 0.6% and 0.9% IDF supplementation groups (P>0.05). Digestibilities of organic matter, crude protein, crude fiber and energy were significantly higher in 0.3% IDF supplementation group than any other dietary groups. However, there was no difference in over all nutrient digestibilities between 0.6% and 0.9% IDF group. Feeding diets more than 0.6% IDF did not affect the rest of the nutrients digestibilities except for ADF digestibility compared to control diet. Dietary supplementation level of IDF showed a significant quadratic effect on performance improvement of piglets. This response of growth performance to IDF supplementation is, as expected, in agreement with that of nutrient digestibility. Our results showed that IDF supplementation to diet for weaned piglets might be beneficial in terms of growth and nutrient digestibility. However, there should be more study on the relationship between level of IDF supplementation and piglet response as well as the exact mode of action of IDF in weaned piglets.