• Title/Summary/Keyword: sd-system

Search Result 1,031, Processing Time 0.034 seconds

The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge (표면방전의 집중에 따른 옥외용 설비의 성능평가)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin;No, Jin-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

A New Environmental Technology Certification System(NETCS) System Dynamics Modeling for the Operational Improvement of Companies Possessing New Environmental Technology (환경신기술 보유 기업의 운영개선을 위한 환경신기술 인증제도 시스템다이내믹스 모델링)

  • Kim, Tae Young;Park, Su Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.399-399
    • /
    • 2020
  • 본 연구에서는 시스템다이내믹스(System Dynamics, SD) 방법론에 입각하여 국내의 신기술인증제도(New Technology Certification System, NTCS)의 운영에 내재된 요소들 간의 상호관계를 신기술 개발투자, 신기술의 사업화 및 신기술에 의한 매출과 연관하여 피드백루프 메카니즘을 내포하고 있는 인과지도로 규명하였다. 이렇게 개념화된 인과지도는 국내의 여러 신기술인증제도 중 환경부에서 운영중인 '환경신기술인증 및 기술검증제도(New Excellent Technology and Environmental Technology Verification, NET & ETV)'에 적용되었으며 NET & ETV의 운영 성과를 신기술에 의한 매출액(수주금액)의 관점에서 분석 및 예측할 수 있는 SD 컴퓨터 시뮬레이션 모델이 개발되었다. 개발된 SD 모형은 NET & ETV 운영의 주요 지표에 관한 기존 통계자료를 적절히 모사하였으며 모형의 검증과정에서 시행착오를 통하여 산정된 값들은 NET & ETV의 일반적인 과거 상태를 합리적인 범위 내에서 적절하게 나타내고 있는 것으로 나타났다. 본 연구에서는 개발된 SD모형을 이용하여 기본시나리오에 대한 NET & ETV의 미래 운영 상태를 예측하였으며, 환경신기술의 적용 현장 당 수주금액에 대한 시간 추세선식의 민감도를 발견하였다.

  • PDF

Fractionated Stereotactic Radiotherapy (FSRT) Using Gold Markers : A Comparison of the Isocenter between Multiple Arcs and Static Conformal Beams (금속표지자를 이용한 다중호형 정위방사선치료와 입체조형 정위방사선치료의 회전중심점 비교)

  • 장지영;김기환;김재성;김준상;송창준;김선환;조문준
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • The aim of the study was to assess the isocenter deviation between multiple arcs and conformal beams in frameless FSRT. Forty seven patients received single isocenter radiosurgery or therapy (SRS/T) using available framelss FSRT system from Aug. 1997 to Dec. 2m. In choosing multiple arc FSRT or conformal FSRT, we had considered one of two techniques with respect to tumor size and tumor shape. In multiple arc FSRT, the average and standard deviation (SD) of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.2 mm (SD 0.2) and 0.3 mm (SD 0.2 mm)in the lateral (x), anterior-posterior (y) and cranio-caudal directions (z). In conformal FSRT, the average deviation and SD of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.3 mm(0.2 mm) and 0.4 mm (SD 0.2 mm) in the x, y and z directions. The average spacial deviation ($\Delta$r) was 0.41 mm and 0.54 mm in multiple arcs and conformal beams, respectively. The isocenter deviation using frameless FSRT system was similar value between multiple arcs and conformal beams. In practice, we believed we can select the appropriate treatment technique according to tumor shape and size.

  • PDF

Initial Size Distribution of the Milky Way Globular Clusters

  • Shin, Ji-Hye;Kim, Sung-Soo S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.35.1-35.1
    • /
    • 2010
  • Unlike the initial mass function, the initial size distribution of globular cluster (GC) systems is not well known. We calculate the evolution of the mass function (MF), radial distribution (RD), and size distribution (SD) of the Galactic GC system. By comparing the results from this calculation and the present-day MF, RD, and SD of the Galactic GC system, we infer the initial SD of the GC system. We find that a Gaussian distribution of the half-mass radius and a Gaussian distribution of the half-mass to Jacobi radius ratio are the best-fit initial SDs of the Galactic GC system.

  • PDF

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Survey of drug resistance in Edwardsiella tarda isolated from diseased eels(Anguilla japonica) (뱀장어 병어로부터 분리한 Edwardsiella tarda의 약제내성)

  • Choi, Min-Soon;Choi, Sang-Hoon;Park, Kwan-Ha;Jang, Seon-Il;Yoon, Chang-Yong;Cho, Jeong-Gon;Song, Hee-Jong
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.195-201
    • /
    • 1996
  • Ninety-six isolates of Edwardsiella tarda recovered from outbreaks of Edwardsiellosis in cultured eels(Anguilla japonica) in Kunsan, were examined for drug susceptibility, distribution and transferabilities of R plasmid. All of the E. tarda isolates examined were sensitive to gentamicin(GM), streptomycin(SM), norfloxacin(NF), and amikacin(AK). But most isolates were resistant to sulfadimethoxine(SD, 86 strains), ampicillin(AM, 84 strains), penicillin G(PM, 80 strains), nalidixic acid (NA, 67 strains), oxytetracycline(OT, 44 strains), and oxolinic acid(OA, 37 strains). Twenty different combinations of drug resistance patterns were observed : the frequently encountered pattern was SD-AM-PM-NA-OA(16 strains), SD-AM-PM-NA(14 strains), SD-AM-PM-NA-OT-OA(12 strains), SD-AM-PM-OT(10 strains), and SD-AM-PM-NA-OT(8 strains). Transferable R plasmids were found out to be carried in 78 out of 94 resistant strains, indicating that these isolates carry conjugally transferable R plasmids associated with single or multiple drugs. The frequently observed transferarble R plasmids were AM(8 strains), AM-PM-NA(8 strains), Am-SD(6 strains), PM(6 strains), and SD(6 strains) These results suggest that high dose of various antibacterials might have already been introduced to eel culture system leading to the acquirement of multi-drug resistance to wide range of antibacterials.

  • PDF

Development of HPCI Prediction Model for Concrete Pavement Using Expressway PMS Database (고속도로 PMS D/B를 활용한 콘크리트 포장 상태지수(HPCI) 예측모델 개발 연구)

  • Suh, Young-Chan;Kwon, Sang-Hyun;Jung, Dong-Hyuk;Jeong, Jin-Hoon;Kang, Min-Soo
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.83-95
    • /
    • 2017
  • PURPOSES : The purpose of this study is to develop a regression model to predict the International Roughness Index(IRI) and Surface Distress(SD) for the estimation of HPCI using Expressway Pavement Management System(PMS). METHODS : To develop an HPCI prediction model, prediction models of IRI and SD were developed in advance. The independent variables considered in the models were pavement age, Annual Average Daily Traffic Volume(AADT), the amount of deicing salt used, the severity of Alkali Silica Reaction(ASR), average temperature, annual temperature difference, number of days of precipitation, number of days of snowfall, number of days below zero temperature, and so on. RESULTS : The present IRI, age, AADT, annual temperature differential, number of days of precipitation and ASR severity were chosen as independent variables for the IRI prediction model. In addition, the present IRI, present SD, amount of deicing chemical used, and annual temperature differential were chosen as independent variables for the SD prediction model. CONCLUSIONS : The models for predicting IRI and SD were developed. The predicted HPCI can be calculated from the HPCI equation using the predicted IRI and SD.

Research on Applicability of Laser Ablation Propulsion to Space Debris Removal by Simulations (시뮬레이션을 통한 레이저 융삭 추진의 우주 쓰레기 제거 응용 가능성 연구)

  • Yoo, Seong-Moon;Lee, Seung-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.169-176
    • /
    • 2022
  • Laser ablation propulsion(LAP) is the method to create impulse by laser ablation. It can be used to deorbit the space debris(SD), as its long-range property and versatility on any material. In this paper, we find out several requirements of the LAP system(LAPS) to deorbit the SD by simple numerical calculations of the SD orbit and laser beam flux. As a result, minimum operable altitude angle turned out to be a crucial variable to the LAPS. Moreover, if minimum operable altitude angle is 10°, and if the minimum distance between the LAPS and the SD is below 450 km, 1 m/s2 is sufficient to deorbit the SD by once. With 18 kJ/3 ns pulsed laser and cube shaped 100 kg SD, 1 m/s2 acceleration can be achieved by increasing the pulse repetition rate over 34~53 Hz, depending on the size of the SD. This capability could compare with the conceptual design of the Japan Establishment for a Power-laser Community Harvest(J-EPoCH) facility, which include 8 kJ, 5 PW@100 Hz laser.

A SD approach to the Efficiency Improvement of Electric Power Industry in Korea: Focused on the Nuclear Industry (시스템 다이내믹스(SD)에 의한 국내 전력산업의 효율성 제고에 관한 연구: 원자력산업을 중심으로)

  • Lee, Myoung-Ho;Lee, Hee-Sang;Jang, In-Sung;Choi, Bong-Sik;Huh, Hoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.2
    • /
    • pp.99-109
    • /
    • 2001
  • In this study, we tried to build a model which can deal with the efficient and effective operation of electric power industry, especially focused on the nuclear industry. Here, SD (System Dynamics) approach is used to visualize the underlying phenomenon of the nuclear power industry. SD is a methodology for studying and managing complex feedback systems, such as one finds in business and other social systems. The spend of SD applications has grown extensively and now encompasses work in corporate planning and policy design, public management and policy, biological and medical modeling, energy and the environment. Recently, according to the report from KEPCO (Korea Electric Power Corporation), they are considering delaying a new power plant construction. It may be based upon business fluctuation downsized from Korean economic crisis in 1997 and freezing of construction funds due to unstable foreign exchange rate. At this point, we need disparately a kind of strategic model that would contribute to cope with the current business situation, energy generation, production, and resulting pollution. Specifically, this model, using SD approach, starts with the detailed drawing of influence diagram, which describes those relevant key points on nuclear power generation systems in electric power industry of Korea. These include such factors as the operation of nuclear industry and parameters related to the decision making for business policy. Based upon the above-mentioned influence diagram drawn, we developed SD simulation model to evaluate and analyze strategic management of KEPCO. Based on our analysis, we could demonstrate how simulation model can be applied to the real electric power generation in Korea.

  • PDF

High Speed SD-OCT System Using GPU Accelerated Mode for in vivo Human Eye Imaging

  • Cho, Nam Hyun;Jung, Unsang;Kim, Suhwan;Jung, Woonggyu;Oh, Junghwan;Kang, Hyun Wook;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • We developed an SD-OCT (Spectral Domain-Optical Coherence Tomography) system which uses a GPU (Graphics Processing Unit) for processing. The image size from the SD-OCT system is $1024{\times}512$ and the speed is 110 frame/sec in real-time. K-domain linearization, FFT (Fast Fourier Transform), and log scaling were included in the GPU processing. The signal processing speed was about 62 ms using a CPU (Central Processing Unit) and 1.6 ms using a GPU, which is 39 times faster. We performed an in-vivo retinal scan, and reconstructed a 3D visualization based on C-scan images. As a result, there were minimal motion artifacts and we confirmed that tomograms of blood vessels, the optic nerve, and the optic disk are clearly identified. According to the results of this study, this SD-OCT can be applied to real-time 3D display technology, particularly auxiliary instruments for eye operations in ophthalmology.