• Title/Summary/Keyword: school wastes

Search Result 201, Processing Time 0.028 seconds

A Study on Optimum Conditions Derivation on Thermal Hydrolysis of Food Wastewater and the Applicability of the Thermal Solubilization in Biological Denitrification Process (음폐수의 열가수분해 최적조건 도출과 생물학적 탈질공정에서 열가용화액의 적용 가능성에 관한 연구)

  • Lee, Ki Hee;You, Hee Gu;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.2
    • /
    • pp.151-158
    • /
    • 2015
  • The aim of this research is to derive an optimum operating condition for the thermal solubilization equipment that is employed to increase concentration of soluble organic materials and to assess whether it would be possible to use the waste sludge generated by thermal solubilization reaction as an external carbon source in biological denitrification process. For the purpose, we have constituted a laboratory-size thermal solubilization equipment and have assessed thermal hydrolysis efficiency based on various reaction temperature and reaction time. We have also derived SDNR using the waste sludge generated by thermal solubilization reaction through a batch experiment. As a result of research, the highest thermal hydrolysis efficiency of about 42.8% was achieved at $190^{\circ}C$ of reaction temperature and at 90 minutes of reaction time. And when SDNR was derived using the waste sludge, the value obtained was $0.080{\sim}0.094\;g\;NO_3{^-}-N/g\;MLVSS{\cdot}day$, showing SDNR that is higher than that obtained by the results of existing researches that used common wastewater as an external carbon source. Accordingly, in view of the fact that food wastes vary quite a bit in characteristics based on the area they are generated from and seasonal change, it seems that a flexible operation of thermal solubilization equipment is required through on-going monitoring of food wastes that are imported to food wastes recycling facilities.

Adolescents' Nutrient Intake Determined by Plate Waste at School Food Services (잔반 조사를 통한 중학생의 학교급식 영양섭취 실태 조사)

  • Lee Kyung-Eun
    • Korean Journal of Community Nutrition
    • /
    • v.10 no.4
    • /
    • pp.484-492
    • /
    • 2005
  • The purposes of the study were to analyze nutrients of the menus served and to evaluate students' nutrient consumption at school food services. Three middle schools (boys, girls, and co-ed schools) were located in Seoul and Kyunggi Province. A weighed plate method was employed to measure plate wastes and consumption of the menus served. Data was collected for 3 consecutive days at each school. Nutrient analyses for the served and consumed menus were performed using CAN-PRO. On average the students consumed $67\%$ of the menus they were served. By menu category, the students consumed more than $90\%$ of the rice and one-dish foods they were served. Kimchis ($54\%$) and soups/stews ($55\%$) were the menu categories with the lowest consumption rates. The menus served at the boys and coed schools did not meet 1/3 of the recommended daily allowances (RDA) for calcium, iron, and vitamin $B_2$. Due to the plate wastes, the actual consumption of the boys school students did not meet the 1/3 RDA for calories, calcium, iron, vitamin A, vitamin $B_1$ vitamin $B_2$ and niacin. The menus served at the girls school exceeded the 1/3 RDA for all nutrients, but the actual consumption did not meet the 1/3 RDA for calcium, iron, and vitamin $B_2$. During the 3-day periods, the served and consumed menus provided $27\%$ and $24\%$ of energy from fat, which exceeded the recommended proportion of $20\%$. To improve nutrition management at school food services, dietitians should understand factors that influence students' consumption and implement nutrition education programs that emphasize balanced diets.

GASIFICATION OF CARBONEOUS WASTES USING THE HIGH TEMPERATURE REFORMER

  • Lee, Dong-Jin
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.122-130
    • /
    • 2005
  • Gasification of carbonaceous wastes such as shredded tire, waste lubricating oil, plastics, and powdered coal initiates a single-stage reforming reactor(reformer) Without catalyst and a syngas burner. Syngas is combusted with $O_2$ gas in the syngas burner to produce $H_2O\;{and}\;CO_2$ gas with exothermic heat. Reaction products are introduced into the reforming reactor, reaction heat from syngas burner elevates the temperature of reactor above $1,200^{\circ}C$, and hydrogen gas fraction reaches 65% of the product gas output. Reactants and heat necessary for the reaction are provided through the syngas burner only. Neither $O_2$ gas nor steam is injected into the reforming reactor. Multiple syngas burners may be connected to the reforming reactor in order to increase the syngas output, and the product syngas is recycled into syngas burner.

A preparation plan proposal of nuclear power plant decommissioning radioactive waste characterization report (원자력발전소 해체 방사성폐기물 특성보고서 작성 방안 제안)

  • Kim, Chang Lak;Lee, Sun Kee;Kim, Heon;Park, Hae Soo;Sung, Suk Hyun;Kong, Chang Sig
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.76-84
    • /
    • 2021
  • Radioactive waste generated from nuclear power plant decommissioning shall be strictly managed so that radioactive materials above the allowable limit are not leaked into the environment. Radioactive wastes shall be classified and treated for management based on characteristics such as the type of waste, physicochemical properties, nuclide concentration and radioactivity. Waste characterization report shall be prepared and submitted to the disposal facility operator to ensure that the treated waste is suitable for disposal. The disposal facility operator shall review the waste Characterization report and visit the nuclear power plant decommissioning site to ensure that the wastes are processed step by step according to the plan. The waste Characterization report may be used as input data to evaluate disposal facility safety. Domestic and foreign data are collected and reviewed to confirm the entire processes from waste generation to delivery. This paper proposes the method to prepare the waste Characterization report which contains data and information on waste characteristics, treatment facilities & method and packaging method & container.

Application of waste tire rubber aggregate in porous concrete

  • Shariati, Mahdi;Heyrati, Arian;Zandi, Yousef;Laka, Hossein;Toghroli, Ali;Kianmehr, Peiman;Safa, Maryam;Salih, Musab N.A.;Poi-Ngian, Shek
    • Smart Structures and Systems
    • /
    • v.24 no.4
    • /
    • pp.553-566
    • /
    • 2019
  • This study aimed to categorize pervious rubberized concrete into fresh and hardened concrete analyzing its durability, permeability and strength. During the globalization of modern life, growing population and industry rate have signified a sustainable approach to all aspects of modern life. In recent years, pervious concrete (porous concrete) has significantly substituted for pavements due to its mechanical and environmental properties. On the other hand, scrap rubber tire has been also contributed with several disposal challenges. Considering the huge amount of annually tire wastes tossing out, the conditions become worse. Pervious concrete (PC) gap has graded surface assisted with storm water management, recharging groundwater sources and alleviate water run-offs. The results have shown that the use of waste tires as aggregate built into pervious concrete has tremendously reduced the scrap tire wastes enhancing environmental compliance.

Evaluation of Grade-Classification of Wood Waste in Korea by Characteristic Analysis (국내 폐목재 특성분석을 통한 등급화 평가)

  • Kim, Joung-Dae;Park, Joon-Seok;Do, In-Hwan;Hong, Soo-Youl;Oh, Gil-Jong;Chung, David;Yoon, Jung-In;Phae, Chae-Gun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1102-1110
    • /
    • 2008
  • This research was performed to analyze the characteristics of wood wastes from origin and to suggest grade-classification for them. Korean proximate analysis was conducted, and heating value, heavy metals and Cl concentrations were analyzed for gradeclassification. Wood wastes were sampled from forest, living, construction and demolition, and industrial areas with origin. Moisture content of most wood wastes was ranged in 5$\sim$10%. VS (volatile solids) and ash contents of them showed > 95% and < 5%, respectively. Most wood wastes except wood for growing mushroom permitted the standard (low heating value $\geq$ 3,500 kcal/kg) for refusederived fuel. CCA (Cr, Cu, As) concentration of wood wastes used in bench, wasted fishing boat, and railroad crosstie was higher than that of the other ones. Cl content showed approximately 1.3% in wood box for fish and $\leq$ 0.2% in the other wood wastes. Cl content of all wood wasted used in this research permitted the standard (Cl $\leq$ 0.2%, dry weight basis) for refuse-derived fuel. If the wood wastes were classified in 3-grade, plywoods would be in 2nd grade, and MDF (medium density fiber), wooden bench, painted electric wire drum, wasted fishing boat, and railroad crosstie be in 3rd grade.

A Study on the Recycling of Waste in the Limestone Mine (석탄석광산 폐석의 재활용 연구)

  • Chae, Young-Bae;Joeng, Soo-Bok;Koh, Won-Sik;Park, Je-Shin;Yang, Shi-Young
    • Resources Recycling
    • /
    • v.5 no.4
    • /
    • pp.25-31
    • /
    • 1996
  • The wastes ot l~mestone mines have been cause the extrar.ngance of the valuablz m e r a l s and destruction of the environment. Therefore, \\-c tied ta separation of calcite illid clay from the limestone mine wastes by rotntmg screen type separator made by ourselves in order to recyding such us a raw matcriala for cement maimfacture. CaO amtents in the separated coarse products increased from 37.36 wt% to 42+2 wt% at the condition ihat water content in wastes was lzss than 6wt%, the passing time of specimen in &amber was 15 semnds and the rotation speed was 6OLl qm. A process in order lo separate wastes effectively to having wide range aI part~dcs ize was cstablishcd and CaO contents of coarsc products through this process increased to 46.85 wt%. Tbis rcsult is insuEiicient to directly rcusing as a raw malerials for cement. However, it is supposed that coarse products would be able to be reuscd as a raw materials uf cement, if only it rs sclected dolomite in wastes, and really it may be possible in fields Othenvise, undcrsize products(less than 20 mm) would be able to recycling as a raw of cement bccause chcmicrl campasitions of thosc is kept almost constant v&cs on the overall process.

  • PDF

An Investigation for Air Pollutants Emitted from Small-Scale Incinerators in Highway Service Area (고속도로 휴게소의 소형소각로에서 배출되는 대기오염물질 조사)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Hong, Min-Sun;Choi, Join-In;Moon, Su-Ho;Kim, Soon-Tae;Kim, Seung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.539-546
    • /
    • 2002
  • The physicochemical properties of solid wastes generated from seven highway service areas, four branch offices, and one construction site were analyzed in concert with air pollutants including heavy metals emitted from near-by small-scale incinerators. The amount of solid wastes generated from highway areas has been increasing with recent increases in the number of highways and passengers. Twelve incinerators examined in this study generally had capacity smaller than 100 kg/hr, most of which were equipped with cyclone for dust removal. It was seen that the concentrations of the gas-phase air pollutants (e.g., SO$_2$, NO$_{x}$, HCl and H$_2$S) were above the acceptable emission standards except one or two sites. CO concentrations at all incinerators were also higher due to incomplete combustion. In addition, particulate matters showed concentration six times higher at their maximum. The results of heavy metal analysis showed that the concentrations of Cu, Cd, and Ni satisfied the emission standards. whereas Pb at one site and Zn at five sites exceeded the standards. Cr measurement results indicated that 9 of 12 incinerators had higher values than the standard; especially one branch office showed nine times higher than normal concentration. In order to satisfy more stringent emission standards in the near future, it is necessary to install air pollution control system and to develop an intensified management plan.n.

Dental Waste Management Practices at Dental Offices in Gyeongsangnam-do (경남지역 치과의원 의료폐기물 관리실태)

  • Kim, Hae-Jin;SaKong, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.332-339
    • /
    • 2012
  • Objectives: The purpose of this study was to prevent health problems and environmental contamination resulting from inappropriate management of dental wastes and to provide reference data for revision and supplementation of dental clinic waste management guidelines. Methods: From 640 total of dental clinics registered in 16 cities and counties in Gyeongsangnam-do, 100 (60 in Changwon (Masan, Changwon), 29 in Gimhae, and 11 in Jinju) were included in this study. From July 2010 to September 2010, investigators visited the 100 dental clinics and conducted survey interviews using a structured survey questionnaire regarding disposal methods for liquid wastes (suction pump, spittoon container waste, used liquid disinfectants, and X-ray developer), and disposal methods for solid waste (suction pump, spittoon container waste, and general medical waste). Results: All the 100 dental clinics were found to treat liquid waste from suction pumps and spittoon containers in the same manner as general waste water. Nineteen percent of the clinics treated solid waste that was not filtered through the filter of a suction pump as general waste. Fifty or more percent of the clinics treated solid waste in spittoon containers as general waste. Seventy percent of the clinics used disinfectant solution, although most of them treated used disinfectants in the same manner as general waste water. Some clinics treated used X-ray developer and X-ray fixer in the same manner as general waste water. In most of the clinics, used drapes were washed within the clinic. Conclusions: It was found that waste water and dental wastes at some dental clinics were treated in inappropriately. Thus, in conclusion, the development of guidelines regarding proper management of liquid and solid dental waste at dental clinics is required, and hygiene and environmental training for workers at dental clinics is necessary.

Hydrogen Production from Hyperthermophilic Archaebacteria Thermococcus onnurineus NA1 (초고온성 고세균 Thermococcus onnurineus NA1에 의한 수소생산)

  • Kim, Ok-Sun;Na, Jeong-Geol;Kim, Hae-Jin;Rhee, Young-Woo;Kim, Mi-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.5
    • /
    • pp.671-677
    • /
    • 2011
  • A hyperthermophilic archaeon, $Thermococcus$ $onnurineus$ NA1 was studied to investigate its fermentation characteristics using various carbon sources including formate, maltose and carbon monoxide during the anaerobic batch cultivation at $80^{\circ}C$. Formate was the best carbon source for cell growth and hydrogen production among others. In the batch culture on formate, it was found that the cell concentration increased exponentially by 12 hrs of culture, after which the cell growth and formate consumption was retarded. Hydrogen production was continued more than 24 hrs although the cell growth was ceased at 18 hrs. Hydrogen production rate was directly correlated with the cell growth and formate degradation up to 18 hrs, and the average hydrogen production yield was 1.05 mole-$H_2$/mole-formate. Cell growth and hydrogen production were optimized at the initial pH 6-7, while inhibited at the initial pH lower than 5 and higher than 9.