• 제목/요약/키워드: screw fixation

검색결과 437건 처리시간 0.027초

요추전방전위증 환자들에서 후방요추체간유합술로 자가골편 또는 Cage를 사용한 두 군간의 비교 (Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients)

  • 신필재;김창현;문재곤;이호국;황도윤
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : Posterior lumbar interbody fusion(PLIF) with transpedicular screw fixation(TPSF) have many merits in the treatment of spondylolisthesis. The aim of this study was to compare cage PLIF group(PLIF using cage and TPSF) with chip PLIF group(PLIF using autologous bone chips and TPSF) as surgical treatment of spondyloisthesis. Methods : PLIF and TPSF were performed in 44 patients with spondylolisthesis from January 1994 to December 1998. The surgical methods were divided into two groups. One group was cage PLIF(20 patients), and the other group was chip PLIF(24 patients). We analyzed the change of anterior translation, change of intervertebral space height, fusion rate, clinical outcomes, and postoperative complications in two groups. Result : There was no significant difference in reduction and maintenance of anterior translation between two groups. Intervertebral space height was increased in the two groups at immediate postoperative state. At last followup, it was decreased compared to preoperative height in chip PLIF group. In cage PLIF group, last follow-up height was decreased compared to immedate postoperative height, but it was significantly increased compared to preoperative height. Fusion rates were 70.9% and 90% in chip PLIF group and cage PLIF group, respectively. Excellent and good clinical outcomes were 79.2% in chip PLIF group and 85% in cage PLIF group, but there was no statistical significance. Complications were screw fracture(1 case), CSF leakage(1 case) in chip PLIF group and screw loosening and retropulsion of cage(1 case), CSF leakage(2 cases) in cage PLIF group. Conclusion : PLIF using cage is better than PLIF using autologous bone chips in the maintenance of intervertebral space height and fusion rate. But there is no statistical difference of the clinical outcomes between the two groups. Further studies, especially on long term follow-up, should be considered.

  • PDF

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.

슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장 (Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw)

  • 송은규;윤택림;정종욱;정광철
    • 대한관절경학회지
    • /
    • 제5권2호
    • /
    • pp.69-73
    • /
    • 2001
  • 목 적 : 대퇴부의 고정을 위해 새로이 고안된 Ligament Anchor(LA) 나사와 슬괵건을 이용한 전방십자인대 재건술 후 임상결과와 골터널의 확장을 평가하고자 하였다. 대상 및 방법 : 슬괵건 4가닥과 LA 나사를 이용하여 전방십자인대 재건술 후 최소 2년 이상 추시 가능하였던 58예를 대상으로 하였다. 이식건의 고정으로 대퇴골측은 LA나사를, 경골측은 생흡수성 간섭나사를 이용하였다 평균 추시기간은 28개월이었다. 임상적 결과로는 Lachmann 검사와 Lysholm 점수를 이용하였으며 방사선학적 결과로는 골터널의 확대정도와 $Telos^{\circledR}$ 기기(Telos stress device; Austin & Associates, Inc., Polston, US)를 이용한 전방 전위 방사선 사진을 촬영하여 건측과의 전방이완도 차이를 평가하였다. 결과 : Lysholm 점수는 술 전 평균 60에서 술 후 평균 94.0점으로 호전되었으며, 술 전 Lachmann 검사상 16예에서 경도의 양성, 24예에서 중등도, 18예에서 고도의 양성 소견을 보였으며, 술 후 Lachmann 검사상 50예는 음성이었으며, 8예에서만 경도의 양성소견을 보였다. $Telos^{\circledR}$ 기기를 이용한 전방전위 검사상 건측과의 차이는 술전 평균 12.9mm에서 최종 추시상 3.1mm로 호전되었다(p<0.05). 대퇴 터널은 전후방 방사선 사진상 수술직후 10.6mm에서 최종 추시상 12.7mm$(21.1\%)$로 확장되었으며, 측면 방사선 사진상 술 후 10.7mm에서 최종 추시상 12.4mm$(16.5\%)$로 확장되었다(p<0.05). 경골 터널은 전후방 방사선 사진상 술 후 9.8mm에서 최종 추시상 11.8mm$(20.7\%)$로 확장되었으며 측면 방사선 사진상 술 후 9.9mm에서 최종 추시상 11.7mm$(18.9\%)$로 확장되었다(p<0.05). 결론 : LA나사와 슬괵건을 이용한 전방십자인대 재건술은 골터널의 확장이 적으며 임상 성적도 우수하여 슬관절의 전방 안정성을 회복하는데 좋은 이식물 및 내고정물이라 생각된다.

  • PDF

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.

구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구 (A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY)

  • 김일규;박승훈;장금수;양정은;장재원;사시카라 바라라만
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

진구성 전방 십자 인대 견열 골절의 수술적 치료 (The Surgical Treatment of Chronic Avulsion Fracture of the Anterior Cruciate Ligament)

  • 송은규;설종윤;최진
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.31-36
    • /
    • 2002
  • 목적 : 진구성 전방 십자 인대 견열 골절의 치료후 임상적, 방사선학적 결과를 평가하고자 하였다. 대상 및 방법 : 손상후 3개월 이상 지난 진구성 전방 십자 인대 견열 골절로 진단 받고 본원에서 치료받은 환자중 2년 이상 추시 관찰이 가능하였던 11예를 대상으로 하였으며 평균 연령은 26세(9-66)이었고 평균 추시 기간은 53개월(24-131)이었다. 수술은 전 예에서 관절경하에 병변의 확인 및 동반 손상의 치료후 관혈적 정복을 통한 내고정이나 골편 제거술을 시행하였다. 고정 방법은 8예에서 견인 봉합술을 2예에서 나사못 고정을 시행하였다. 결과 : Lysholm knee score는 술전 평균 64.3점에서 술후 96.2점으로 호전되었으며, 술전 Lachman 검사상 7예에서 경도의 양성, 4예에서 중등도의 양성 소견을 보였으며 술후 Lachman 검사상 9예는 음성이었으며, 2예에서 경도의 양성소견을 보였다. Meyers와 Mckeever의 평가 기준에 의하면 9예$(81.8\%)$에서 우수, 2예$(18.2\%)$에서 양호의 결과를 보였다. $Telos^{\circledR}$기기를 이용한 건측과의 전방이완도 차이의 평가에서 술전 평균 7.8(10-4)mm의 차이를 보였으며 술후 최종 추시상 평균 2.1(6-0)mm의 차이를 보였다. 결론 : 진구성 전방 십자 인대 견열 골절에 대한 치료에 있어 관절경 검사를 통해 동반 손상의 평가와 관절 절개술을 통해 해부학적 정 복과 고정 또는 골편 제거를 병행함으로서 만족할만한 결과를 얻을 수 있을 것으로 생각된다.

  • PDF

상완골 소두 골절의 치료결과 (Treatment Results of Capitellum Fractures)

  • 박진수;정영기;유정한;노규철;정국진;정성욱
    • 대한정형외과스포츠의학회지
    • /
    • 제4권2호
    • /
    • pp.116-121
    • /
    • 2005
  • 목적: 상완골 소두 골절은 매우 희귀한 골절의 형태인데 관절면의 침범으로 인해 적극적인 수술적 치료가 요한다. 이러한 상완골 소두 골절의 관혈적 정복 후 내고정 후의 결과를 보고하는 바이다. 대상 및 방법: 1998년부터 2004년 까지 상완골 소두 골절로 수술 시행받은 4명의 환자를 대상으로 하였다. Morrey의 분류법 상 제 1형이 3례, 제 3형이 1례였다. 전 례에서 주관절의 외측 도달법을 사용하였으며, 관혈적 정복후 유관 나사못 고정을 실시하였다. 수술후 주관절의 부목등의 고정은 4일에서 28일 까지 소요되었다. 최종 추시 판정 시 Mayor의 주관절 기능 평가 방법을 이용하여 주관절 운동 범위, 주관절의 안정성, 동통 유무 등을 평가하였다. 결과: 평균 추시기간은 12개월에서 36개월이었으며 평균 15개월(12개월-36개월) 이었다. 3례의 경우 견고한 골고정을 얻었으며 우수한 관절 운동범위를 얻을 수 있었다. 그러나 만성 소두골 골절 및 부정유합으로 내원하였던 1 례의 경우 추시 관찰동안 재활에 순응하지 않아서 40도-100도의 운동범위만을 보여주었다. 전 례에서 무혈성 괴사나 주관절 관절염의 소견은 보이지 않았다. 결론: 상완골 소두 골절은 희귀하지만 적극적으로 관혈적 정복 및 내고정시 우수한 결과를 보여 줄 수 있었다.

  • PDF

Long-term Stability after Reduction of Mandible Fracture by Keyhole Plate: Evaluation at the Time of Plate Removal

  • Cheon, Kyeong-Jun;Cho, Seoung-Won;Jang, Won-Seok;Kim, Ju-Won;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.6.1-6.6
    • /
    • 2020
  • Background: Various types of miniplates have been developed and used for the reduction of facial bone fractures. We introduced Yang's Keyhole (YK) plate, and reported on its short-term stability. The purpose of this study was to evaluate the long-term stability of the YK plate, as a follow-up study, by examining the patients who had used the YK plate among the patients with the reduction of mandible fractures and who visited for plate removal. Methods: We reviewed the medical records of 16 patients who underwent mandibular fracture fixation using a YK plate (group I) and 17 patients who underwent mandibular fracture fixation using a conventional plate (group II). Assessment was then made on malunion, occlusal stability, discomfort during the application, and clinical symptoms. Results: From January 2015 to December 2017, a total of 36 patients underwent mandibular fracture surgery using a YK plate. A total of 16 patients received plate removal. Among them, 15 were male and 1 female. The average age was 26 years. The applied surgical sites were the 12 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of YK plate was an average of 335 days. During the same period, 45 people underwent surgery on the conventional plate. A total of 17 patients received plate removal. Among them, 15 were male and 2 females. The average age was 36 years. The applied surgical sites were the 8 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of the conventional plate was an average of 349 days. No malocclusion occurred at the time of removal, and occlusion was stable. No patient complained of joint disease or discomfort. Conclusion: The YK plate system, in which the screw was first inserted and the plate was applied, for clinical convenience did not cause any particular problem and no significant difference from the conventional plate.

인장대 강선 고정술을 이용한 제5 중족골 기저부 골절의 수술적 치료 (Treatment of Fifth Metatarsal Base Fracture Using Tension Band Wiring)

  • 안종국;정형진;배서영;박지용
    • 대한족부족관절학회지
    • /
    • 제15권1호
    • /
    • pp.18-21
    • /
    • 2011
  • Purpose: To evaluate the clinical and radiological results of internal fixation with tension band wiring for the fracture at the base of fifth metatarsal bone. Materials and Methods: From January 2008 to December 2009, 15 cases with displaced fracture at the base of fifth metatarsal were analyzed and average follow up period was 13.8 months. Lawrence classification was used to classify fracture type. We evaluated clinical results by American Orthopedic Foot Ankle Society (AOFAS) midfoot score and radiological results by union time. Complications was also checked. Results: According to classification, zone I fracture were 11 cases and zone II fracture were 4 cases. Bony union was achieved in all cases after 7 weeks. In the final follow-up, average AOFAS score was 94. There were no complications except hardware irritation. Conclusion: Satisfactory results were obtained after tension band wiring for the fifth Metatarsal base fracture in zone I fracture or comminuted zone II fracture for which it is not easy to be fixed with screw.

Danis-Weber B형 족근 관절 골절에 있어 유경 나사를 이용한 비골 외 과 골절의 치료 (Treatment of Lateral Malleolar Fractures with Cannulated Screws in Danis-Weber type B Ankle Fractures)

  • 박용욱;정영기;유정한;박홍준;유선오;강기만
    • 대한족부족관절학회지
    • /
    • 제5권2호
    • /
    • pp.129-135
    • /
    • 2001
  • Purpose: To evaluate the radiographic results of the treatment for Danis-Weber type B lateral malleolar fracture with 2 cannulated screws. Materials and Methods: Thirty-four cases of Danis-Weber type B lateral malleolar fracture were available. Follow-up averaged 8 months (6-25 months). The medial clear space for lateral displacement of talus, talo-crural angle for lateral malleolar shortening, and malunion evidence of lateral malleolar fracture were observed. Results: Medial clear space was from 2mm to 4mm in 34 cases. Talo-crural angle was from $73^{\circ}$ to $82.5^{\circ}$ in 33 cases. One case was complicated with malunion of lateral malleolus. But, we found the same condition in the immediate post- operative radiographic film. Conclusion: We believe that the 2 cannulated screws fixation for Danis-Weber type B lateral malleolar simple fractures is an excellent treatment method.

  • PDF