• Title/Summary/Keyword: scroll

Search Result 378, Processing Time 0.024 seconds

Diagnostics and Prognostics Based on Adaptive Time-Frequency Feature Discrimination

  • Oh, Jae-Hyuk;Kim, Chang-Gu;Cho, Young-Man
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1537-1548
    • /
    • 2004
  • This paper presents a novel diagnostic technique for monitoring the system conditions and detecting failure modes and precursors based on wavelet-packet analysis of external noise/vibration measurements. The capability is based on extracting relevant features of noise/vibration data that best discriminate systems with different noise/vibration signatures by analyzing external measurements of noise/vibration in the time-frequency domain. By virtue of their localized nature both in time and frequency, the identified features help to reveal faults at the level of components in a mechanical system in addition to the existence of certain faults. A prima-facie case is made via application of the proposed approach to fault detection in scroll and rotary compressors, although the methods and algorithms are very general in nature. The proposed technique has successfully identified the existence of specific faults in the scroll and rotary compressors. In addition, its capability of tracking the severity of specific faults in the rotary compressors indicates that the technique has a potential to be used as a prognostic tool.

Numerical Optimization of a Multi-blades Centrifugal Fan for High-efficiency Design (원심다익송풍기의 고효율 설계를 위한 수치최적설계)

  • Seo, Seoung-Jin;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.3 s.24
    • /
    • pp.32-38
    • /
    • 2004
  • Shape of a multi-blades centrifugal fan is optimized by response surface method based on three-dimensional Navier-Stokes analysis. For numerical analysis, Reynolds-averaged Navier-Stokes equations with standard $k-{epsilon}$ turbulence model are transformed into non-orthogonal curvilinear coordinate system, and are discretized with finite volume approximations. Due to the large number of blades in this centrifugal fan, the flow inside of the fan is regarded as steady flow by introducing the impeller force models for economic calculations. Optimizations with and without constraints are carried out. Design variables, location of cur off, radius of cut off, expansion angle of scroll and width of impeller were selected to optimize the shapes of scroll and blades. Data points for response evaluations were selected by D-optimal design, and linear programming method was used for the optimization on the response surface. As a main result of the optimization, the efficiency was successfully improved. The correlation of efficiency with relative size of inactive zone at the exit of impeller is discussed as well as with average momentum fluxes in the scroll.

The Synchronization and Secure Communication of Hyper-chaos circuit using SC-CNN (SC-CNN을 이용한 하이퍼카오스 회로에서의 동기화 및 비밀 통신)

  • 배영철;김주완
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1064-1068
    • /
    • 2002
  • In this paper, we introduce a hyper-chaos synchronization method using State-Controlled Cellular Neural Network(SC-CNN). We make a hyper-chaos circuit using SC-CNN with the n-double scroll. A hyper-chaos circuit is created by applying identical n-double scrolls with weak coupled method, to each cell. Hyper-chaos synchronization was achieved using drive response synchronization between the transmitter and receiver about each state in the SC-CNN. From the result of the recovery signal through the demodulation method in the receiver, We shown that recovery quality of state variable $$\chi$_3$ is superior to that of ${$\chi$_2}, {$\chi$_1}$ in secure communication.

PIV Measurement of Flow Inside of HVAC Blower Unit (자동차 HVAC용 Blower Unit 내부 유동장의 PIV 계측)

  • Ji, Ho-Seong;Kim, Bo-Ram;Lee, Sang-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.165-173
    • /
    • 2007
  • Flow characteristics inside a blower unit of an automotive HVAC module were investigated experimentally using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser, a high-resolution CCD camera, optics and a synchronizer. The prototype siroco-fan with forward-curved blades was operated under the same condition of real car. The scroll casing was made transparently for capturing clear flow images. The time-averaged velocity fields were measured in three cross sections. Flow is accelerated with going toward the outer wall of scroll due to centrifugal force and large pressure gradient formed in the region between the fan and the outer casing wall. The presence of the cut-off region and diffusing duct of fan outlet influences largely the flow structure inside the blower unit.

Performance Improvement of a Scroll Compressor by Heat Transfer Analysis (열전달 해석을 통한 스크롤 압축기 성능 개선)

  • Hong, S. W.;Rew, H. S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.22-29
    • /
    • 2000
  • Numerical analysis using three dimensional finite volume method for the discretization, adaptive grid method for the numerical accuracy, multiple rotating frame method for the rotating body and the standard $k-{\epsilon}$ model for the turbulent flow was performed to understand the heat transfer phenomena and to improve the efficiency of the scroll compressor. The temperature measurement was carried out under ARI condition. It was found that the fluid temperature in the compressor was predicted accurately while the temperature of the motor coil showed large discrepancy between the calculation and experiment due to the large anisotropy of the conductivity and non homogeneity. We found that the efficiency of the compressor depends on the inlet temperature of the compressing part and the flow pattern around the inlet region of the compressing part influences the inlet temperature due to high surface temperature of the main frame. The efficiency of the compressor using Coanda effect is higher than the previous one because the smooth suction at the inlet region of the compressing part leads to low heat transfer to the refrigerant of the compressor.

  • PDF

A study on Secure Communication in Hyper-Chaos with SC-CNN using Embedding Method

  • Bae, Young-Chul;Kim, Ju-Wan;Song, Hag-Hyun;Kim, Yoon-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.4
    • /
    • pp.223-228
    • /
    • 2003
  • In this paper, we introduce a hyper-chaos secure communication method using hyper-chaos circuit onsist of State-Controlled Cellular Neural Network SC-CNN). We make a hyper-chaos circuit using SC-CNN with the n-double scroll or Chua's oscillator. A hyper-chaos circuit is created by applying identical n-double scroll or non-identical n-double scroll and Chua's oscillator with weak coupled method to each cell. Hyper-chaos ynchronization was achieved using GS (Generalized Synchronization) method between the transmitter and receiver about each state variable in the SC-CNN. In order to secure communication, we have synthesizing the desired information with a hyper-chaos circuit by adding the information signal to the hyper-chaos signal using the SC-CNN in the transmitter. And then, transmitting the synthesized signal to the ideal channel, we confirm secure communication by separating the information signal and the hyper-chaos signal in the receiver.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

A Theoretical Study on Driving Distance of Compressed Air Vehicle Using Scroll Expander (스크롤 팽창기를 적용한 압축공기 엔진 자동차의 주행거리 특성에 관한 연구)

  • Shin, Donggil
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.170-175
    • /
    • 2016
  • An internal combustion engine is the most widely used power source for an automobile. In order to resolve environmental problems resulting from the use of internal combustion engines, environmentally friendly automobiles such as hybrid, electric, and air-engine vehicles are being developed. The share of hybrid vehicles using battery or pure electric vehicles, which are not popular, is gradually increasing. Compared to an electric vehicle, which uses an electric motor, air-engine vehicles, which use compressed air, have hardly been developed. In this study, a compressed air engine with a scroll expander is introduced, and the potential mileage of an automobile utilizing this engine is theoretically calculated.

An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner (에어컨용 직교류홴 시스템의 성능특성에 대한 기본적 설계변수의 영향에 관한 실험적 연구)

  • Koo, Hyoung Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.695-702
    • /
    • 1999
  • A cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll-casing is widely used in many air-ventilating and air-conditioning devices. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the devices, which means many difficulties during the design stage of the devices and the general design guide has not sufficiently established yet. This study presents the experimental results of the parameter investigation of some chosen design parameter values, which are the shapes of the stabilizers, the profiles of the scroll casing part, and the diffusion angles of the flow exit. The results are expressed by the varying performance characteristics with the values of the parameters. They are found to have considerable effects on the system performance and should be considered with care in the design stage. Finally some helpful guides for the design and manufacturing of the cross-flow fan system are proposed.

Approximate Multi-Objective Optimization of Scroll Compressor Lower Frame Considering the Axial Load (축하중을 고려한 스크롤 압축기 하부 프레임의 최적설계)

  • Kim, JungHwan;Lee, Jongsoo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.308-313
    • /
    • 2015
  • In this research, a multi-objective optimal design of a scroll compressor lower frame was approximated, and the design parameters of the lower frame were selected. The sensitivity of the design parameters was induced through a parameter analysis, and the thickness was determined to be the most sensitive parameter to stress and deflection. All of the design parameters regarding the mass are sensitive factors. It was formulated for the problem about stress and deflection to be caused by the axial load. The sensitivity of the design variables was determined using an orthogonal array for the parameter analysis. Using the central composite and D-optimal designs, a second polynomial approximation of the objective and constraint functions was formulated and the accuracy was verified through an R-square. These functions were applied to the optimal design program (NSGA-II). Through a CAE analysis, the effectiveness of the central composite and D-optimal designs was determined.