• Title/Summary/Keyword: scanning system

Search Result 2,485, Processing Time 0.031 seconds

Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

  • Chung, Kwangzoo;Han, Younyih;Ahn, Sung Hwan;Kim, Jin Sung;Nonaka, Hideki
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.267-271
    • /
    • 2016
  • In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at Samsung Proton Therapy Center. Following a successful completion of the acceptance test, the commissioning process including the beam data measurement for treatment planning system has been conducted. Extended measurements have been conducted as a validation of the clinical performance of the nozzle and various quality assurance protocols have been prepared.

Cross Section Visualizing System Using 3D Scanning Data (3D 스캐닝 데이터를 이용한 단면 형상 가시화 시스템)

  • Lee, Byeong-Hoon;Park, Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1769-1774
    • /
    • 2003
  • Reverse Engineering has wasted high cost and much of time because there were few softwares for supporting post-process of 3D scanning efficiently. However today Reverse Engineering is attracted by various researchers on a count of its practical use and gradually improved quality. Accordingly, many industries induce the technology of Reverse Engineering. For keeping with this general trend, the algorithms of generating meshes from 3D scanning data and visualizing their cross section are suggested in this research. It is expected that output data from the algorithms can be used in inspecting errors between product designs and their final products, and in finding a way to improve quality by considering ideal model data.

  • PDF

Electronic Structures of Graphene on Ru(0001) : Scanning Tunneling Spectroscopy Study

  • Jang, Won-Jun;Jeon, Jeung-Hum;Yoon, Jong-Keon;Kahng, Se-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.307-307
    • /
    • 2011
  • Graphene is the hottest topic in condensed-matter physics due to its unusual electronic structures such as Dirac cones and massless linear dispersions. Graphene can be epitaxially grown on various metal surfaces with chemical vapor deposition processes. Such epitaxial graphene shows modified electronic structures caused by substrates. Here, local geometric and electronic structures of graphene grown on Ru(0001) will be presented. Scanning tunneling microscopy (STM) and spectroscopy (STS) was used to reveal energy dependent atomic level topography and position-dependent differential conductance spectra. Both topography and spectra show variations from three different locations in rippled structures caused by lattice mismatch between graphene and substrate. Based on the observed results, structural models for graphene on Ru(0001) system were considered.

  • PDF

Fabrication of Scanning Fixture for Flexible Panels (유연 판넬의 스캐닝 고정구 제작)

  • Yin, Jeong-Je
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4080-4086
    • /
    • 2010
  • In this study, a scanning fixture for flexible parts such as large automotive panels is developed. For the minimization of the weight deflection of a hood outer panel, the N-2-1 fixture principle for flexible parts is adopted in the fixture design. The designed fixture for a hood outer panel is fabricated using the Alufix system. The springback of the entire hood outer panel can be measured successfully by the laser scanning with the developed fixture, which verifies the usefulness of the proposed design method for the flexible panels.

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.

A Study on Scanning Attack Defense System (Scanning Attack 에 대한 방어기법 연구)

  • Ki-Hoon Kim;Seung-Joo Kim;Young-Chang Cheon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.11a
    • /
    • pp.1543-1545
    • /
    • 2008
  • Scanning 은 불특정 사용자가 특정 시스템 혹은 네트워크에 대해 Dos/DDos Attack 을 하기에 앞서 취약성이 존재할 수 있는 서비스나 호스트를 발견하기 위해 취해지는 선행 기술 중 하나이다. 본 논문에서는 기존에 알려진 대표적인 Port Scanning 기법들에 대해 알아보고 기존에 널리 사용되고 있는 탐지 및 방어 기법과 이러한 방식이 가질 수 있는 문제점에 대해서도 살펴본 후 이를 보완할 수 있는 기법을 논의하고자 한다.

Measurement of Joint-Orientation and Monitoring of Displacement in Tunnel using 3D Laser Scanning System (3차원 레이저 스캐닝 시스템을 이용한 불연속면의 방향성 측정과 터널 변위 모니터링)

  • Shon, Ho-Woong;Oh, Seok-Hoon;Kim, Young-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.1
    • /
    • pp.47-62
    • /
    • 2006
  • More than 70% of Korean Peninsula is consisted of mountains, so that lots of roads, rail-roads and tunnel,which play a pivotal role in the industry activity, are existed along the rock-slope and in the rock-mass. Thus,it is urgent that tegration of management system through the optimum survey and design of rock-slope excavation, proper stabilization method and database of rock-slope. However, conventional methods have shortcoming with the economy of survey time and human resources, and the overcome of difficulties of approach to the in-situ rock-slope. To overcome the limitation of conventional method, this paper proposed the development of remote measurement system using Terrestrial Laser Scanning System. The method using Terrestrial 3D Laser Scanning System, which can get 3D spatial information on the rock-slope and2)Dept. Geosystem Engineering, Kangwon National University, Korea tunnel, has an advantage of reduction of measurement time and the overcome of difficulties of approach to the in-situ rock-slope/dam/tunnel. In the case of rock-slope, through the analysis of 3D modeling of point-cloud by Terrestrial Laser Scanning System, orientation of discontinuity, roughness of joint surface, failure shape and volume were successively achieved. in the case of tunnel face, through reverse-engineering, monitoring of displacement was possible.

  • PDF

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

The Reflected Property Analysis of 3D Laser Scanning System as Object Surface Materials (대상물 표면물질에 따른 3차원 레이저스캐닝 시스템의 반사특성분석)

  • Um, Dae-Yong;Kim, Ji-Hye
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.3
    • /
    • pp.347-356
    • /
    • 2009
  • Recently many kind of industry request 3D Modeling and visualize for object. So application of 3D laser scanning system is improved for 3D modeling and survey. But although application of scanner is steady improved, there are variety of caution error is contained in the result. There is request high quality survey for it is restricted by when field. To analysis what is consider major factor of reflect ratio about surface specification as ratio and characteristics accidental error. So this research use 3D laer scanning system what is adopted method of laser measurement for improvement accuracy 3D scan data. As a result we can check reflect volume will be improve as specification of survey object if it has high reflect ratio. It able to improve accuracy how laser scan data is revised by reflect volume.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF