• Title/Summary/Keyword: scintillator

Search Result 282, Processing Time 0.024 seconds

Development and Characterization of a Dosimeter Using Tissue-Equivalent Scintillator by Photon-Counting Method (조직 등가 섬광체를 이용한 계수형 선량계의 개발과 특성 평가)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, Hong-Joo
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • A dosimeter using tissue-equivalent scintillator by photon-counting method was developed and evaluated in its performance. The dosimeter is portable and can be operated by low power from lap-top computer. A data-acquisition software of the dosimeter system was developed by Labwindows/CVI based on Windows. The energy to channel ratio for energy calibration was 0.839 keV/ch. obtained from pulse height spectrum of $^{137}Cs$ and $^{60}Co$ gamma-ray. Using the dosimeter system, the absorbed dose of environmental radiation in Gyungju was 0.18 ${\mu}Sv/h$.

Characteristics of Plastic Scintillators Fabricated by a Polymerization Reaction

  • Lee, Cheol Ho;Son, Jaebum;Kim, Tae-Hoon;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.592-597
    • /
    • 2017
  • Three plastic scintillators of 4.5 cm diameter and 2.5-cm length were fabricated for comparison with commercial plastic scintillators using polymerization of the styrene monomer 2.5-diphenyloxazole (PPO) and 1,4-bis benzene (POPOP). Their maximum emission wavelengths were determined at 426.06 nm, 426.06 nm, and 425.00 nm with a standard error of 0.2% using a Varian spectrophotometer (Agilent, Santa Clara, CA, USA). Compton edge spectra were measured using three gamma ray sources [i.e., cesium 137 ($^{137}Cs$), sodium 22 ($^{22}Na$), and cobalt 60 ($^{60}Co$)]. Energy was calibrated by analyzing the Compton edge spectra. The fabricated scintillators possessed more than 99.7% energy linearity. Light output was comparable to that of the BC-408 scintillator (Saint-Gobain, Paris, France). The fabricated scintillators showed a light output of approximately 59-64% of that of the BC-408 scintillator.

Pulse shape discrimination using a stilbene scintillator array coupled to a large-area SiPM array for hand-held dual particle imager applications

  • Jihwan Boo;Mark D. Hammig;Manhee Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.648-654
    • /
    • 2023
  • A dual-particle imager (DPI) is configured in a hand-held form factor, then one can efficiently and conveniently deploy the DPI to detect the presence of special nuclear materials (SNM) and identify any isotopic variations that differ from their natural abundances. Here we show that by maximizing the areal coupling between a pixelated scintillator array and the partitioned photosensor readout such as a silicon photomultiplier (SiPM), the information utilization of the gamma-ray and neutron information in the radiation field can be enhanced, thus enabling one to rapidly acquire spatial maps of the distributions on gamma-ray and neutron emitters.

Spectra Responsibility of Quantum Dot Doped Organic Liquid Scintillation Dosimeter for Radiation Therapy

  • Kim, Sung-woo;Cho, Byungchul;Cho, Sangeun;Im, Hyunsik;Hwang, Ui-jung;Lim, Young Kyoung;Cha, SeungNam;Jeong, Chiyoung;Song, Si Yeol;Lee, Sang-wook;Kwak, Jungwon
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.226-231
    • /
    • 2017
  • The aim is to investigate the spectra responsibilities of QD (Quantum Dot) for the innovation of new dosimetry application for therapeutic Megavoltage X-ray range. The unique electrical and optical properties of QD are expected to make it a good sensing material for dosimeter. This study shows the spectra responsibility of toluene based ZnCd QD and PPO (2.5-diphenyloxazol) mixed liquid scintillator. The QDs of 4 sizes corresponding to an emission wavelength (ZnCdSe/ZnS:$440{\pm}5nm$, ZnCdSeS:470, 500, $570{\pm}5nm$) were utilized. A liquid scintillator for control sample was made of toluene, PPO. The Composition of QD loaded scintillators are about 99 wt% Toluene as solvent, 1 wt% of PPO as primary scintillator and 0.05, 0.1, 0.2 and 0.4 wt% of QDs as solute. For the spectra responsibility of QD scintillation, they were irradiated for 30 second with 6 MV beam from a LINAC ($Infinity^{TM}$, Elekta). With the guidance of 1.0 mm core diameter optical fiber, scintillation spectrums were measured by a compact CCD spectrometer which could measure 200~1,000 nm wavelength range (CCS200, Thorlabs). We measured the spectra responsibilities of QD loaded organic liquid scintillators in two scintillation mechanisms. First was the direct transfer and second was using wave shifter. The emission peaks from the direct transfer were measured to be much smaller luminescent intensity than based on the wavelength shift from the PPO to QDs. The emission peak was shifted from PPO emission wavelength 380 nm to each emission wavelength of loaded QD. In both mechanisms, 500 nm QD loaded samples were observed to radiate in the highest luminescence intensity. We observed the spectra responsibility of QD doped toluene based liquid scintillator in order to innovate QD dosimetry applicator. The liquid scintillator loading 0.2 wt% of 500 nm emission wavelength QD has most superior responsibility at 6 MV photon beam. In this study we observed the spectra responsibilities for therapeutic X-ray range. It would be the first step of innovating new radiation dosimetric methods for radiation treatment.

Imaging Study of Fine Pixel Scintillator Block using Reflector on the Side of Light Guide (광가이드 측면 반사체 사용을 통한 미세 픽셀 섬광체 블록의 영상화 연구)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.671-677
    • /
    • 2023
  • When a scintillator block is constructed using fine scintillator pixels, the scintillator block located at the edge of the scintillator block results in overlapping images. To solve this problem, a light guide was inserted between the scintillator block and the photosensor, and images of all scintillation pixels were separated and acquired. However, loss of light may occur through the light guide, which eventually affects the quality of the image due to a decrease in energy resolution. Therefore, in this study, a detector was designed that can separate scintilltion pixels better by using a reflector on the side of the light guide and can secre excellent energy resolution by minimizing light loss. For comparative evaluation with previous studies, flood images were obtained through DETECT2000 capable of light simulation, and the degree of separation and light collection rate were evaluated. When a reflector was used on the side of the light guide, all materials showed excellent separation regardless of the material of the light guide, which showed better separation results than previous studies. In addition, the light collection rate was more that five times better when the reflector was applied than when it wa not. If this detector is applied to a small animal positron emission tomography, it will be possilbe to secre excellent image quality through excellent spatial resolution and energy resolution.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

Preparation of a thin film type of plastic scintillation detector for beta-ray detection (얇은 필름 형태의 베타선 측정용 플라스틱 섬광검출기 제조)

  • Seo, Bum-Kyoung;Kim, Gye-Hong;Woo, Zu-Hee;Oh, Won-Zin;Lee, Kune-Woo;Han, Myeong-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.495-499
    • /
    • 2005
  • Notwithstanding antipathies against radiation, radiations are extensively used in various fields with development of the radiation technology. In order to safely manage such radiation it is necessary for development of the radiation measurement materials. In this paper a thin film type of plastic scintillator using in the contamination measurement devices was prepared. The plastic organic scintillator was prepared by simple solvent methods. It was possible to prepare in easy way and in various forms. The polysulfone which has high transparency and solubility was chosen. As the radiation measurement scintillator, the optical properties and radiation detection abilities were estimated.