• Title/Summary/Keyword: screw fixation

Search Result 437, Processing Time 0.066 seconds

Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients (요추전방전위증 환자들에서 후방요추체간유합술로 자가골편 또는 Cage를 사용한 두 군간의 비교)

  • Shin, Pill Jae;Kim, Chang Hyun;Moon, Jae Gon;Lee, Ho Kook;Hwang, Do Yun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : Posterior lumbar interbody fusion(PLIF) with transpedicular screw fixation(TPSF) have many merits in the treatment of spondylolisthesis. The aim of this study was to compare cage PLIF group(PLIF using cage and TPSF) with chip PLIF group(PLIF using autologous bone chips and TPSF) as surgical treatment of spondyloisthesis. Methods : PLIF and TPSF were performed in 44 patients with spondylolisthesis from January 1994 to December 1998. The surgical methods were divided into two groups. One group was cage PLIF(20 patients), and the other group was chip PLIF(24 patients). We analyzed the change of anterior translation, change of intervertebral space height, fusion rate, clinical outcomes, and postoperative complications in two groups. Result : There was no significant difference in reduction and maintenance of anterior translation between two groups. Intervertebral space height was increased in the two groups at immediate postoperative state. At last followup, it was decreased compared to preoperative height in chip PLIF group. In cage PLIF group, last follow-up height was decreased compared to immedate postoperative height, but it was significantly increased compared to preoperative height. Fusion rates were 70.9% and 90% in chip PLIF group and cage PLIF group, respectively. Excellent and good clinical outcomes were 79.2% in chip PLIF group and 85% in cage PLIF group, but there was no statistical significance. Complications were screw fracture(1 case), CSF leakage(1 case) in chip PLIF group and screw loosening and retropulsion of cage(1 case), CSF leakage(2 cases) in cage PLIF group. Conclusion : PLIF using cage is better than PLIF using autologous bone chips in the maintenance of intervertebral space height and fusion rate. But there is no statistical difference of the clinical outcomes between the two groups. Further studies, especially on long term follow-up, should be considered.

  • PDF

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

The Surgical Treatment of Chronic Avulsion Fracture of the Anterior Cruciate Ligament (진구성 전방 십자 인대 견열 골절의 수술적 치료)

  • Song Eun-Kyoo;Seol Jong-Yoon;Choi Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the clinical and radiological results after treatment of old ACL(anterior cruciate ligament) avulsion fracture of tibia. Materials and Method : 11 cases who were followed up at least 2 years after treatment in chronic ACL avulsion fracture of tibia were included in this study. The average age of patients was 26(9-66) years and the mean period of follow up was 53(24-131) months. After evaluation of the lesion and treatment of associated lesion under arthroscope, open reduction and internal fixation or fragment removal was performed. Pull-out suture was performed in 8 cases, screw fixation in 2 cases. Results : The Lysholm knee score was 64.3 in average preoperatively and improved to 96.2 average at follow up. On the Lachman test, there were mild(+) instabilities in 7 cases, moderate(++) in 4 cases. On the postoperative Lachman test, there were no instabilities in 9 cases, mild(+) instabilities in only 2 cases. According to Meyers and Mckeever's evaluation protocol, 9 cases $(81.8\%)$ were excellent, 2 case $(18.2\%)$, good. On preoperative instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 201b was 7.8(10-4) min in average and 2.1(6-0) mm in average at follow-up. Conclusion : In chronic ACL avulsion fracture, it is thought that combination of arthroscopic evaluation of associated injury and open reduction and fixation and fragment removal can bring about satisfactory results.

  • PDF

Treatment Results of Capitellum Fractures (상완골 소두 골절의 치료결과)

  • Park, Jin-Soo;Chung, Yung-Khee;You, Jung-Han;Noh, Gyu-Cheol;Chung, Kook-Jin;Jung, Sung-Ook
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.2
    • /
    • pp.116-121
    • /
    • 2005
  • Purpose: Isolated capitellar fractures are rare, intra-articular fractures requiring an aggressive management regimen. Review the outcome after open reduction and internal fixation of the capitellar fractures. Materials and Methods: From 1998 to 2004, 4 patients with displaced fractures of the humeral capitellum were treated by open reduction and internal fixation of the capitellar fragments with cannulated screws. By use of the criteria of Bryan and Morrey et al, there were 3 type I fractures, 1 type III fracture. A lateral approach was used. The elbows were immobilized postoperatively for 4 to 28 days We evaluated the range of motion, stability, and pain using the criteria of Mayo score. Results: The follow-up period ranged from 12 to 36 months (mean, 15months). Three patients had a stable, pain-free elbow with good range of motion at follow-up. One patient with a neglected capitellar fracture have felxtion cpontracture of 40 degrees with 100 degrees of further felxion(total arc: 60) due to poor compliance to the postoperative rehabilitation. All fractures healed, and there was no evidence of avascular necrosis or degenerative change. Conclusion: Capitellar fractures, rare in case, gave a good result after open reduction and simple internal fixation with cannulated screws without any problem.

  • PDF

Long-term Stability after Reduction of Mandible Fracture by Keyhole Plate: Evaluation at the Time of Plate Removal

  • Cheon, Kyeong-Jun;Cho, Seoung-Won;Jang, Won-Seok;Kim, Ju-Won;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.6.1-6.6
    • /
    • 2020
  • Background: Various types of miniplates have been developed and used for the reduction of facial bone fractures. We introduced Yang's Keyhole (YK) plate, and reported on its short-term stability. The purpose of this study was to evaluate the long-term stability of the YK plate, as a follow-up study, by examining the patients who had used the YK plate among the patients with the reduction of mandible fractures and who visited for plate removal. Methods: We reviewed the medical records of 16 patients who underwent mandibular fracture fixation using a YK plate (group I) and 17 patients who underwent mandibular fracture fixation using a conventional plate (group II). Assessment was then made on malunion, occlusal stability, discomfort during the application, and clinical symptoms. Results: From January 2015 to December 2017, a total of 36 patients underwent mandibular fracture surgery using a YK plate. A total of 16 patients received plate removal. Among them, 15 were male and 1 female. The average age was 26 years. The applied surgical sites were the 12 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of YK plate was an average of 335 days. During the same period, 45 people underwent surgery on the conventional plate. A total of 17 patients received plate removal. Among them, 15 were male and 2 females. The average age was 36 years. The applied surgical sites were the 8 on mandibular angle, 4 on mandibular symphysis, and 2 on subcondyle. The application period of the conventional plate was an average of 349 days. No malocclusion occurred at the time of removal, and occlusion was stable. No patient complained of joint disease or discomfort. Conclusion: The YK plate system, in which the screw was first inserted and the plate was applied, for clinical convenience did not cause any particular problem and no significant difference from the conventional plate.

Treatment of Fifth Metatarsal Base Fracture Using Tension Band Wiring (인장대 강선 고정술을 이용한 제5 중족골 기저부 골절의 수술적 치료)

  • Ahn, Jong-Kuk;Chung, Hyung-Jin;Bae, Su-Young;Park, Ji-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.1
    • /
    • pp.18-21
    • /
    • 2011
  • Purpose: To evaluate the clinical and radiological results of internal fixation with tension band wiring for the fracture at the base of fifth metatarsal bone. Materials and Methods: From January 2008 to December 2009, 15 cases with displaced fracture at the base of fifth metatarsal were analyzed and average follow up period was 13.8 months. Lawrence classification was used to classify fracture type. We evaluated clinical results by American Orthopedic Foot Ankle Society (AOFAS) midfoot score and radiological results by union time. Complications was also checked. Results: According to classification, zone I fracture were 11 cases and zone II fracture were 4 cases. Bony union was achieved in all cases after 7 weeks. In the final follow-up, average AOFAS score was 94. There were no complications except hardware irritation. Conclusion: Satisfactory results were obtained after tension band wiring for the fifth Metatarsal base fracture in zone I fracture or comminuted zone II fracture for which it is not easy to be fixed with screw.

Treatment of Lateral Malleolar Fractures with Cannulated Screws in Danis-Weber type B Ankle Fractures (Danis-Weber B형 족근 관절 골절에 있어 유경 나사를 이용한 비골 외 과 골절의 치료)

  • Park, Yong-Wook;Chung, Yung-Khee;Yoo, Jung-Han;Park, Hong-Jun;Yu, Sun-O;Kang, Ki-Man
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.129-135
    • /
    • 2001
  • Purpose: To evaluate the radiographic results of the treatment for Danis-Weber type B lateral malleolar fracture with 2 cannulated screws. Materials and Methods: Thirty-four cases of Danis-Weber type B lateral malleolar fracture were available. Follow-up averaged 8 months (6-25 months). The medial clear space for lateral displacement of talus, talo-crural angle for lateral malleolar shortening, and malunion evidence of lateral malleolar fracture were observed. Results: Medial clear space was from 2mm to 4mm in 34 cases. Talo-crural angle was from $73^{\circ}$ to $82.5^{\circ}$ in 33 cases. One case was complicated with malunion of lateral malleolus. But, we found the same condition in the immediate post- operative radiographic film. Conclusion: We believe that the 2 cannulated screws fixation for Danis-Weber type B lateral malleolar simple fractures is an excellent treatment method.

  • PDF