DOI QR코드

DOI QR Code

Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

  • Yun, Dalsun (Department of Orthodontics, College of Dentistry, Gangneung-Wonju National University) ;
  • Choi, Dong-Soon (Department of Orthodontics, College of Dentistry, Gangneung-Wonju National University) ;
  • Jang, Insan (Department of Orthodontics, College of Dentistry, Gangneung-Wonju National University) ;
  • Cha, Bong-Kuen (Department of Orthodontics, College of Dentistry, Gangneung-Wonju National University)
  • Received : 2017.10.12
  • Accepted : 2018.02.07
  • Published : 2018.07.25

Abstract

The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.

Keywords

References

  1. Ghafari J, Baumrind S, Efstratiadis SS. Misinterpreting growth and treatment outcome from serial cephalographs. Clin Orthod Res 1998;1:102-6. https://doi.org/10.1111/ocr.1998.1.2.102
  2. Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ. Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 2003;124:101-5. https://doi.org/10.1016/S0889-5406(03)00152-5
  3. Cha BK, Choi JI, Jost-Brinkmann PG, Jeong YM. Applications of three-dimensionally scanned models in orthodontics. Int J Comput Dent 2007;10:41-52.
  4. Lim MY, Lim SH. Comparison of model analysis measurements among plaster model, laser scan digital model, and cone beam CT image. Korean J Orthod 2009;39:6-17. https://doi.org/10.4041/kjod.2009.39.1.6
  5. Cha BK, Lee JY, Jost-Brinkmann PG, Yoshida N. Analysis of tooth movement in extraction cases using three-dimensional reverse engineering technology. Eur J Orthod 2007;29:325-31. https://doi.org/10.1093/ejo/cjm019
  6. Jang I, Tanaka M, Koga Y, Iijima S, Yozgatian JH, Cha BK, et al. A novel method for the assessment of three-dimensional tooth movement during orthodontic treatment. Angle Orthod 2009;79:447-53. https://doi.org/10.2319/0003-3219(2009)079[0447:ANMFTA]2.0.CO;2
  7. Lee SJ, Jang SY, Chun YS, Lim WH. Three-dimensional analysis of tooth movement after intrusion of a supraerupted molar using a mini-implant with partial-fixed orthodontic appliances. Angle Orthod 2013;83:274-9. https://doi.org/10.2319/060912-480.1
  8. Ali D, Mohammed H, Koo SH, Kang KH, Kim SC. Three-dimensional evaluation of tooth movement in Class II malocclusions treated without extraction by orthodontic mini-implant anchorage. Korean J Orthod 2016;46:280-9. https://doi.org/10.4041/kjod.2016.46.5.280
  9. Cuperus AM, Harms MC, Rangel FA, Bronkhorst EM, Schols JG, Breuning KH. Dental models made with an intraoral scanner: a validation study. Am J Orthod Dentofacial Orthop 2012;142:308-13. https://doi.org/10.1016/j.ajodo.2012.03.031
  10. Anh JW, Park JM, Chun YS, Kim M, Kim M. A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction. Korean J Orthod 2016;46:3-12. https://doi.org/10.4041/kjod.2016.46.1.3
  11. Bonett DG. Sample size requirements for estimating intraclass correlations with desired precision. Stat Med 2002;21:1331-5. https://doi.org/10.1002/sim.1108

Cited by

  1. Analysis of the Morphological Characteristics of the Palatal Rugae for Three-Dimensional Superimposition of Digital Models in Korean Subjects vol.2018, pp.None, 2018, https://doi.org/10.1155/2018/3936918
  2. Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva vol.2020, pp.None, 2020, https://doi.org/10.1155/2020/2920804
  3. Assessment of techniques used for superimposition of maxillary and mandibular 3D surface models to evaluate tooth movement: a systematic review vol.42, pp.5, 2018, https://doi.org/10.1093/ejo/cjz075
  4. Scanning Accuracy of Bracket Features and Slot Base Angle in Different Bracket Materials by Four Intraoral Scanners: An In Vitro Study vol.14, pp.2, 2018, https://doi.org/10.3390/ma14020365
  5. Digital (R)Evolution: Open-Source Softwares for Orthodontics vol.11, pp.13, 2018, https://doi.org/10.3390/app11136033
  6. Three-dimensional assessment of two different canine retraction techniques: a randomized split-mouth clinical trial vol.22, pp.1, 2018, https://doi.org/10.1186/s40510-021-00374-4