Characteristics of Plastic Scintillators Fabricated by a Polymerization Reaction  

Lee, Cheol Ho (Department of Nuclear Engineering, Hanyang University)
Son, Jaebum (Department of Nuclear Engineering, Hanyang University)
Kim, Tae-Hoon (Department of Nuclear Engineering, Hanyang University)
Kim, Yong Kyun (Department of Nuclear Engineering, Hanyang University)
Publication Information
Nuclear Engineering and Technology / v.49, no.3, 2017 , pp. 592-597 More about this Journal
Abstract
Three plastic scintillators of 4.5 cm diameter and 2.5-cm length were fabricated for comparison with commercial plastic scintillators using polymerization of the styrene monomer 2.5-diphenyloxazole (PPO) and 1,4-bis benzene (POPOP). Their maximum emission wavelengths were determined at 426.06 nm, 426.06 nm, and 425.00 nm with a standard error of 0.2% using a Varian spectrophotometer (Agilent, Santa Clara, CA, USA). Compton edge spectra were measured using three gamma ray sources [i.e., cesium 137 ($^{137}Cs$), sodium 22 ($^{22}Na$), and cobalt 60 ($^{60}Co$)]. Energy was calibrated by analyzing the Compton edge spectra. The fabricated scintillators possessed more than 99.7% energy linearity. Light output was comparable to that of the BC-408 scintillator (Saint-Gobain, Paris, France). The fabricated scintillators showed a light output of approximately 59-64% of that of the BC-408 scintillator.
Keywords
Compton Edge; Emission Wavelength; Light Output; Plastic Scintillator; Polymerization;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 H. Penttila, Characterization of a New Plastic Scintillation Material and Comparison with Liquid BC-501A Scintillator (Saint-Gobain, Paris, France), Oleksii Poleshchuk, Jyvaskyla, Finland, 2015.
2 D. Reilly, N. Ensslin, H. Smith Jr., S. Kreiner, Passive nondestructive assay of nuclear materials, in: Doug Reilly, Norbert Ensslin, Hastings Smith Jr. (Eds.), Los Alamos National Lab, Los Alamos, NM, USA, 1991.
3 Z. Li, W. Chong, H. Yuekun, Z. Xiaojian, S. Feng, Z. Sun, W. Jinjie, A. Henghua, Z. Yuda, Z. Ziping, W. Yifang, Properties of plastic scintillators after irradiation, Nucl. Instrum. Methods A 552 (2005) 449-455.   DOI
4 M. Bertolaccini, C. Bussolati, S. Cova, I. De Lotto, E. Gatti, Optimum processing for amplitude distribution evaluation of a sequence of randomly spaced pulses, Nucl. Instrum. Methods Phys. Res. A61 (1968) 84-88.
5 M. Moszynski, M. Kapusta, M. Mayhugh, D. Wolski, S.O. Flyckt, Absolute light output of scintillators, IEEE Trans. Nucl. Sci. 44 (1997) 1052-1061.   DOI
6 Organic Scintillation Materials, Saint-Gobain Crystals, Paris, France.
7 G.H. Kim, C.H. Park, C.H. Jung, K.W. Lee, B.K. Seo, Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes, J. Korean Assoc. Radiat. Prot. 31 (2006) 123-128.
8 B. Richard, Firestone Table of Isotopes, eigth ed., Wiley, New York, 1999.
9 Photomultiplier Tubes and Related Products, Hamamatsu Photonics Co., Hamamatsu City, Japan, 2010.