• 제목/요약/키워드: screws

검색결과 646건 처리시간 0.025초

하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES)

  • 구제훈;김일규;장재원;양정은;사시카라 바라라만;왕붕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

TiN 및 WC코팅된 치과용 어버트먼트 나사의 안정성 (Stability of TiN and WC Coated Dental Abutment Screw)

  • 손미경;이충환;정재헌;정용훈;최한철
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.292-300
    • /
    • 2008
  • Dental implant system is composed of abutment, abutment screw and implant fixture connected with screw. The problems of loosening/tightening and stability of abutment screw depend on surface characteristics, like a surface roughness, coating materials and friction resistance and so on. For this reason, surface treatment of abutment screw has been remained research problem in prosthodontics. The purpose of this study was to investigate the stability of TiN and WC coated dental abutment screw, abutment screw was used, respectively, for experiment. For improving the surface characteristics, TiN and WC film coating was carried out on the abutment screw using EB-PVD and sputtering, respectively. In order to observe the coating surface of abutment screw, surfaces of specimens were characterized, using field emission scanning electron microscope(FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The stability of TiN and WC coated abutment screw was evaluated by potentiodynamic, and cyclic potentiodynamic polarization method in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion potential of TiN coated specimen was higher than those of WC coated and non-coated abutment screw. Whereas, corrosion current density of TiN coated screws was lower than those of WC coated and non-coated abutment screw. The stability of screw decreased as following order; TiN coating, WC coating and non-coated screw. The pitting potentials of TiN and WC coated specimens were higher than that of non-coated abutment screw, but repassivation potential of WC coated specimen was lower than those of TiN coated and non-coated abutment screws due to breakdown of coated film. The degree of local ion dissolution on the surface increased in the order of TiN coated, non-coated and WC coated screws.

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

원위 상완골 분쇄 골절의 수술적 치료 결과 (The Results of Surgical Treatment of Comminuted Fractures of Distal humerus)

  • 조남수;박성우;정기연;이용걸
    • Clinics in Shoulder and Elbow
    • /
    • 제8권2호
    • /
    • pp.97-104
    • /
    • 2005
  • Purpose: To report the results of surgical treatment of comminuted fractures of distal humerus and to identify factors that affect the results. Materials and Methods: Thirty-two patients who were treated with open reduction and internal fixation for comminuted fracture of distal humerus were enrolled. According to the AO classification, A2.3 was 1 case, A3.2, 2 cases, A3.3, 8 cases, B1.3, 1 case, B2.3, 1 case, C2.2, 5 cases, C2.3, 4 cases, C3.2, 3 cases and C3.3, 7 cases. As fixation technique, 17 cases were fixed by double plates, 4 cases by only K-wires, 4 cases by only screws, 3 cases by K-wires and screws and 4 cases by one plate and screws. The mean age at the time of the operation was 49 years(range, $19{\sim}77$ years). The mean follow-up period was 16 months(range, $8{\sim}51$ months). Results: At the last follow-up, the mean maximum flexion was $116.4^{\circ}\;(range,\;85{\sim}140^{\circ})$ and the mean loss of terminal extension was $11.8^{\circ}\;(range,\;0{\sim}40^{\circ})$. The average Mayo elbow performance score was $91.4^{\circ}\;(range,\;55{\sim}100^{\circ})$. Overall 29 cases(91%) showed good to excellent results. The mean range of motion of extraarticular and intraarticular fracture group was $105.5^{\circ}\;(range,\;65{\sim}140^{\circ})$ and $104^{\circ}\;(range,\;55{\sim}140^{\circ})$, respectively. The average elbow score of both groups was$93^{\circ}\;(range,\;70{\sim}100^{\circ})$ and $90.7^{\circ}\;(range,\;55{\sim}100^{\circ})$. Over 90% showed more than good results. 30 cases(94%) showed complete bony union but two cases, nonunion. One case of the nonunion cases underwent replating with bone graft as revision surgery and total elbow arthroplasty was performed in the other case. At the last follow-up, 27 patients(84.4%) showed subjective satisfaction. Conclusion: Open reduction and internal fixation with appropriate surgical technique for comminuted fractures of distal humerus showed good results, which were not affected by age at the time of operation, fixation methods and anterior transposition of the ulnar nerve. Transolecranon approach may be considered as good choice for intraarticular comminuted fractures of distal humerus.

하악지시상분할골절단술 시행 후 von-Miese 항복강도에 대한 유한요소법적 연구 (A STUDY OF VON-MISES YIELD STRENGTH AFTER MANDIBULAR SAGITTAL SPLIT RAMUS OSTEOTOMY)

  • 윤옥병;김여갑
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권3호
    • /
    • pp.196-204
    • /
    • 2002
  • For the study of its stability when the screw has been fixed after sagittal split ramus osteotomy(SSRO) of the mandible, the methods of screw arrangement are classified into two types, triangular and straight. The angles of screws to the bone surface are classified as perpendicular arrangements, the $60^{\circ}$ anterioinferior screw, known as triangular, and the most posterior screw, called straight arrangement, thus there are four types. The finite element method model has been made by using a three dimensional calculator and a supercomputer. The load directions are to the anterior teeth, premolar region, and molar region, and the bite force is 1 Kgf to each region. The distribution of stress, the von-Mises yield strength, and safety of margin refer to the total sum of transformed energy have been studied by comparison with each other. The following conclusion has been researched : 1. When shear stress is compared, in the triangular arrangement in the form of "ㄱ", the anterosuperior screw is seen at contributing to the support of the bone fragment. In the straight arrangement, substantial stress is seen to be concentrated on the most posterior angled screw. 2. When the von-Mises yield strength is compared, it seemed that the stress concentration on the angled anteroinferior screw is higher, it shows a higher possibility of fracture than any other screw. In the straight arrangement, stress appeared to be concentrated on the most posteriorly angled screw. 3. When the safety margins of the transfomed energy are compared, the energy conduction is much greater in the case of the angled screw than in the case of the perpendicular screw. The triangular arrangement in the form of "ㄱ" shows a superior clinical sign to that of the straight arrangement. Judging from the above results, when the screw fixation is made after SSRO in practical clinical cases, two screws should be inserted in the superior border of mandibular ramus and a third screw of mandibular inferior border should be inserted in the form of triangular. All screws on the bony surface should be placed perpendicularly-$90^{\circ}$ angles apparently best promote bony support and stability.

임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가 (EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS)

  • 최정한
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

단일치 임플랜트 지지 보철물에서 고정체와 지대주 나사 직경의 차이에 따른 삼차원 유한요소법적 응력 분석 (THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT RESTORATION USING DIFFERENT FIXTURE AND ABUTMENT SCREW DIAMETERS)

  • 권주홍;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.105-119
    • /
    • 2005
  • Statement of problem. As the effects of the various diameters of fixture and abutment screw on stress distribution was not yet examined, this study focused on the different design of single implant restoration using three dimensional finite element analysis. Purpose. This study was to compare five different fixture-abutment combinations for single implant supported restorations with different fixture and abutment screw diameters. Material of methods. The five kinds of finite element models were designed by 3 diameter fixtures ($\oslash$3.3, 3.75, 5.0 mm) with 3 different abutment screws $\oslash$1.5, 1.7, 2.0 mm). The crown for mandibular first molar was made using UCLA abutment according to Wheeler's anatomy. 244 N was applied at the central fossa with two different loading directions, vertically and obliquely (30$^{\circ}$) and at the buccal cusp vertically. Maximum von Mises stresses were recorded and compared in the supporting bone, crowns, fixtures, and abutment screws. Results. 1. The stresses in supporting bone and implant-abutment structure under oblique loading were greater than those under vertical or offset loading. The stresses under vertical loading were the least among 3 loading conditions regardless of the implant and abutment screw diameters. 2. The stresses in the narrow implants were greater than the wider implants. The narrow implant with narrow abutment screw showed highest stresses in the lingual crest, but the narrow implant with standard abutment screw showed highest stress in abutment screw. 3. The stresses of abutment screws were influenced by the diameter of fixtures and loading conditions. The wide implants showed least difference between two different abutment screw diameters. Conclusions. The wide implants showed lesser stresses than the narrow implants and affected least by the different abutment screw diameters. The narrow implants with standard abutment screw showed highest stresses in the lingual bony crest under oblique loading.

말티즈 견에서 Screw, Wire와 PMMA를 사용한 외상성 경추 골절의 안정화 (Stabilization using Screws, Wire, and PMMA for Traumatic Cervical Fracture in a Maltese Dog)

  • 김근영;김민경;박지훈;신정인;김준수;장윤설;이재훈
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.519-522
    • /
    • 2014
  • 2년령 2 kg 말티즈가 진행성 사지마비와 목의 통증으로 내원하였다. 개는 알 수 없는 외상 이후 지난 2주간 스테로이드로 처치되었으나 점진적으로 상태가 악화되었고, 사지마비 상태가 되었다. 내원 시 개는 보행이 불가능한 사지마비 상태를 보였다. 방사선 사진과 CT 결과, C2의 가로골절과, 환추관절과 C2-C3의 불완전 탈구가 발견되었다. 추가적으로, MRI 상에서 뇌수종이 관찰되었다. Screw, Wire 와 PMMA를 사용한 C1-C3의 안정화가 시행되었다. 수술 후 4주에 임상 증상이 개선되었고, 개는 수술 6주 후에 이전과 마찬가지로 보행이 가능하였다. 본 증례의 Screw, Wire 와 PMMA를 안정화로 경추 골절을 효과적으로 치료하였다.