산란선함유율(散亂線含有率)에 관(關)한 연구(硏究) (A Study on the Scattered-ray Content in Transmitted-ray)

  • 김창균;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제6권1호
    • /
    • pp.81-84
    • /
    • 1983
  • Scattered-rays are produced from objects in x-ray diagnosis and the quality of x-ray image is influenced by presence of the scattered-ray. Therefore, constant ways and means to suppress and to eliminate the scattered-ray were devised. Authors made an experimental study on the scattered-ray content in transmitted-ray using acryl phantoms and obtained the results as follows: 1. The scattered-ray content in transmitted-ray is not influenced by filtration and tube voltage. 2. Irradiated field size and the thickness of object are a potent influence to scattered-ray content.

  • PDF

피사체(被射體)두께에 따른 선량분포(線量分布) (Dosimetry according to the Object Thickness)

  • 이상석;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.85-88
    • /
    • 1979
  • When X-radiation passes through the human body; some is transmitted some is truly absorbed, and some is scattered. In diagnostic radiography, scattered radiation can reach the film if no protective measures are taken. This scattered ray increased density which not necessary for image formation. We studied about absorbtion, scattered ray and the way of get rid of scatter ray according to the x-ray tube kilovoltage and obtained results as follow; 1. Absorbtion ray increased proportion to KVP. 2. Scattered ray increased at high KVP and thick object. 3. Secondary radiation of the primary increased at high KVP and thick object. 4. Remove .ate of scattered ray decreased at thick object and increase at low KVP make use of 6:1 grid ratio

  • PDF

엑스선 촬영실의 공간산란선 발생 인자에 관한 연구 (A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room)

  • 나수경;한상효
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.393-399
    • /
    • 2009
  • 본 연구에서는 전리함을 이용하여 엑스선 촬영실 내에서 공간산란선량을 측정하고 산란선의 발생원과 조사 조건에 대한 산란율 의존성을 조사하였다. 아크릴 팬톰의 산란선 발생 인자를 조사하기 위해 관전압(40~140 kV)과 조사면($10{\times}10\;cm^2$, $20{\times}20\;cm^2$, $35{\times}35\;cm^2$)에 대한 산란율 변화를 측정하였다. 조사면이 $35{\times}35\;cm^2$일 때 측방산란율은 3.11~4.5%로 측정되었다. 촬영실 내에서 팬톰, 콜리메이터, 엑스선관, 벽면에서 발생하는 산란선량의 영향을 측정하였는데 전체 관전압에 대해 팬톰의 산란선 발생률은 95.4% 이상이었으며 콜리메이터, 엑스선관, 벽면의 산란선 발생률은 각각 2.6%, 1.3%, 0.7% 이하로 나타났다. 관전압 100 kV, 40 mAs 조사 조건에서 촬영실 내 팬톰으로부터 1 m 거리에서 측정한 공간선량은 최대 2 mR 정도로 나타나 조사조건의 최적화 등의 산란선 경감조치가 필요할 것으로 생각된다.

  • PDF

Ir-192 $\gamma$선(線)의 금속(金屬)에 대(對)한 산란분포(散亂分布)에 관(關)한 연구(硏究) (A Study on Scattering Distribution in Metal of Ir-192 Gamma-Ray)

  • 주광태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제4권1호
    • /
    • pp.63-71
    • /
    • 1981
  • The metal-plates(Aluminium. Copper, Lead) of change the variation thickness have been penetrated by the collimated beam($450mm{\times}4mm{\phi}$) of Gamma-ray from $^{192}Ir$. Then, the scattered $\gamma$-ray dose in variable angle and the directly transmitted $\gamma$-ray dose were measured using the electrometer of ionization chamber. The results were summarized as follows: 1. Obtained the mass attenuation coefficients of $Al;0.0937cm^2g^{-1},\;Cu;0.0937cm^2g^{-1},\;pb;0.244cm^2g^{-1}$. 2. Total intensity of front scattered $\gamma$-ray follow the order of Al>Cu>pb. 3. The scattered $\gamma$-ray intensity with the lager angle of scattering was saturated after increase rapidly, and the scattering angle of the more larger was decreased. 4. The scattered $\gamma$-ray intensity through plates of aluminium or copper was saturated after increase with thicker scatterer, and the intensity was decreased at the more thicker. But the variation of scattered $\gamma$-ray dose in the lead plate made the fewest than Al and Cu. 5. The ratio of the scattered $\gamma$-ray dose and the directly transmitted $\gamma$-ray dose was saturated after increase with the thicker scatterer, and the scatterer of the more thicker was decreased. Degree of total intensity in these ratios was followed the order of Cu>Al>Pb.

  • PDF

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

두부(頭部) X선촬영시(線撮影時) 산란선(散亂線)과 화질(畵質)에 관(關)한 검토(檢討) (A Study on the Image Quality and the Scattered Ray content in the Skull Radiography)

  • 허준;김창균;강홍석;이선숙;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.15-19
    • /
    • 1985
  • The seattered-ray have a bad effect to the image of x-ray film. Therefore, to obtain the better x-ray image, the most important point is to eliminate the scattered-ray, come from the patient, and the easiest method to eliminate the scattered-ray is to use a proper grid for tube voltages. Authors made an experiment on the scattered-ray contents and the image quality in skull radiography, and obtained the results as follows; 1. The scattered-ray content in skull radiography was 83%, but it could be reduced to 35%-50% by using grid. 2. The image contrast was most increased when the using grid ratio was 8:1. 3. The image quality was not influenced by the scattered-ray contents between 32% and 45%.

  • PDF

X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography)

  • 박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권2호
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

수술실 내 C-arm 장치의 산란선 분포에 대한 연구 (The Study on Scattered Ray by C-arm in Operation Room)

  • 박성현;박주미;김현수
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2011
  • A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in $0^{\circ}$ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from $30^{\circ}$ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.

  • PDF

일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석 (Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination)

  • 정동경;박명환;서정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구 (Leakage and scattered radiation from hand-held dental x-ray unit)

  • 김은경
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF