• Title/Summary/Keyword: scrubbing

Search Result 149, Processing Time 0.022 seconds

Optimization of Electrolytic Oxidant OCl- Production for Malodorous VOCs Removal (악취성 VOCs 제거를 위한 전해 산화제 OCl-의 생산 최적화)

  • Yang, Woo Young;Lee, Tae Ho;Ryu, Hee Wook
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.152-159
    • /
    • 2021
  • Volatile organic compounds (VOCs) occur in indoor and outdoor industrial and urban areas and cause environmental problems. Malodorous VOCs, along with aesthetic discomfort, can have a serious effect on the human body. Compared with the existing method of reducing malodorous VOCs, a wet scrubbing method using an electrolytic oxidant has the advantage of reducing pollutants and regenerating oxidants. This study investigated the optimal conditions for producing OCl-, a chlorine-oxidant. Experiments were conducted by changing the type of anode and cathode electrode, the type of electrolyte, the concentration of electrolytes, and the current density. With Ti/IrO2 as the anode electrode and Ti as the cathode electrode, OClproduction was highest and most stable. Although OCl- production was similar with the use of KCl or NaCl, NaCl is preferable because it is cheap and easy to obtain. The effect of NaCl concentration and current density was examined, and the OCl- production rate and concentration were highest at 0.75 M NaCl and 0.03 A cm-2. However, considering the cost of electric power, OCl- production under the conditions of 1.00 M NaCl and 0.01 A cm-2 was most effective among the conditions examined. It is desirable to produce OCl- by adjusting the current density in accordance with the concentration and characteristics of pollutants.

Development of Mobile Vortex Wet Scrubber and Evaluation of Gas Removal Efficiency (기체상 유해화학물질 제거를 위한 이동형 와류식 세정장치 개발 및 가스 제거효율 분석)

  • Kwak, Ji Hyun;Hwang, Seung-Ryul;Lee, Yeon-Hee;Kim, Jae-Young;Song, Ki Bong;Kim, Kyun;Kang, Jae Eun;Lee, Sang Jae;Jeon, Junho;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.2
    • /
    • pp.134-138
    • /
    • 2015
  • BACKGROUND: In recent years, several researchers have focused on odour control methods to remove the harmful chemicals from chemical accidents and incidents. The present work deals with the system development of the hazardous. METHODS AND RESULTS: For on-site removal of hazardous gaseous materials from chemical accidents, mobile vortex wet scrubber was designed with water vortex process to absorb the gas into the water. The efficiency of the mobile vortex wet scrubber was evaluated using water spray and 25% ammonia solution. The inlet air velocity (gas flow rate) was according to the damper angle installed within the hood and with increase of gas flow rate, consequently the absorption efficiency was markedly decreased. In particular, when 25% ammonia solution was exposed to the hood inlet for 30 min, the water pH within the scrubber was changed from 7 to 12. Interestingly, although the removal efficiency of ammonia gas exhibited approximately 80% for 5 min, its efficiency in 10 min showed the greatest decrease with 18%. Therefore, our results suggest that the ammonia gas may be absorbed with the driving force of scrubbing water in water vortex process of this scrubber. CONCLUSION: When chemical accidents are occurred, the designed compact scrubber may be utilized as effective tool regarding removal of ammonia gas and other volatile organic compounds in the scene of an accident.

A Study on the Surgical Hand Scrub and Surgical Glove Perforation (외과적 손씻기 및 외과용 장갑의 천공율에 대한 연구)

  • 윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.653-667
    • /
    • 1995
  • Post - operative wound infections have been a serious problem in nursing care in the operating room and appear to be strongly related to the infection occurring during the performance of operation. The purpose of this study is to identify patterns in duration of surgical hand scrub (SHS), to evaluate the method of SHS and to examine the rate of glove perforation. Subjects for this study include 244 doctors and 169 nurses working in the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between April 1, through 15, and July 1, through 5, 1995 by the author and a staff member working in the operating room. For the study, data on the SHS of doctors and nurses were obtained at the time of operation and multiple batches of surgical gloves worn by the operating doctors were collected after each operation. The duration of SHS was measured with a stop watch and the method of SHS was evaluated according to Scoring Hand Scrub Criteria (SHS Criteria) and expressed as SHS scores. For the analysis of the data, t-test was used to compare the differences in the duration and the SHS scores of doctors and nurses, and Pearson's correlation coefficient was used to examine the relationship between the SHS duration and the SHS scores. The results of the study are summarized as follows. 1) The mean time spent in each SHS was 167 seconds in nurses, and 127 seconds in doctors. The data comparing nurses and doctors indicated that there were significant differences in Our ation of SH S between these two groups (t=5.58, p=.000). 2) The mean time spent in the first SHS was 145 seconds and that in the End SHS, 135 seconds, and there was not a significant difference in the duration of the SHS between doctors and nurses (t=1.44, P=.156). 3) The mean time spent in the SHS by OS (Orthopaedic surgery) doctors was 162 seconds, 150 seconds by NS(Neurologic surgery), 121 seconds by GS(General surgery), 94 seconds by OPH(Opthalmology) and DS(Dental surgery), 82 seconds by URO(Urology), 78 seconds by PS(Plastic surgery) and 40 seconds by ENT(Ear, Nose & Throat) These also showed a significant difference in the duration of the SHS among the medical specialities (t=4.8, P=.0001). 4) The average SHS score of the nurses was 15.2, while that of doctors was 13.1. The statistical analysis showed that t-value was 3.66, p was. 000. This indicates that the nurses actually clean their hands more thoroughly than the doctors do. 5) The average SHS score of NS doctors was 15.5, 15.3 for doctors for OPH,14.3 for OS,12.7 for GS, 12.0 for DS, 11.7 for URO, 10.1 for PS, 7.5 for ENT. Comparison of the average SHS scores from 8 specialties showed that there was a significant differences in the patterns of the SHS (F=5.08, P=.000) among medical specialties. 6) It appears that the operating personnel scrub the palms and dorsum of their hand relatively well, however, less thorough the nails and fingers. 7) The more the operating personnel spend their time in hand scrubbing, the more correctly they clean their hands(r=.6427, P<.001). 8) The overall frequencies of perforation in all post-operative gloves tested was 38 out of 389 gloves (10.3%). The perforation rate for PS was 13%, 12.1% for GS,8.8% for 05, and 3.3% for NS.

  • PDF

The Influence of Thermal Condition on the Variation of Reaction Product Composition depending on the Constituent of Dolomite in the Absorption Process of SO2 by Dolomite (Dolomite에 의한 SO2 흡수공정에서 Dolomite 조성에 따른 생성물질 구성 변화에 대한 열적 조건 영향)

  • You, Dong-Ju;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.23 no.2
    • /
    • pp.17-25
    • /
    • 2014
  • The thermal effect on the compositional change of the $SO_2$ absorption process product was investigated compared with the composition of raw material when dolomite is employed in place of lime in the scrubbing process based on thermodynamic estimation. It was considered that the equilibrium reactions which directly related with the formation of $CaSO_4$ and $MgSO_4$, the absorption process products, are those between $Ca^{2+}$ and $Ca(OH)_2$, $Mg^{2+}$ and $Mg(OH)_2$, and the secondary dissociation reaction of $H_2SO_4$. It was thought to be necessary to examine the enthalpy change for the formation reactions of $CaSO_4$ and $MgSO_4$ along with the thermal feature of the relative reactions to figure out the influence of temperature on the compositional change of absorption process products. The stable regions for $Ca(OH)_2$ and $Mg(OH)_2$ in Pourbaix diagram were found to be increased as temperature rises and the equilibrium reaction between $Ca^{2+}$ and $Ca(OH)_2$ was investigated to be more strongly influence by temperature change compared with the equilibrium reaction between $Mg^{2+}$ and $Mg(OH)_2$. The amounts of $CaSO_4$ and $MgSO_4$ were anticipated to be decreased with temperature considering the thermal characteristics for the equilibrium reactions regarding calcium, magnesium, and $H_2SO_4$. It was understood that the formation ratio between $CaSO_4$ and $MgSO_4$ is greater than the composition ratio between calcium and magnesium contained in dolomite at specific temperature and the decrease of the formation ratio of $CaSO_4$ and $MgSO_4$ with temperature was estimated to be diminished as the content of calcium in dolomite is increased. In addition, the extent of the change in the compositional ratio between absorption process products was examined to be reduced compared with the composition of raw material as the calcium content in dolomite is raised.

The Effects of Additional Tetracycline Pleurodesis during Thoracoscopic Procedures for Treating Primary Spontaneous Pneumothorax (일차성 자연 기흉의 흉강경 수술 시 추가로 시행한 Textracycline 흉막 유착술의 효용)

  • Lee, Hyeon-Woong;Lee, Jae-Ik;Kim, Keun-Woo;Park, Kook-Yang;Park, Chul-Hyun;Hyun, Sung-Youl;Jeon, Yang-Bin;Choi, Chang-Hyu
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.729-735
    • /
    • 2008
  • Background: This study was performed to evaluate the safety and efficacy of performing additional tetracycline pleurodesis during the thoracoscopic treatment of primary spontaneous pneumothorax. Material and Method: Between March 2004 and December 2007, 91 cases of primary spontaneous pneumothorax were treated by video-assisted thoracoscopic surgery. The thoracoscopic procedures included resection of the blebs and mechanical pleurodesis by scrubbing the parietal pleura. For 27 cases (Tetracycline group, group I), 20 mg/kg tetracycline was instilled into the pleural space through a trocar before closing the chest. The control group (group II) consisted of 64 cases of primary spontaneous pneumothorax for which the same thoracoscopic procedures alone were performed during the same study period. Result: There was no significant difference between the two groups in terms of the demographic data, the operative findings and the operation time. The percentage of cases that needed intravenous analgesics and the duration of intravenous analgesics were comparable in both groups. There was no significant difference in the duration of air leaks and complications between the two groups. The patients treated with tetracycline pleurodesis had a longer period of postoperative chest drainage (4.2 days vs 3.5 days, respectively, p=0.03) and hospitalization (5.0 days vs 4.0 days, respectively, p=0.006). During the follow up period, the ipsilateral recurrence rate was much lower for the patients who were treated with tetracycline pleurodesis (0% vs 10.9%, respectively, p=0.099), and freedom from recurrence tended to be more favorable for group I (p=0.077), although this was not statistically significant. Conclusion: Additional tetracycline pleurodesis during thoracoscopic treatment for primary spontaneous pneumothorax caused prolongation of chest drainage and a prolonged hospital stay. However, further investigations are needed because tetracycline pleurodesis can be performed safely without serious complications and it showed a distinct tendency to reduce the rate of recurrence.

Characteristics of $CO_{2}$ Absorption and Degradation of Aqueous Alkanolamine Solutions in $CO_{2}$ and $CO_{2}-O_{2}$ System ($CO_{2}$$CO_{2}-O_{2}$ 시스템에서 알카놀아민류 흡수제를 이용한 $CO_{2}$ 흡수 및 흡수제 열화 특성)

  • Choi, Won-Joon;Lee, Jong-Seop;Han, Keun-Hee;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.256-262
    • /
    • 2011
  • Amine can undergo irreversible reactions by $O_{2}$ and high temperature in amine scrubbing process and these phenomena are called "degradation". Degradation causes not only a loss of valuable amine, but also operational problems such as foaming, corrosion and fouling. In this study, using various chemical absorbents(MEA; monoethanolamine, AMP; 2-amino-2-methyl-1-propanol, DAM; 1,8-diamino-p-menthane), we examined the following variable. I) loading ratio of $CO_{2}$ at $50^{\circ}C$ and $120^{\circ}C$, ii) concentration variation and initial degradation rate constant of absorbent in $CO_{2}$ and $CO_{2}/O_{2}$ system, and iii) effect of degradation by $O_{2}$. The $CO_{2}$ loading of 20 wt% DAM was 400% and 270% higher than that of 20 wt% MEA and AMP at 50, respectively and was the largest the difference of $CO_{2}$ loading between absorption $(50^{\circ}C)$ and regeneration $(120^{\circ}C)$ condition. The initial degradation rate constant of 20 wt% DAM was $2.254{\times}10^{-4}cycle^{-1}$ which was slower than that of MEA $(2.761{\times}10^{-4}cycle^{-1})$ and AMP $(2.461{\times}10^{-4}cycle^{-1})$ in $CO_{2}$ system. Also, it was increased 30% by $O_{2}$ that effects on the degradation by $O_{2}$ was less than 100% increased. these degradation reactions was able to identify by formation of new peak in GC and FT-IR spectrum analysis.

Development of Immediate Face Lifting Technology for Reducing Wrinkles by Using Film-Forming Agent (피막 형성제를 이용한 즉각 리프팅 기술 개발)

  • Jun, Ji hyun;Ko, Eun ah;Han, Sang Gun;Kang, Hakhee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.3
    • /
    • pp.211-218
    • /
    • 2018
  • Instant face lifting cosmetics contain various film forming agents for stretching the wrinkles on the skin surface. But, most of the film-forming polymers have sticky feels. And they are easily scrubbed out when skin is rubbed on. In this study, we focused on the influence of sodium silicate that has rapid film forming effect on skin surface and immediate wrinkle reducing effect. Sodium silicate, also known as water glass or soluble glass, is a compound containing sodium oxide and silica. Sodium silicate is a white powder that is readily soluble in water, producing an alkaline solution. Sodium silicate is stable in neutral and alkaline solutions. The sodium silicate solution hardens by drying in air and rapidly forms a thin film. When the solution is applied to the skin, the fine membrane coating is formed by water evaporation and ionic bond re-formation. It also makes the strong siloxane (Si-O) bonding on the skin surface. When these fixation properties are applied to cosmetics, they can give remarkable skin tightening effect. The sodium silicate solution can provide the lifting effect by forming a film on skin at a proper concentration. But, skin irritation may be caused with too high concentration of sodium silicate. We studied a desirable range of the sodium silicate concentration and combination with other fixatives for skin care formulation that has no sticky feels and no scrubbing out phenomenon. Immediate lifting gel was developed by using sodium silicate and various thickening systems. Among of the various thickeners, aluminum magnesium silicate showed the best compatibility with sodium silicate for rapid lifting effect. This instant physical lifting gel was confirmed as a low stimulating formula by skin clinical test.

A Respiration Rate Measurement of Fresh Fruits and Vegetables with a Corrected Pressure Variation Method (수정된 압력변위법을 이용한 과채류 호흡속도 측정)

  • Lee, Hyun-Dong;Chung, Hun-Sik;Kang, Jun-Soo;Chung, Shin-Kyo;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.1119-1124
    • /
    • 1997
  • This study was carried out for improvement and correction of the traditional pressure variation method (PVM) in the respiration rate measurements of fresh fruits and vegetables using a microcomputer system and a differential pressure sensor. Water vapor pressure in the container was calculated by equations for psychrometric calculations. At the beginning of experimental period water vapor pressure in the container was increased and maintained constantly in the most experimental period, but was decreased dramatically after $CO_2$ scrubbing. The percentages of water vapor pressure on total differential pressure were $33{\sim}46%$ at $1^{\circ}C$, $23{\sim}45%$ at $11^{circ}C$ and $35{\sim}53%$ at $21^{\circ}C$. The differences between the respiration rates determined by gas chromatography and corrected pressure variation method (CPVM) were $0.2{\sim}0.3\;mgCO_2kg^{-1}h^{-1}$ at $1^{\circ}C$, $0.2{\sim}2.9\;mgCO_2kg^{-1}h^{-1}$ at $11^{\circ}C$ and 1.0{\sim}9.0\;mgCO_2kg^{-1}h^{-1}$ at $21^{circ}C$, while those between gas chromatography and normal pressure variation method (PVM) were $0.8{\sim}1.2\;mgCO_2kg^{-1}h^{-1}$ at $1^{\circ}C$, $3.9{\sim}11.0\;mgCO_2kg^{-1}h^{-1}$ at $11^{\circ}C$ and $8.0{\sim}32.0\;mgCO_2kg^{-1}h^{-1}$ at $21^{circ}C$, respectively. The differences of the respiration rates with CPVM were smaller than those with PVM. CPVM, therefore, were more exact and convenient method than PVM in the measurement of respiration rate of fresh produce.

  • PDF

Development of VOCs Treatment Technology using High Efficiency Hybrid System with Multi-Scrone (멀티 선회류식 세정장치를 이용한 고효율 하이브리드 VOCs 습식처리 SYSTEM 개발)

  • Lim, Seong-Il;Kim, Nor-Jung;Kim, Sun-Mi;Lee, Seong-Hun;Kim, Sun-Uk;Chang, Won-Seok;Park, Dae-Won;Kim, Lae-Hyun;Kim, Jae-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.491-498
    • /
    • 2009
  • We studied to develop high-efficiency removal system of odor and VOCs(Volatile Organic Compounds) from environmental infrastructure facilities and oil refineries, painting facilities and so on. It can replace RTO and RCO. We tried an removal experiment for VOCs (toluene, xylene, benzene, MEK(methyl ethyl ketone), ethanol, formalin etc. and odor compounds (hydrogen sulfide, etc.). In process, as pre-treatment we used the scrubber with vortex flow (Multi-scrone) to remove the hydrophilic VOCs and as post-treatment, used fibrous bio-filter to remove the hydrophobic VOCs. This hybrid system remove with high efficiency both the hydrophilic VOCs and hydrophobic VOCs. And we tried to make this system to be compact. In experiment using Multi-scrone, contact time is 2~3 seconds and absorption scrubbing water is diaphragm-type electrolysis water. hydrophilic VOCs like ethanol and relatively hydrophilic odor compounds like hydrogen sulfide is excellent, these substances has been removed almost completely, respectively 95~99%, 93~97%. And for MEK, formalin also Showed a high removal efficiency, respectively 78~90%, 72~85%. But in experiment using Multi-scrone, the hydrophobic VOCs like BTX showed a low removal efficiency, respectively 16~22%, 12~18%, 8~16%. In hydrophobic VOCs, toluene removal experiment using fibrous bio-filter, early efficiency was low but after 10days, adaptation period showed high efficiency 85~95%. but in the mixed phase, toluene and MEK efficiency reduced 5~10%. this show microorganism treat first MEK easy to remove. The removal efficiency for MEK using the fibrous biofilter was stable, 80~92%. This hybrid system is also high economical efficiency for RTO. This system reduce more than 50% the cost of equipment and maintenance. As a result, we expect this technology is in the limelight as high efficiency treatment of VOCs in mid-low price.