• 제목/요약/키워드: saturation function

검색결과 394건 처리시간 0.03초

Anesthetic Effect of Different Ratio of Ketamine and Propofol in Dogs

  • Lee, Mokhyeon;Kim, Sohee;Moon, Chawnghwan;Park, Jiyoung;Lee, Haebeom;Jeong, Seong Mok
    • 한국임상수의학회지
    • /
    • 제34권4호
    • /
    • pp.234-240
    • /
    • 2017
  • Use of ketamine and propofol combination (so-called Ketofol) anesthesiain a fixed ratio (1:1 mg/ml) was reported in dogs. The use of ketofol reduced cardiovascular suppression, but respiratory-related side effects was not significantly different from propofol alone. In this study, we evaluated the quality of ketofol anesthesia and changes in cardiopulmonary function according to the ratio of ketamine to propofol. The experimental groups were divided into three groups: propofol alone (P group), 3:7 ketofol group (PK1 group) and 1:1 ketofol group (PK2). For each group, the dose of 0.8 ml/kgwas administered intravenously at a constant rate until the tracheal intubation was possible and anesthesia was maintained with isoflurane for 120 minutes after induction of anesthesia. There was no significant difference in the anesthetic quality among three groups. Also, there was no difference in respiratory rate, tidal volume, end-tidal carbondioxide, and oxygen saturation. In group P, heart rate was not changed significantly during anesthesia, but arterial blood pressure decreased, while heart rate and arterial blood pressure increased significantly in group PK2. In the PK1 group, heart rate and arterial blood pressure during anesthesia remained similar to pre-anesthetic values. In conclusion, ketofol might be used as induction agent, and 3:7 ratioof ketofol showed more safe and effective anesthetic effect in dogs. Additionally, 1:1 ketofol may be used in patients with severe bradycardia orhypotension with close monitoring during anesthesia.

YIG, Bi:YIG, TbBi:YIG 단결정 후막의 성장과 특성 (Growth and Characteristics of YIG, Bi:YIG, TbBi:YIG Single Crystal Thick Films)

  • 윤석규;김근영;김명진;이형만;김회경;윤대호
    • 한국세라믹학회지
    • /
    • 제40권7호
    • /
    • pp.672-676
    • /
    • 2003
  • Y$_3$Fe$_{5}$O$_{12}$(YIG), $Y_3$Fe$_{5}$O$_{12}$(Bi:YIG), TbBi:YIG를 (GdCa)$_3$(GaMgZr)$_{5}$O$_{12}$ (SGGG)기판 위에 Liquid Phase Epitaxy (LPE)법으로 단결정 후막을 성장시켰다. 기판회전속도, 과냉도, 성장시간을 고정하여 치환되는 원소의 종류와 양에 따라 가네트 단결정의 격자상수, Bi 치환양, 표면형상, 자기적 특성을 조사하였다. TbBi:YIG 조성의 경우 격자상수는 12.500 $\AA$으로 기판의 격자상수인 12.496 $\AA$에 근접하게 나타났으며, 포화자계는 150 Oe로 향상된 결과가 나타났다.

$Bi_2O_3{\cdot}3TiO_2$의 첨가량에 따른 $(SrPb)(CaMg)TiO_3$ 세라믹의 전기적 특성 (The Electrical Properties of $(SrPb)(CaMg)TiO_3$ Ceramics with Contents of $Bi_2O_3{\cdot}3TiO_2$)

  • 김충혁
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.111-120
    • /
    • 1998
  • In this paper, the $(SrPb)(CaMg)TiO_3$ ceramics with paraelectric properties were fabricated by the mixed oxide method. It was investigated that which the variation of contents of $Bi_2O_3{\cdot}3TiO_2$ effects on structural, dielectrical and electrical properties of specimens. As a result, the grain size were grown with increasing the contents of $Bi_2O_3{\cdot}3TiO_2$. The relative dielectric constants were increased up to 4[mol%] of $Bi_2O_3{\cdot}3TiO_2$, and decreased more or less at a low temperature in the specimens which had more than. But the temperature coefficient. of capacitance were showed ${\pm}25$[%]. The dielectric loss were less than 0.05 in all specimens which had more than 4[mol%] of $Bi_2O_3{\cdot}3TiO_2$. In order to investigate the behavior of charged particles, the characteristics of electrical conduction were measured. As a result, the conduction current was divided into the three steps as a function of DC electric field. The first step was Ohmic region due to ionic conduction, below 15[kV/cm]. The second step was showed a saturation which seems to be related to a depolarizing field occuring in field-enforced ferroelectric phase, between 15[kV/cm] and 40[kV/cm]. The third step was attributed to Child's law related to space charge which injected from electrode, above 40[kV/cm].

  • PDF

$(1-x)(SrPb)(CaMg)TiO_3-xBi_2O_3{\cdot}3TiO_2$ 세라믹의 하전입자 거동에 관한 연구 (A Study on the Behavior of Charged Particles of $(1-x)(SrPb)(CaMg)TiO_3-Bi_2O_3{\cdot}3TiO_2$ Ceramics)

  • 김충혁;최운식;정일형;정규희;이준응
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 추계학술대회 논문집
    • /
    • pp.34-37
    • /
    • 1992
  • In this paper, the $(SrPb)(CaMg)TiO_3$-xBi_2O_3{\cdot}3TiO_2$ ceramics with paraelectric properties were fabricated by the mixed oxide method. In order to investigate the behavior of charged particles, the characteristics of electrical conduction and thermally stimulated current were measured respectively. As a result on characteristics of the electrical conduction, the leakage current was increased as measuring temperature was increased. At room temperature, the conduction current was divided into the three steps as a function of DC electric field. The first step was Ohmic region due to ionic conduction, below 15[kV/cm]. The second step was showed a saturation which seems to be related to a depolarizing field occuring in field-enforced ferroelectric phase, between 15[kV/cm] and 40[kV/cm]. The third step was attributed to Child's law related to spare charge which injected from electrode, above 40[kV/cm]. Thermally stimulated currents(TSC) spectra with various biasing fields exhibited three distinguished peaks that were denoted as ${\alpha}$, ${\alpha}'$ and ${\beta}$ peak, each of which appeared at nearby -30, 20 and 95[$^{\circ}C$] respectively. It is confirmed that the a peak was due to trap electron trapped in the grainboundary, and ${\alpha}'$ peak that was observed above only 1.5[kV/mm] was attributed to field-enforced ferroelectric polarization. The origin of ${\beta}$ peak was identified as ion migration which caused the degradation.

  • PDF

수평원관 내 CO2 R-22 및 R-134a의 증발열전달 특성에 관한 실험적 연구 (Evaporation Heat Transfer Characteristics of CO2 R-22 and R-134a in a Horizontal Smooth Tube)

  • 윤린;황준현;최영돈;김용찬
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.911-918
    • /
    • 2002
  • Evaporation heat transfer coefficients of carbon dioxide($CO_2$), R-22, and R-134a in a horizontal smooth tube were measured and analyzed as a function of heat flux, mass flux, and evaporating temperature. The experiments were carried out by varying heat flux from 10 to 20 $kW/m^2$, mass flux from 170 to 340 $kg/m^2s$, and saturation temperatures of 5 and $10^{\circ}C$. It was found that the heat transfer coefficient of $CO_2$ decreased with a rise of quality due to an earlier liquid-film dryout as compared to R-22 and R-134a. Averaged heat transfer coefficients of $CO_2$ were 22-63% higher than those of R-22 and R-134a at all test conditions. The effects of mass flux and heat flux on averaged heat transfer coefficients were much greater in $CO_2$ than in R-22 and R-134a. When comparing $CO_2$ test results with the correlations in the literature, the existing models yielded large deviations at medium and high qualities. Therefore, a generalized correlation for $CO_2$evaporation heat transfer needs to be developed by including the effects of dryout phenomenon.

IEEE 802.11ac/ad 무선 LAN의 적응형 MCS 구현 연구 (Implementation of Adaptive MCS in The IEEE 802.11ac/ad Wireless LAN)

  • 이하철
    • 한국통신학회논문지
    • /
    • 제40권8호
    • /
    • pp.1613-1621
    • /
    • 2015
  • 본 연구에서는 초고속 WLAN(Wireless LAN)인 IEEE 802.11ac 및 802.11ad 에서 처리율 향상을 위한 전송율 제어기법과 이에 따른 MCS(Modulation and Coding Scheme)의 적용방안을 제시한다. IEEE 802.11ac 및 802.11ad 표준은 기존의 IEEE 802.11b/g/a 무선 LAN표준과는 달리 송신측이 시간적으로 변하는 채널조건에 따라 전송율을 제어하여 처리율을 높일 수 있도록 하기 위해 많은 MCS 기능을 지원한다. 그러나 이들 표준에서는 전송율을 제어할 수 있는 알고리듬을 제시하고 있지 않으므로 본 연구에서는 전송율 제어 알고리듬에 대하여 살펴보고 MCS의 적용 방안을 제시한다. 특히 IEEE 802.11ac 무선 LAN의 DCF 처리율 성능을 에러를 갖는 채널 환경하에서 분석하기 위해 A-MPDU 기법이 활용되었고 패킷 에러율, 단말장치의 수, 프레임의 수, 프레임 페이로드 크기 및 전송 확률이 변수로 사용되었다.

Automatic $St{\ddot{o}}ckigt$ Sizing Test Using Hue Value Variation of a Droplet

  • Kim, Jae-Ok;Kim, Chul-Hwan;Lee, Young-Min;Kim, Gyeong-Yun;Shin, Tae-Gi;Park, Chong-Yawl
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.227-230
    • /
    • 2006
  • The $St{\ddot{o}}ckigt$ sizing test of the most-commonly used sizing tests is easily influenced by the individual testers' bias in recognizing red coloration. Therefore the test had to be modified to improve its reliability and reproducibility by automated recognition of a coloration procedure during testing. In order to achieve this, all measured variables occurring during the $St{\ddot{o}}ckigt$ test was first be analyzed and then reflected in the new automatic system. Secondly, the most important principle applied was to transform the RGB values of the droplet image to hue (H), saturation (S) and value (V) respectively. This is because RGB cannot be used as a color standard, owing to RGB's peculiarity of being seriously affected by the observer's point of view. Therefore, the droplet color had to be separated into three distinct factors, namely the HSV values, in order to allow linear analysis of the droplet color. When the average values of the vectors calculated during color variation from yellow to brown were plotted against time, it was possible to determine the vector value of hue, the most sensitive factor among HSV, at the specific time by differentiation of a function when it exceeds the critical point. Then, the specific time consumed up to the critical point was regarded as the $St{\ddot{o}}ckigt$ sizing degree. The conventional method took more time to recognize an ending point of coloration than the automatic method, and in addition the error ranges of the conventional sizing degrees on the specific addition points of AKD were wider than those of the automatic method.

  • PDF

한강의 수질지수 산정에 관한 연구 (A Study on Evaluation for the Han River Water Quality Index)

  • 서정현
    • 물과 미래
    • /
    • 제14권3호
    • /
    • pp.55-66
    • /
    • 1981
  • The theory and practice of water quality scoring and indexing are introduced. The monthly water analysis data are available for six stations long the down-stream Han River whthin the areal boundary of the Special City of Seoul. The data cover the period between 1975 and 1979 inclusive and contain the analytical findings on 37 water constituents including DO, BOD, temperature, total solids and etc. Sic parameters are selected form the 37 items, that, to the judgement of the writer, best reflect the water quality of the Han River. They are; dissolved oxggen saturation, pH, fecal coliform, total solids, BOD and nitrate+ammonia. For each of the six parameters, a subscore function is developed and graphically presented to facilitate the transform of a measurment of the arameter to a subscore on a common score(e.G. 0-100) The score of a sample is calculated as a fuction of the six subscores, using four different approaches; (1) the unweighted arithmetic water quality score, (2) the weighted arithmetic water quality score, (3)the unweighted multiplicative score and (4) the reduced (total) score. Independent of these calculated scores, the experts' score which is calculated by averaging the ratings of water quality experts is obtained and compared with each of the four calculated scores by means of the least square method. The experts' score compares most favorably with the "reduced" score with the correlation coefficient of 0.956 : therefore this method of water quality scoring is adopted to calculate the Han River water quality scores and indices. Water quality index data for Guiri, ukdo, Pokwangdong, Noryangjin, Yongdungpo and Kayang Stations, 1975-1979 are as follow: The overall water quality index data of the Han River between Guiri and Kayang Stations are found; 47.3 in 1976, 48.0 in 1977, 48.5 in 1978 and 54.7 in 1979, indicating the general trend towards water quality improvent in this part of the river, in terms of the increased water quality index by average 1.85 points per year during this period. Finally the optimum sampling frequencies distributed among the six stations, using an equation which takes into account the coefficients of variation of the water quality scores and indices arec calculated.alculated.

  • PDF

In-situ magnetization measurements and ex-situ morphological analysis of electrodeposited cobalt onto chemical vapor deposition graphene/SiO2/Si

  • Franco, Vinicius C. De;Castro, Gustavo M.B.;Corredor, Jeaneth;Mendes, Daniel;Schmidt, Joao E.
    • Carbon letters
    • /
    • 제21권
    • /
    • pp.16-22
    • /
    • 2017
  • Cobalt was electrodeposited onto chemical vapor deposition (CVD) graphene/Si/$SiO_2$ substrates, during different time intervals, using an electrolyte solution containing a low concentration of cobalt sulfate. The intention was to investigate the details of the deposition process (and the dissolution process) and the resulting magnetic properties of the Co deposits on graphene. During and after electrodeposition, in-situ magnetic measurements were performed using an (AGFM). These were followed by ex situ morphological analysis of the samples with ${\Delta}t_{DEP}$ 30 and 100 s by atomic force microscopy in the non-contact mode on pristine CVD graphene/$SiO_2$/Si. We demonstrate that it is possible to electrodeposit Co onto graphene, and that in-situ magnetic measurements can also help in understanding details of the deposition process itself. The results show that the Co deposits are ferromagnetic with decreasing coercivity ($H_C$) and demonstrate increasing magnetization on saturation ($M_{SAT}$) and electric signal proportional to remanence ($M_r$), as a function of the amount of the electrodeposited Co. It was also found that, after the end of the dissolution process, a certain amount of cobalt remains on the graphene in oxide form (this was confirmed by X-ray photoelectron spectroscopy), as suggested by the magnetic measurements. This oxide tends to exhibit a limited asymptotic amount when cycling through the deposition/dissolution process for increasing deposition times, possibly indicating that the oxidation process is similar to the graphene surface chemistry.

High-Level Expression and Characterization of Single Chain Urokinase-type Plasminogen Activator(scu-PA) Produced in Recombinant Chinese Hamster Ovary(CHO) Cells

  • Kim, Jung-Seob;Min, Mi-Kyung;Jo, Eui-Cheol
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제6권2호
    • /
    • pp.117-127
    • /
    • 2001
  • The high-level expression of a human single chain urokinase-type plasminogen activator (scu-PA) was achieved by employing a methotrexate (MTX)-dependent gene amplification system in Chinese hamster ovary (CHO) cells. By cotransfecting and coamplifying a scu-PA expression plasmid and dihydrofolate reductase (DHFR) minigene, several scu-PA expressing CHO cell lines were selected and gene-amplified. These recombinant cell lines, NGpUKs, secreted a completely processed scu-PA of 54 kD and up to 60mg/L was accumulated in the culture medium when they were adapted to an optimal MTX concentration. Over 95% of the scu-PA expressed was secreted in the culture medium and identified having the proper function of a plasminogen activator when activated by plasmin. Based on a genomic Southern analysis, a representative subclone, MGpUK-5, exhibited MTX-dependent scu-PA gene amplification, plus the initial single-copy gene of scu-PA eventually turned into about 150 copies of the amplified gene of scu-PA after gradual adaptation to 2.0$\mu$M of MTX. Meanwhile, the transcripts kof the scu-PA gene increased, although -early saturation of transcription was identified at 0.1$\mu$M of MTX. The scu-PA production by the MGpUK-5 subclone also increased relative to the gene amplification and increased transcripts, however, the relationship was not linearly proportional. Accordingly, since the MGpUK cell lines expressed elevated levels of enzymatically active scu-PA, these cell lines could be applied to the largescale production of scu-PA.

  • PDF