• 제목/요약/키워드: scaled model tunnel

검색결과 135건 처리시간 0.026초

스마트 무인기 풍동시험 (Wind Tunnel Testing for Smart Unmanned Aerial Vehicle)

  • 장진덕;최성욱;이장연
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2006
  • Wind tunnel testings to develope tilt-rotor Smart Unmanned Aerial Vehicle (SUAV) were intensively performed. Small wind tunnel was used to find and evaluate design parameters and to fix general layout of configuration. The application of large tunnel with 40% scaled model is to collect performance and stability related aerodynamic data. During large scale model test wind tunnel is used as a tool to compare Flaperon types, to improve lift characteristics by using different height vortex generators and to alleviate nacelle separated flow effects on the wing.

  • PDF

축소모형을 이용한 방음터널의 자연채광 성능평가에 관한 연구 (A Study on the Evaluation of the Daylighting Performance in the Sound Barrier Tunnel)

  • 김임곤;최정민;박창섭;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.35-43
    • /
    • 2005
  • This study aims to evaluate the natural lighting performance in the sound barrier tunnel. Therefore, to evaluate the daylighting performance, the combinations of 3 tunnel roof types which are flat-roof-type(type A), slope-roof-type(type B), arch-roof-type(type C) and 3 window types which are side-window-type(type 1), one-window-roof type(type 2), two-window-roof type(type 3) are evaluated by experimenting small scaled models. In this 9 cases of experiment, illuminance levels of each case are analyzed and evaluated. The conclusion of this study is that slope-roof-type(B) and arch-roof-type(C) is preferable to flat-roof-type(A) and one-window-roof-type(B) and two-window-roof-type(C) is preferable to side-window-type(A) for daylighting in the sound barrier tunnel.

축소모형실험 폭원으로서 도폭선의 폭력조절 (Detonating Cord as a Controllable Source for Scaled Model Blasting Test)

  • 양형식;김종관;최미진;최병희;류창하
    • 터널과지하공간
    • /
    • 제17권4호
    • /
    • pp.295-300
    • /
    • 2007
  • 도폭선의 길이를 조절하여 폭력이 조절되도록 축소모형 실험하는 방법을 제안하였으며 콘크리트 블록의 발파에 적용하여 타당성을 검토하였다. 제안된 방법은 폭원 조절이 가능하고 또 축소모형실험 방법으로서 타당한 것으로 판단된다. 또 폭발열을 이용하여 산정한 폭원 축소율은 상당한 근거가 있는 것으로 판단되었다.

Three-dimensional finite element analysis of urban rock tunnel under static loading condition: Effect of the rock weathering

  • Zaid, Mohammad
    • Geomechanics and Engineering
    • /
    • 제25권2호
    • /
    • pp.99-109
    • /
    • 2021
  • Tunnel provide faster, safer and convenient way of transportation for different objects. The region where it is construction and surrounding medium has significant influence on the overall stability and performance of tunnel. The present simulation has been carried out in order to understand the behaviour of rock tunnel under static loading condition. The present numerical model has been validated with the laboratory scaled model and field data of underground tunnels. Both lined and unlined tunnels have been considered in this paper. Finite element technique has been considered for the simulation of static loading effect on tunnel through Abaqus/Standard. The Mohr-Coulomb material model has been considered to simulate elastoplastic nonlinear behaviour of different rock types, i.e., Basalt, Granite and Quartzite. The four different stages of rock weathering are classified as fresh, slightly, moderately, and highly weathered in case of each rock type. Moreover, extremely weathered stage has been considered in case of Quartzite rock. It has been concluded that weathering of rock and overburden depth has great influence on the tunnel stability. However, by considering a particular weathering stage of rock for each rock type shows varying patterns of deformations in tunnel.

편토압 및 측압이 터널거동에 미치는 영향 (Influence of eccentric load and lateral earth pressure on the tunnel behavior)

  • 안현호;서병욱;김동현;민동호;이선복;이석원
    • 한국터널지하공간학회 논문집
    • /
    • 제9권3호
    • /
    • pp.219-228
    • /
    • 2007
  • 본 연구에서는 축소모형실험을 통하여 편토압 및 측압이 터널 거동에 미치는 영향을 연구하였다. 모형실험 결과의 타당성은 수치해석을 통하여 검토하였다. 터널에 작용하는 편토압을 감소시킬 수 있는 방안으로 편향 배치된 지보구조를 제안하고 이 방안의 적용성을 검토하였다. 실험 결과, 편향 배치된 지보구조를 적용함으로서 발생되는 변위가 전체적으로 줄어들었고, 초기 균열이 발생되는 하중도 증가되었다. 또한 터널의 안정성에 크게 문제가 되는 최대 편압 수직하중 역시 증가함을 알 수 있었다. 터널에 작용하는 측압의 영향을 검토한 결과, 측압계수의 변화에 따라 변위 발생 양상 및 균열 발생 양상이 매우 변화함을 알 수 있었다. 또한, 안정성 측면에서 취약점을 나타내는 부분도 변화함을 알 수 있었다.

  • PDF

전산유체역학을 이용한 풍력터빈 축소효과 수치해석 (Numerical Analysis of Wind Turbine Scale Effect by Using Computational Fluid Dynamics)

  • 박영민;장병희
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.28-36
    • /
    • 2006
  • Numerical analysis of wind turbine scale effect was performed by using commercial CFD code, Fluent. For the numerical analysis of wind turbine, the three dimensional Navier-Stokes solver with various turbulence models was tested. As a turbulence mode, the realizable k-e turbulence model was selected for the simulation of wind turbines. To validate the present method, performance of NREL (National Renewable Energy Laboratory) Phase VI wind turbine model was analyzed and compared with its wind tunnel test and blind test data. Using the present method, numerical simulations for various size of wind tunnel models were carried out and characteristics were analyzed in detail. For wind tunnel test model, the size of nacelle may not be scaled down precisely because of available motor. The effect of nacelle size was also computed and analyzed though CFD simulation. The present results showed the good correlations in pre-stall region but much to be improved in post-stall region. In 2006 and 2007, the performance and the scale effect of standard wind turbine model will be tested in KARI(Korea Aerospace Research Institute) LSWT(Low Speed Wind Tunnel) and the present results will be validated with the wind tunnel data.

  • PDF

대형 풍력터빈 모형의 공력 성능 및 후류 유동장에 대한 비교 연구 (Comparison Study on Aerodynamic Performance and Wake Flow Field for a MW-Class Wind Turbine Model)

  • 정두원;원영수;강승희
    • 한국가시화정보학회지
    • /
    • 제17권2호
    • /
    • pp.32-38
    • /
    • 2019
  • A comparison study between computational-fluid-dynamics simulation and wind tunnel test for a megawatt-class wind turbine is conducted. For the study, flow-field in wake, basic aerodynamic performance, and effect of the yaw error for a 1/86 scaled-down model of the NREL offshore 5 MW wind turbine are numerically calculated using commercial software "FloEFD" with $k-{\varepsilon}$ turbulence model. The computed results are compared to the wind tunnel test performed by the constant-velocity mode for the model. It is shown that discrepancy are found between the two results at lower tip-speed ratio and higher yaw angle, however, the velocity-defection distribution in the wake, the torque coefficient at moderated and high tip-speed ratios are in good agreement with the wind tunnel test.

일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험 (The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster)

  • 유영일;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF

돌풍하중완화 풍동시험을 위한 돌풍발생장치 설계 및 지상시험 (Design and Ground Test of Gust Generator for GLA Wind Tunnel Test)

  • 이상욱;김태욱;김성찬;황인희;하철근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.45-48
    • /
    • 2005
  • Tile gust generator was designed for generating the gust field in the wind tunnel test of the scaled flexible wing model for validating gust response alleviation system. The ground operation test was performed for estimating the dynamic performance of tile gust generator before installing it in the wind tunnel for gust field measurement. The ground test results showed that the gust generator has sufficient dynamic capability to simulate the sinusoidal and random motion of the gust generator wing and thus can be used in the wind tunnel test related to gust.

  • PDF

쌍굴터널 간 이격거리가 터널 안정성에 미치는 영향에 관한 모형실험 연구 (Influence of Pillar Width on the Stability of Twin Tunnels Using Scaled Model Tests)

  • 김종우
    • 터널과지하공간
    • /
    • 제25권5호
    • /
    • pp.423-434
    • /
    • 2015
  • 본 연구에서는 필러 폭과 모형재료의 강도가 서로 다른 등방성 및 이방성 암반 내 쌍굴터널의 모형실험을 통해 얻어진 터널의 변형과 필러부 균열이 발생한 이축압력 자료를 이용하여 터널 간 이격거리, 지반 강도, 등방성 및 이방성이 터널 안정성에 미치는 영향을 알아보았다. 모형재료의 일축압축강도에 대한 균열개시압력의 백분율을 균열개시압력비율이라고 정의할 경우, 강도가 큰 지반에 시공되는 쌍굴터널은 강도가 작은 지반에 비하여 균열개시압력 값은 크지만, 균열개시압력비율은 작게 나타났다. 이에 비해 필러 폭이 큰 쌍굴터널은 필러 폭이 작은 경우에 비하여 균열개시압력 값이 클 뿐 아니라 균열개시압력비율도 크게 나타나, 필러 폭은 쌍굴터널 안정성에 영향을 미치는 주된 요소로 판단된다. 지반의 등방성과 이방성 여부도 터널 안정성에 영향을 미쳤는데, 이방성 모형은 등방성 모형에 비해 균열개시압력과 균열개시압력비율이 작을 뿐 아니라 필러부에 존재한 기존 불연속면을 따라 균열이 발생하였다.