• Title/Summary/Keyword: scan test

Search Result 863, Processing Time 0.022 seconds

Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene (FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형)

  • Yang, Sungmin;Choi, Hyo Won;Kang, Yun Koo;Lee, Jin-Sung;Namgoong, Mee Kyung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.20 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • A 22-month-old girl who had taken iron supplements due to iron deficiency anemia, presented bloody mucoid stool for one month. She had a bruise at the right periorbital area due to minor trauma and hepatosplenomegaly. Laboratory studies showed anemia, thrombocytopenia, elevated alkaline phosphatase (ALP), hypophosphatemia, decreased haptoglobin, hypocomplementemia, negative direct/indirect Coomb's test, normal vitamin D3 level and high PTHi. Wrist x-ray showed no signs of rickets. The abdominal ultrasound showed only accessory spleen. Tandem mass spectrometry was normal. During follow up, bloody stool regressed after seven days of withdrawal of iron supplement and cow milk, and the total CO2 level had been within 15-20 mEq/L with normal anion gap. NGS (next generation sequencing) panel test for evaluation of renal tubular acidosis showed negative results. After low dose steroid and vitamin D supplements under the impression of hypocomplementemic vasculitis, thrombocytopenia, C3/C4, decreased haptoglobin, and elevated ALP level became normal. At 57 months of age, laboratory findings showed elevated liver enzyme, ALP and gamma-glutamyl transferase again. And liver cirrhosis with splenomegaly and diffuse renal disease were reported with abdomen CT scan. Liver biopsy reported macro- and micronodular cirrhosis. Urine organic acid profile showed elevated succinylacetone level. Whole exome sequencing revealed novel compound heterozygous mutations (NM_00137.2:c.107T>C, NM_00137, 2:c.614T>C) in FAH gene and confirmed by Sanger sequencing. Consequently, the patient was diagnosed as chronic hereditary tyrosinemia type I. She started low phenylalanine/tyrosine diet and nitisinone treatment. Our case had presented symptoms very slowly, which is the first case of chronic tyrosinemia type I in South Korea.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Clinical Characteristics of Pulmonary Aspergilloma (폐국균종의 임상적 고찰)

  • Kang, Tae-Kyung;Kim, Chang-Ho;Park, Jae-Yong;Jung, Tae-Hoon;Sohn, Jeong-Ho;Lee, Jun-Ho;Han, Seong-Beom;Jeon, Young-Jun;Kim, Ki-Beom;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo;Shin, Hyeon-Soo;Lee, Sang-Chae;Kweon, Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1308-1317
    • /
    • 1997
  • Background : Pulmonary aspergillomas usually arise from colonization and proliferation of Aspergillus in preexisting cavitary lung disease of any cause. About 15% of patients with tuberculous pulmonary cavities were found to have aspergilloma. We analyzed the clinical features and course of 91 patients with pulmonary aspergilloma. Method : During the ten-year period from June 1986 to May 1996, 91 patients whose condition was diagnosed as pulmonary aspergilloma at 4 university hospitals in Taegu city were reviewed. All patients fulfilled one of the following criteria : 1) histologic evidence of aspergilloma within abnormal air space in tissue sections, or 2) a positive Aspergillus serum precipitin test with the radiologic finding of a fungus ball. The histological diagno-sis was established in 81 patients(89.0%) and clinical diagnosis in 10 patients(11.0%). Results : 1) The age range was 22 to 65 years, with an average of 45 years. A male and female ratio was 1.7 : 1 (57 men and 34 women). 2) Hemoptysis was far the most frequent symptom(89%), followed by cough, dyspnea, weakness, weight loss, fever, chest pain. 3) In all but 14 cases(15.4%) there had been associated conditions. Pulmonary tuberculosis was far the most frequent underlying condition found(74.7%), followed by bronchiectasis (6.6%), cavitary neoplasm(2.2%), pulmonary sequestration(1.1%). 4) The involved area was usually in the upper lobes; the right upper lobe was involved in 39(42.9%), the left upper lobe in 31(34.1%), the left lower lobe in 13(14.3%), the right lower lobe in 7(7.7%), and the right middle lobe in 1(1.1%). 5) On standard chest roent geno gram the classic "bell-like" image of a fungus ball was found in 62.6% of the subjects. On CT scan, 88.1% of the subjects in which they were done. 6) The surgical therapy was undertaken in 76 patients, and medical therapy in 15 patients, including 4 patients with intracavitary instillation of amphotericin B. 7) The surgical modality was lobectomy in 55 patients(72.4%), segmentectomy in 16 patients(21.1%), pneumonectomy in 4 patients(5.3%), wedge resection in 1 patient(1.3%). The mortality rate was 3.9% (3 patients) ; 2 patients died of sepsis and 1 died of hemoptysis. The postoperative complications were encountered in 6 patients (7.9%), including each one patient with respiratory failure, bleeding, bronchopleural fistula, empyema, and vocal cord paralysis. 8) In the follow-up cases, each 2 patients of 71 patients with surgical treatment and 10 patients with medical treatment had recurrent hemoptysis. Conclusion : During follow-up of the chronic pulmonary disease with abnormal air space, if the standard chest roentgenograms are insufficient to detect a fungus ball, computed tomographic scan and serum precipitin test are likely to aid the diagnosis of patients with suspected pulmonary aspergilloma. A reasonable recommendation for management of a patient with aspergilloma would be to reserve surgical resection for those patients who have had severe, recurrent hemoptysis. And a well controlled cooperative study to the medical treatment such as intracavitary antifungal therapy is further needed.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

Making Aids of Magnetic Resonacnce Image Susing 3D Printing Technology (3D 프린트를 활용한 자기공명영상검사 보조기구 제작)

  • Choi, Woo jeon;Ye, Soo young;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.403-409
    • /
    • 2016
  • MRI scan is a useful method in the diagnosis of musculoskeletal excellent contrast of the organization. Depending on the patient's musculoskeletal examinations state the type of aids provided the aid is used there is also challenging as well as the costs do not vary. This study was produced by the use of 3D printing technology, an MRI aids. Aids in the production process, then through 3D modeling and then convert stl files using (3D MAX.2014, Fusion360) slicing programs (Cubicreater 2.1ver., Cura 15.4ver) converted to G-code printed on the FDM scheme (Cubicon Style, output was MICRO MAKE). Output is, but in the FDM to evaluate the SNR on the MRI images were compared to the test is the case before use, and then to produce a Water Phantom case of a PLA, ABS, a TPU thickness 3mm, using aids before, It was evaluated in a clinical image after qualitatively. Obtaining an image of SNR Warter Phantom appeared to have been evaluated as T1 NON $123.778{\pm}28.492$, PLA $123.522{\pm}28.373$, ABS $124.461{\pm}25.716$, TPU $124.843{\pm}27.272$. T2 NON $127.421{\pm}26.949$, was rated as PLA $124.501{\pm}27.768$, ABS $128.663{\pm}26.549$, TPU $130.171{\pm}25.998$. The results did not show statistically significant differences. The use of assistive devices before and after images Clinical evaluation method palliative $3.20{\pm}0.88$, $3.95{\pm}0.76$ after using the aids used to aid improved the quality of the image. Production of the auxiliary mechanism using a future 3D printing is expected are thought to be used clinically, it can be an aid making safe and comfortable than the inspection of the patient is an alternative to improve the problems of the aids used in the conventional do.

Comparison of X-ray VCUG with RI VCUG for Diagnosing VUR in Children (소아의 방광 요관 역류 진단시 X-ray 배뇨성 방광 요도 조영술(X-ray VCUG)과 방사성 동위원소 배뇨성 방광 요도 조영술(RI VCUG)의 비교)

  • Hong Hyun-Soook;Choi Deuk-Lin;Kim Eun-Mi;Kim Sung-Jun
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.187-195
    • /
    • 1999
  • Purpose : VUR is state where urine regurge from bladder to ureter and kidney. It is shown in about 1/3 of urinary tract infection patients and it is classified as grade I to V. We compared results from RI VCUG(Radiisotope voiding cystourethrography) and X-ray VCUG which used in diagnosing VUR in children, to evaluate which is better in diagnosing VUR in children. Methods : 41 Patients(19 males, 21 females), who visited Pediatric department, Soonchunhyang university Hospital from peroid of 1991. January to 1998. July for recurrent urinary tract infection or abnormalities in ultrasonogams, were enrolled in the study. The age ranged from 9 months to 17 years and mean age was 5 1/2 years. Both RI VCUG and X-ray VCUG were done and follow-up test of urine culture, renal ultrasonogram and RI VCUG were done every month, every 3 month and every 6 month, respectively to observe the disappearance of VUR and evaluated the prognosis. Results : 24 patients had taken RI VCUG and 17(70.1%) patients showed positive result. 22 patients had taken X-ray VCUG and 9(40.1%) patients showed findings of VUR. 17 patients had taken both tests and 14 patients showed positive result in RI VCUG and 6 of these patients also showed reflux in X-ray VCUG. 3 patients who showed negative in RI VCUG, showed negative also in X-ray VCUG. For prognosis, resolution and scar formation was shown in 8 patients each. Persistent VUR was shown in 6 patients and 2 of these patients VUR was corrected by operation, 1 patient showed decreased renal function, and 1 patient was not follwed up. 8 of 9 patients who showed findings of VUR on DMSA scan formed a scar and 8 patients who showed no findings of VUR didn't form a scar. Urine culture was positive in 17 of 19 patients with VUR. Positive rate in urine culture was higher than that of patients with no VUR who showed positivity in 15 of 21 patients for urine culture. E. coli was most common organism and the period free of UTI was 14 months in VUR patients and it was shorter compared to patients without VUR which was 26 months. Conclusion : In diagnosing VUR in children, the positive rate was higher in RI VCUG than X-ray VCUG. Therefore, in early diagnosis when VUR is suspicious but not shown in X-ray VCUG, RI VCUG should be done and it will help to make accurate diagnosis.

  • PDF

Preservation of Pulmonary Function after Sleeve Lobectomy in Patients with Lung Cancer (Sleeve 폐엽절제술 후 폐기능 보존에 대한 연구)

  • Koh, Young-Min;Park, Sang-Joon;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.;Kim, Kwhan-Mien;Kim, Jhin-Gook;Shim, Young-Mog
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.35-41
    • /
    • 1999
  • Background: Sleeve lobectomy of the main bronchus has been proposed to spare lung tissue in patients who cannot tolerate pneumonectomy because of impaired lung function. The purpose of this study was to evaluate whether sleeve lobectomy can preserve lung function as expected from preoperative evaluation of lung function in patients with non-small cell lung cancer. Method: Between January 1995 and March 1998, 15 patients with non-small cell lung cancer who underwent sleeve resection were evaluated. Preoperative evaluations included spirometry and quantitative lung perfusion scan, from which predicted postoperative $FEV_1$ was calculated. At least 3 months after operation follow up spirometry and bronchoscopy were performed. Predicted FEVj was compared with measured postoperative $FEV_1$. Result: Fourteen men and one woman, with median age of 58 years, were reviewed. The diagnosis was squamous cell carcinoma in 13 patients and adenocarcinoma of lung in 2 patients. Our results showed a excellent preservation of pulmonary function after sleeve lobectomy. Correlation between the predicted (mean, $2180{\pm}570mL$) and measured $FEV_1$ (mean, $2293{\pm}499mL$) was good(r=0.67, P<0.05). Furthermore, patient with low $FEV_1$ (<2L) showed improved lung function after sleeve lobectomy. Conclusion: These findings indicated a complete recovery of the reimplanted lung lobes after sleeve lobectomy. Therefore, this technique could be safely used in lung cancer patients with impaired lung function.

  • PDF

Evaluation of Retro recon for SRS planning correction according to the error of recognize to coordinate (SRS의 좌표 인식 오류 시 Retro recon을 이용한 수정 방법에 관한 평가)

  • Moon, hyeon seok;Jeong, deok yang;Do, gyeong min;Lee, yeong cheol;Kim, sun myung;Kim, young bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.101-108
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate the Retro recon in SRS planning using BranLAB when stereotactic location error occurs by metal artifact. Materials and Methods : By CT simulator, image were acquired from head phantom(CIRS, PTW, USA). To observe stereotactic location recognizing and beam hardening, CT image were approved by SRS planning system(BrainLAB, Feldkirchen, Germany). In addition, we compared acquisition image(1.25mm slice thickness) and Retro recon image(using for 2.5 mm, 5mm slice thickness). To evaluate these three images quality, the test were performed by AAPM phantom study. In patient, it was verified stereotactic location error. Results : All the location recognizing error did not occur in scanned image of phantom. AAPM phantom scan images all showed the same trend. Contrast resolution and Spatial resolution are under 6.4 mm, 1.0 mm. In case of noise and uniformity, under 11, 5 of HU were measured. In patient, the stereotactic location error was not occurred at reconstructive image. Conclusion : For BrainLAB planning, using Retro recon were corrected stereotactic error at beam hardening. Retro recon may be the preferred modality for radiation treatment planning and approving image quality.

  • PDF