• Title/Summary/Keyword: screen tests

Search Result 187, Processing Time 0.025 seconds

Development of a Portable Automatic Auditory Response Tester for Hearing Loss Screening (난청감별을 위한 휴대용 자동 청성반응 검사기의 개발)

  • Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.38-45
    • /
    • 2012
  • If an infant with congenital hearing loss is diagnosed in good time and get proper treatment as soon as possible, treatment effect could be maximized and the social costs could be considerably reduced. For these reasons, the medical equipment to screen hearing impairment objectively is needed. The ABR(auditory brainstem response) is typical diagnostic tools for this purpose but there are drawbacks in sense that it does not have frequency specificity and shows hearing information of usually high frequency band. The ASSR(auditory steady-state response) is excellent in frequency specificity, but the rate of wrong diagnosis is slightly high. In this study, we proposed the system which can measure both the ABR and the ASSR, and can show the objective and quantitative indices(Fsp and F-test). It was designed to allow various tests without hardware modification by minimizing hardware components and by increasing software roles. The objective assessment of the developed system was evaluated by experiments with 10 normal persons.

Varietal Variation in Germinative Energy, Capacity and Water Sensitivity for Malting Barley (맥주보리에서 발아세, 발아율 및 수감수성의 품종간 차이)

  • 천종은;이은섭
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.1
    • /
    • pp.62-67
    • /
    • 1986
  • Forty-nine malting barley varieties were tested at 3 and 8 weeks after harvest, stored in natural glasshouse so as to investigate varietal variation of germinative energy(GE), capacity(GC) and water sensitivity(WS). The differences among GE, GC, promptness index(PI), and WS on paper at two moisture levels (4$m\ell$ and 8$m\ell$ tests) were great at 3 weeks after harvest, but small at 8 weeks after harvest. Excess water depressed the germination of dormant grains. The GE of whole varieties were excellent, but WS of only two varieties, CI 12062 and CI 15631 were bad at 8 weeks after harvest. So in the case of broad germplasm to be used for crossing materials, it is suggested that WS will be tested to screen good quality malting lines. WS was highly significantly correlated with GE, GC, and PI of 8 ml test, but was not with three factors of 4 $m\ell$ test. GE and WS were various with storage period, varieties and grain plumpness, indicated that breeding good grain-filling varieties and improving production practice for good grain-filling would be studied in the future.

  • PDF

Isolation and Charcterization of Micrococcus sp. HJ-19 Secreting Extracellular Protease (단백질 분해효소를 분비하는 Micrococcus sp. HJ19의 분리 및 특성)

  • Cha, In-Tae;Oh, Yong-Sik;Roh, Dong-Hyun
    • Korean Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.222-226
    • /
    • 2007
  • Proteases are degradative enzymes which hydrolyze a peptide bond between amino acids and they are abundantly applied to commercial field. In order to screen new source of pretense, bacteria secreting extracellular pretense were isolated by enrichment culture from deep sea water samples of East Sea, Korea. A bacterium, named as HJ19, showed the best growth and the largest clear zone in plates supplemented skim milk at $30^{\circ}C$. The partial DNA sequence analysis of the 16S rRNA gene, phenotypic tests and morphology identified that this strain was In genus Micrococcus. The strain HJ19 could not grow at $10^{\circ}C$ but it started growth and showed pretense activity at $20^{\circ}C$. The optimal growth was at $37^{\circ}C$ and the maximal protease activity at $30^{\circ}C$ was about 480unit/ml.

Antimicrobial Activity of Medicinal Plants Against Bacillus subtilis Spore

  • Cho, Won-Il;Choi, Jun-Bong;Lee, Kang-Pyo;Cho, Seok-Cheol;Park, Eun-Ji;Chung, Myong-Soo;Pyun, Yu-Ryang
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.1072-1077
    • /
    • 2007
  • Bacterial endospores, especially those of Bacillus and Clostridium genera, are the target of sterilization in various foods. We used Bacillus subtilis ATCC 6633 spores to screen novel antimicrobial substances against spores from medicinal plants. We collected 79 types of plant samples, comprising 42 types of herbs and spices and 37 types of medicinal plants used in traditional medicine in Korea and China. At a concentration of 1%(w/v), only 14 of the ethanol extracts exhibited antimicrobial activity against B. subtilis spores of at least 90%. Crude extracts of Torilis japonica, Gardenia jasminoides, Plantago asiatica, Fritllaria, and Arctium lappa showed particularly high sporicidal activities, reducing the spore count by about 99%. Consideration of several factors, including antimicrobial activity, extraction yields, and costs of raw materials, resulted in the selection of T. japonica, G. jasminoides, A. lappa, and Coriandrum sativum for the final screening of novel antimicrobial substances. Verification tests repeated 10 times over a 4-month period showed that the ethanol extract of T. japonica fruit reduced aerobic plate counts of B. subtilis spores the most, from $10^7$ to $10^4\;CFU/mL$ (99.9%) and with a standard deviation of 0.21%, indicating that this fruit is the most suitable for developing a novel antimicrobial substance for inactivating B. subtilis spores.

Range Safety System Operation in KSR-III Flight Test (KSR-III 비행안전 시스템 운영)

  • Ko, Jeong-Hwan;Kim, Jeong-Rae;Park, Jeong-Joo;Bang, Hee-Jin;Choi, Dong-Min;Song, Sang-Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.91-97
    • /
    • 2004
  • The first Korean liquid propellant rocket KSR-III successfully finished its flight test on Nov. 28, 2002. Herein, we summarize the results of range safety system operation which is employed for the first time in flight tests of rockets developed by Korea Aerospace Research Institute(KARI). During the flight, safety-critical flight data including instantaneous impact points are monitored in realtime by range safety officers utilizing Range Safety Display Systems. The recorded screen of the display system is presented for the explanation of safety operation. In addition, comparisons are made between onboard navigation system based and radar based results in calculating instantaneous impact points, and also errors from the finally recorded impact point are described.

Blazed $GxL^{TM}$ Device for Laser Dream Theatre at the Aichi Expo 2005

  • Ito, Yasuyuki;Saruta, Kunihiko;Kasai, Hiroto;Nshida, Masato;Yamaguchi, Masanari;Yamashita, Keitaro;Taguchi, Ayumu;Oniki, Kazunao;Tamada, Hitoshi
    • Journal of Information Display
    • /
    • v.8 no.2
    • /
    • pp.10-14
    • /
    • 2007
  • A blazed $GxL^{TM}$ device is described as having high optical efficiency (> 70% for RGB lasers), and high contrast ratio (> 10,000:1), and that is highly reliable when used in a large-area laser projection system. It has a robust design and precise stress control technology to maintain a uniform shape (bow and tilt) of more than 6,000 ribbons, a $0.25-{\mu}m$ CMOS compatible fabrication processing and planarization techniques to reduce fluctuation of the ribbons, and a reliable Al-Cu reflective film that provided protection against a high-power laser. No degradation in characteristics of the GxL device is observed after operating a 5,000- lumen projector for 2,000 hours and conducting 2,000 temperature cycling tests at $-20^{\circ}C$ and $+80^{\circ}C$. At the 2005 World Exposition in Aichi, Japan the world's largest laser projection screen with a size of 2005 inches (10 m ${\times}$ 50 m) and 6 million pixels (1,080 ${\times}$ 5,760) was demonstrated.

Availability of Toxicologic Screening Tests in the Emergency Department (응급센터에서 시행하는 약물선별현장검사의 유용성)

  • Um, In-Kyung;Park, Jong-Su;Han, Kap-Su;Cho, Han-Jin;Choi, Sung-Hyuck;Lee, Sung-Woo;Hong, Yun-Sik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.1
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The role of a point of care test (POCT) is currently becoming important when treating patients and making decisions in the emergency department. It also plays a role for managing patients presenting with drug intoxication. But the availability of the test has not yet been studied in Korea. Therefore, we investigated the utility and the availability of POCT for drug screening used in the emergency department. Methods: This was a retrospective study for those patients with drug intoxication between January 2007 and December 2010 in an urban emergency department. Results: Between the study period, 543 patients were examined with a Triage$^{(R)}$-TOX Drug Screen. Among those, 248 (45.7%) patients showed negative results and 295 (54.3%) patients showed positive results. The sensitivity of the test for benzodiazepine, acetaminophen and tricyclic antidepressants were 85.9%, 100%, 79.2%, respectively. Conclusion: POCT of drug screening in emergency department showed good accuracy especially in patient with benzodiazepine, acetaminophen and tricyclic antidepressant intoxication. Therefore, it can be useful diagnostic tool for the management of intoxicated patients.

  • PDF

Laser Cladding with Al-36%Si Powder Paste on A319 Al Alloy Surface to Improve Wear Resistance (A319 알루미늄 합금 표면에 Al-36%Si 합금분말의 레이저 클래딩에 의한 내마모성 향상)

  • Lee, Hyoung-Keun
    • Journal of Welding and Joining
    • /
    • v.35 no.2
    • /
    • pp.58-62
    • /
    • 2017
  • A319 aluminum alloy containing 6.5% Si and 3.5% Cu as major alloying elements has been widely used in machinery parts because of its excellent castability and crack resistance. However it needs more wear resistance to extend its usage to the severe wear environments. It has been known that hyper-eutectic Al-Si alloy having more than 12.6% Si contains pro-eutectic Si particles, which give better wear resistance and lubrication characteristics than hypo-eutectic Al-Si alloy like A319 alloy. In this study, it was tried to clad hyper-eutectic Al-Si alloy on the surface of A319 alloy. In the experiments, Al-36%Si alloy powder was mixed with organic binder to make a fluidic paste. The paste was screen-printed on the A319 alloy surface, melted by pulsed Nd:YAG laser and alloyed with the A319 base alloy. As experimental parameters, the average laser power was changed to 111 W, 202 W and 280 W. With increasing the average laser power, the melting depth was changed to $142{\mu}m$, $205{\mu}m$ and $245{\mu}m$, and the dilution rate to 67.2 %, 72.4 % and 75.7 %, and the Si content in the cladding layer to 16.2 %, 14.6 % and 13.7 %, respectively. The cross-section of the cladding layer showed very fine eutectic microstructure even though it was hyper-eutectic Al-Si alloy. This seems to be due to the rapid solidification of the melted spot by single laser pulse. The average hardness for the three cladding layers was HV175, which was much higher than HV96 of A319 base alloy. From the block-on-roll wear tests, A319 alloy had a wear loss of 5.8 mg, but the three cladding layers had an average wear loss of 3.5 mg, which meant that an increase of 40 % in wear resistance was obtained by laser cladding.

A study on the identification of underwater propeller singing phenomenon (수중 프로펠러 명음 현상의 규명에 관한 연구)

  • Kim, Taehyung;Lee, Hyoungsuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.2
    • /
    • pp.92-98
    • /
    • 2018
  • This paper is a study on the generation mechanism of propeller singing based on the cavitation tunnel test, underwater impact test, finite element analysis and computational flow analysis for the model propeller. A wire screen mesh, a propeller and a rudder were installed to simulate ship stern flow, and occurrence and disappearance of propeller singing phenomenon were measured by hydrophone and accelerometer. The natural frequencies of propeller blades were predicted through finite element analysis and verified by contact and non-contact impact tests. The flow velocity and effective angle of attack for each section of the propeller blades were calculated using RANS (Reynolds Averaged Navier-Stokes) equation-based computational fluid analysis. Using the high resolution analysis based on detached eddy simulation, the vortex shedding frequency calculation was performed. The numerical predicted vortex shedding frequency was confirmed to be consistent with the singing frequency and blade natural frequency measured by the model test.

Study on the Sun Screen Test Method using Elipsometer (분광타원해석기를 이용한 자외선 차단제의 평가방법 연구)

  • Kim, Joon-Woo;Lee, Jong-Soo;Lee, Ji-Hye;Choung, Suk-Jin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.137-141
    • /
    • 2011
  • Sunscreen is divided into the organic agent of UV absorption and inorganic agent of reflection. These are evaluated by sun protection factor (SPF) in-vivo test requiring high cost and time, while in-vitro tests are adopted commonly because of short test time, easy result collection. Generally, test method of SPF use SPF 290a by UV-vis spectrometer. The evaluate by SPF 290 has low reproducibility. Although analysis using UV-vis spectrometer has high reproducibility, it is hard to separated results of transmission, adsorption, and reflection. In this study, suggested method of elipsometer has some merit such as high reproducibility, easy separation of transmission/adsorption/re- flection, analysis using various incident angle. We tested the validity of elipsometer for SPF measurement, using commercially available sun-block (SPF 50).