• 제목/요약/키워드: scanner

검색결과 2,045건 처리시간 0.035초

현장 진단 응용을 위한 모바일 초음파 스캐너 개발 (Development of a Mobile Ultrasound Scanner for Point-of-care Applications)

  • 조정;손학렬;김기덕;송재희;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.66-78
    • /
    • 2009
  • A mobile ultrasound scanner developed for use in point-of-care applications is introduced, which can not only provide ultrasound images but can also measure various bio-signals. The mobile ultrasound scanner is also designed to meet the demanding requirements for point-of-care diagnosis, such as battery-powered operation, portability in terms of size and weigh, and real-time wireless communications capability for remote diagnosis. To meet these requirements, an efficient beamforming method for high resolution imaging with a small number of active elements, a hardware efficient beamformer architecture, and echo processing algorithms with greatly reduced computational complexity have been developed. Experimental results show that the prototype mobile ultrasound scanner is fully functional and satisfies most of the design requirements.

Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

  • Yun, Dalsun;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen
    • 대한치과교정학회지
    • /
    • 제48권4호
    • /
    • pp.262-267
    • /
    • 2018
  • The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.

3차원 레이저 스캐너를 이용한 인쇄롤 가공에 관한 연구 (Study on Printing Roll Manufacturing by using 3 Dimensional Laser Scanner)

  • 강희신;노지환;손현기
    • 한국레이저가공학회지
    • /
    • 제16권4호
    • /
    • pp.17-23
    • /
    • 2013
  • The research for the development of roll-to-roll printing process is actively underway on behalf of the existing semiconductor process. The roll-to-roll printing system can make the electronic devices to low-cost mass production. This study is performed for developing the manufacturing technology of the printing roll used in the printing process of electronic devices. The indirect laser engraving technology is used to create printable roll and the printable roll is made out of the chrome coated roll after coating copper and polymer on the surface of steel roll, ablating the polymer on the surface of roll and etching the roll. The 3 dimensional laser scanner and roll rotating systems are constructed and the system control program is developed. We have used the fiber laser of 100 W grade, the 3 dimensional laser scanner and the 3 axes moving stage system with a rotating axis. We have found the optimal conditions by performing the laser patterning experiments and can make the minimum line width of $24{\mu}m$ by using the developed 3 dimensional laser scanner system.

  • PDF

단속형 가변적층쾌속조형공정을 이용한 3차원 스캔데이터로부터 3차원 시작품의 쾌속 제작 (Rapid Manufacturing of 3D Prototype from 3D scan data using VLM-ST)

  • 이상호;안동규;김효찬;양동열;박두섭;채희창
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.536-539
    • /
    • 2002
  • The reverse engineering (RE) technology can quickly generate 3D point cloud data of an object by capturing the surface of a model using a 3D scanner. In the rapid prototyping (RP) technology, prototypes are rapidly produced from 3D CAD models in a layer-by-layer additive basis. In this paper, a physical human head shape is duplicated using a new RP process, the Transfer-type Variable Lamination Manufacturing process using expandable polystyrene foam sheet (VLM-ST), after the point cloud data of a human head shape measured from 3D SNX scanner are converted to STL file. From the duplicated human head shape, it has been shown that the VLM-ST process in connection with the 3D scanner is a fast and efficient process in that shapes with free surface, such as the human head shape, can be duplicated with ease. Considering the measurement time and the shape duplication time, the use of 3D SNX scanner and the VLM-ST process is expected to reduce the lead-time fur the development of new products in comparison with the other existing RE-RP connected manufacturing systems.

  • PDF

상호 간섭이 최소화된 고속 원자현미경용 XY 스캐너 제작 (An XY scanner with minimized coupling motions for the high speed AFM)

  • 박종규;문원규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.653-656
    • /
    • 2005
  • This paper introduces design, fabrication and experiment process of a novel scanner for the high speed AFM(Atomic Force Microscope). A proper design modification is proposed through analyses on the dynamic characteristics of the existing linear motion stages using a dynamic analysis program, Recurdyn. Since the scanning speed of each direction is allowed to be different, the linear motion stage for the high-speed scanner of AFM can be so designed to have different resonance frequencies for the modes with one dominant displacement in the desired directions. One way to achieve this objective is to use one-direction flexure mechanism for each direction and to mount one stage for fast motion on the other stage for slow motion. This unsymmetrical configuration separates the frequencies of the two vibration modes with one dominant displacement in each desired direction, hence, the coupling between the motions in the two directions. In addition, a pair of actuators is used for each axis to decrease the cross talks in the two motions and gives a force large enough to actuate the slow motion stage, which carries the fast motion stage. After these design modifications, a novel scanner with scanning speed higher than 10 Hz can be achieved to realize undistorted images in the high speed AFM.

  • PDF

3차원 영상처리를 이용한 암반 사면의 절리 측정에 관한 연구 (Measurement of Rock Slope Joint using 3D Image Processing)

  • 이승호;황영철;심석래;정태영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.854-861
    • /
    • 2005
  • Studied accuracy and practical use possibility of joint measurement that using 3D laser scanner to rock slope. Measured joint of Rock slope and comparison applied 3 dimension laser scanner and clinometer. 3D laser scanning system preserves on computer calculating to 3 dimension coordinate scaning laser to object. and according to laser measurement method of interior, produce correct vector value from charge-coupled device(CCD) or laser reciver and telegram register and time measuring equipment. Create of object x, y, z point coordinates to 3 dimension space of computer. Such 3 dimension point datum (Point Clouds) forms relocate position informations that exist to practical space to computer space. Practical numerical values related between each other. Compared joint distribution and direction that measured by laser scanner and clinometer. By the result, Distribution of joint projected almost equally. Could get more joint datas by measurement of 3 dimension scanner than measured by clinometer. Therefore, There is effect that objectification of rock slope investigation data, shortening of investigation periods, investigation reduction of cost. could know that it is very effective method in joint measuring.

  • PDF

구강스캐너를 이용한 임플란트 보철물 제작 증례 (Implant prosthesis using intraoral scanner: Case Report)

  • 강병길;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.256-261
    • /
    • 2015
  • 임플란트 보철물의 경우 무엇보다도 보철물의 정확성이 중요하며 이러한 이유로 인해 인상채득의 정확성을 확인하는 과정이 필수적이다. 그러나 인상재 자체의 오차가 존재하며 모형을 제작하는 과정에서도 오차가 발생하게 된다. 이에 대한 대안으로 구강스캐너를 통한 보철물 제작을 생각해 볼 수 있으며, 최근 구강스캐너와 기존의 인상법 간의 정확성에 있어 통계적으로 유의할만할 차이가 없다는 많은 문헌들이 발표되었다. 따라서 intraoral scanner를 이용하여 기존에 방법에 비해 보다 편하고, 빠르며, 정확한 임플란트 보철물을 제작하는 일련의 과정을 보고하고자 한다.

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구 (Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner)

  • 김재홍;이정수;심정석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

DETERMINATION OF LONGISSIMUS MUSCLE AREA IN PIG WITH ULTRASONIC LINEAR ELECTRONIC SCANNER

  • Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권2호
    • /
    • pp.229-235
    • /
    • 1992
  • The usefulness of a portable linear electronic scanner. B-mode ultrasonic machine, was evaluated for estimating the longissimus muscle area from ultrasonic measurement of the muscle depth in 22 live pigs. The electronic scanner was easy to operate for muscle measurements in live pigs, which did not have to be held but were caged. The cross-sectional images of longissimus muscle and covering muscles and fat appeared on the monitor with grey scale in real time. It was easy to identify the ultrasonograms of fat and muscular tissues because the images differed in the degree of the grey scale. The longissimus muscle had less echogenic image than the other muscles. The boundary lines between first, second or third layers of backfat and the longissimus muscle were distinct on the ultrasonogram. The ultrasonic measurement at the shoulder was not acceptable because of the unstable measurements and the complex tissue structure. The repeatabilities for the measurements of longissimus muscle depth at one-half body length and last rib were acceptable. The simple correlation coefficients between ultrasonic estimates of the muscle depth in live pigs and the actual areas in the carcass, were 0.50 and 0.55 at the last rib and the one-half body length, respectively. Therefore, those positions were similarly suitable to measure. The method of electronic scanner for determining longissimus muscle area from the muscle depth was suitable for practical use in the field because of the simple and inexpensive technique.

차선 유실구간 측위를 위한 레이저 스캐너 기반 고정 장애물 탐지 알고리즘 개발 (Laser Scanner based Static Obstacle Detection Algorithm for Vehicle Localization on Lane Lost Section)

  • 서호태;박성렬;이경수
    • 자동차안전학회지
    • /
    • 제9권3호
    • /
    • pp.24-30
    • /
    • 2017
  • This paper presents the development of laser scanner based static obstacle detection algorithm for vehicle localization on lane lost section. On urban autonomous driving, vehicle localization is based on lane information, GPS and digital map is required to ensure. However, in actual urban roads, the lane data may not come in due to traffic jams, intersections, weather conditions, faint lanes and so on. For lane lost section, lane based localization is limited or impossible. The proposed algorithm is designed to determine the lane existence by using reliability of front vision data and can be utilized on lane lost section. For the localization, the laser scanner is used to distinguish the static object through estimation and fusion process based on the speed information on radar data. Then, the laser scanner data are clustered to determine if the object is a static obstacle such as a fence, pole, curb and traffic light. The road boundary is extracted and localization is performed to determine the location of the ego vehicle by comparing with digital map by detection algorithm. It is shown that the localization using the proposed algorithm can contribute effectively to safe autonomous driving.