• Title/Summary/Keyword: saturated concrete

Search Result 84, Processing Time 0.035 seconds

Drying Shrinkage and Strength Properties of Polymer-Modified Mortars Using Redispersible Polymer Powder (재유화형 폴리머 분말수지 혼입 폴리머-시멘트 모르타르의 건조수축 및 강도특성)

  • Yeon, Kyu-Seok;Joo, Myung-Ki;Jeong, Jung-Ho;Jin, Xing-Qi;Lee, Chi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.533-536
    • /
    • 2005
  • Drying shrinkage and strength of the redispersible SBR and PAE powder-modified mortars were experimentally investigated. Results of the study that the drying shrinkage rapidly increased until 7 days of age and it was then saturated to the value of about $1\~2\times10^{4}$ after 14 days. It turned out that the polymer-cement ratio exerted more influence on the drying shrinkage than the content of powder shrinkage-reducing agent did. Flexural (compressive) strength of the mortar increased (decreased) as the polymer-cement ratio increased and it was 7$\~$11 (23$\~$39) MPa at 7 days of age. The average (maximum) increasing (decreasing) rate turned out to be about 10 (30) $\%$. As in the drying shrinkage case, the polymer-cement ratio exerted more influence on both flexural and compressive strengths than the content of powder shrinkage agent did.

  • PDF

A study on the improvable decision of saturated surface dry of fine aggregate (잔골재 표건상태 판정방법 개선에 관한 연구)

  • Song Ji-Heup;Cho Hyun-Dae;Choi Hyun-Soo;Jun Myoung-Hoon;Lee Do-Heun;Jaung Jae-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.153-156
    • /
    • 2005
  • Surface dry condition examination method on the KS F 2504(Testing method for specific gravity and absorption of fine aggregate) has dim detail prescriptions which can cause different ways of understanding based on one's convinence, not on correct means of rule. So we investigate the problems about the inconsistency on decisioing surface dry condition at management examination in the lab and scene. In conclusion, free-falling method is easier and faster than self-weight method. And we also found that the most important face on decisioning surface dry is compacting factor of tamping rod.

  • PDF

Study on Seepage Behavior of Concrete Faced Gravel-Fill Dam (표면차수벽형사력댐의 침투거동에 관한 연구)

  • Cho, Sung-Eun;Kim, Ki-Young;Park, Han-Gyu;Ha, Ik-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.836-841
    • /
    • 2008
  • CFRD (Concrete Faced Rockfill Dam) has been world-widely constructed due to a lot of advantages compared with rockfill dam and recently, sand/gravel materials, instead of crushed rock materials, are also utilized as a main rockfill material to overcome geological and environmental problems. In this paper, the process of water infiltration into the originally unsaturated sand/gravel-fill dam is studied using two-dimensional saturated-unsaturated seepage theory. According to the results of seepage analysis, if the effective drainage zone is installed in the dam, the reservoir water infiltrate into the dam along a downward flow path towards the lower drainage area. The main body constructed with sand/gravel materials, therefore, remains unsaturated.

  • PDF

Compressive Strength of Concrete due to Moisture Conditions of Recycled Coarse Aggregates and Curing Conditions (순환 굵은 골재의 함수상태와 양생조건에 따른 콘크리트의 압축강도)

  • Moon, Kyoungtae;Park, Sangyeol;Kim, Seungeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.485-492
    • /
    • 2019
  • In this study, the effect of moisture conditions of recycled coarse aggregates on the compressive strength of concrete was evaluated with the water/binder ratios and the curing conditions. The saturated recycled aggregates seemed to have the negative effect on the strength development of concrete. This is the because of the decrease in bond strength between aggregate and cement paste due to the increase of surface water according to the high absorption of recycled aggregates. The effect of types and moisture conditions of aggregates according to the change of water/binder ratio was similar. However, the curing conditions had a significant effect on the compressive strength of the concrete with the different types of aggregates. In the case of curing in air, the recycled aggregates with high absorption reduced the moisture required for hydration and increased the rate of vaporizing, and these result in interfering strength development. The moisture conditions of the recycled aggregates have a considerable effect on the compressive strength of the concrete, and it is necessary to control the moisture conditions of aggregates in the production of concrete with recycled coarse aggregate. And the control of the curing condition is very important for the concrete with recycled aggregate.

Evaluation of Failure Mode in Concrete Beam Restrengthened with GFRP with Various Initial Conditions (GFRP로 보강된 다양한 초기 조건의 콘크리트보의 파괴 거동 평가)

  • Jin-Won Nam;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2023
  • Various failure modes occur in the concrete beams reinforced with GFRP(Glass Fiber Reinforced Plastic) under initial condition and repairing patterns. In this study, the failure behaviors of concrete beams restrengthened with GFRP sheet with slightly higher elastic modulus than concrete were investigated. For the tests, concrete beams with 24 MPa were manufactured, and the effects of initial notch, overlapping, end-strip reinforcement, and fiber anchors were analyzed on failure load. The cases of GFRP overlap around notch and the initial notch showed increasing failure loads similar to those of normal restrengthened case since the epoxy of the saturated GFRP sufficiently repaired the notch area. Compared to the control case without restrengthening of GFRP, the concrete with initial notch showed 0.78 of loading ratio and normal restrengthening showed 4.43~5.61 times of increasing ratio of failure loading, where interface-debonding from flexural crack were mainly observed. The most ideal failure behavior, break of GFRP, was observed when end-strip over 1/3 height from bottom and fiber anchor were installed, which showed increasing failure load over 150 % to normal restrengthening.

Study on Effective Shielding of Secondary Radiation Generated by High Energy Proton Accelerator (고 에너지 양성자 가속기에서 생성되는 2차 방사선의 효과적인 차폐에 관한 연구)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.383-388
    • /
    • 2020
  • High-energy proton accelerators continue to be increasingly used in medical, research and industrial settings. However, due to the high energy of protons, a large number of secondary radiation occurs. Among them, neutrons are accompanied by difficulties of shielding due to various energy distribution and permeability. So In this study, we propose a shielding method that can shield neutrons most efficiently by using multiple-shielding material used as a decelerating agent or absorbent as well as a single concrete shielding. The flux of secondary neutrons showed a greater decrease in the flux rate when heavy concrete was used than in the case of ordinary concrete, and the maximum flux reduction was observed at the front position when using multiple shields. Multiple shielding can increase shielding efficiency more than single shielding however, As the thickness of the multiple shielding materials increased, the decline in flux was saturated. The mixture material showed higher shielding results than the polyethylene when using boron carbonate.

Evaluation of unsaturated soil slope stability by incorporating soil-water characteristic curve

  • Zhai, Qian;Tian, Gang;Ye, Weimin;Rahardjo, Harianto;Dai, Guoliang;Wang, Shijun
    • Geomechanics and Engineering
    • /
    • v.28 no.6
    • /
    • pp.637-644
    • /
    • 2022
  • Loess soils are unsaturated and widely distributed in the northwest zone in China. Many steep slope of unsaturated are observed are observed to be naturally stable. However, a low factor of safety (FoS) for these slopes would be computed from the slope stability analysis following local code practices. It seems that the analyzed results following the local code practices do not agree with the real condition as observed in the field. It is commonly known that soil suction plays an important role in slope stability due to a higher shear strength of the unsaturated soil as compared with that of the saturated soil. In this paper, it is observed that the computed FoS can also be affected by unsaturated unit weight of the soil. However, the effect of unsaturated unit weight of the soil on the slope stability is commonly ignored in engineering practice. Therefore, both the effects of shear strength and unit weight of the unsaturated soil on the computed FoS of unsaturated soil slope are investigated in this study. It is observed that the unsaturated unit weight of soil on the computed FoS increases with increase in slope angle. It is also observed that the effects of the unsaturated shear strength and unsaturated unit weight on the computed FoS are more significant than the effect of 3D analyses compared to the 2D analyses on the FoS.

Limit Equilibrium, Finite Difference, and Finite Element Analysis of Slopes (한계평형해석(LEM), 유한차분법(FDM) 및 유한요소법(FEM)을 이용한 사면안정해석)

  • Jeon, Sang-Soo;Lee, Choong-Ho;Oh, Mi-Hee;Gang, Sang-Wook;Pham, Nguyeon Quoc;Kim, Doo-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.199-206
    • /
    • 2005
  • Engineers have performed slope stability analyses, including Limit Equilibrium Analysis, Finite Difference Analysis and Finite Element Analysis. Each analysis results in different Factor of Safety(FS) for slopes. The comparison of FS results from these stability analyses has been carried out for various conditions, such as geometry of slopes, dry and fully saturated soils, nail and anchor reinforcements. Standard deviations of FS calculated from various slope analyses are 0.03 to 0.04 and 0.22 to 0.48 for the slopes without and with nail or anchor reinforcement, respectively. Construction of tiered concrete retaining wall in addition to nail or anchor reinforcement increases FS of 12% to 29% for fully saturated soils.

  • PDF

Durability of Polymers for Cement Modifier in Autoclave Cure (오토클래이브양생에 의한 시멘트 혼화용 폴리머의 내구성)

  • Joo, Myung-Ki;Lee, Youn-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.888-893
    • /
    • 2003
  • The purpose of this study is to make clear the durability of the polymer films formed in the autoclaved polymer-modified mortars and concretes. The polymer films prepared with polymer dispersions such as a styrene-butadiene rubber (SBR) latex, a poly (ethylene-vinyl acetate)(EVA) emulsion and a polyacrylic ester (PAE) emulsion for polymeric admixtures are exposed to autoclaving at 18$0^{\circ}C$ in temperature and 1.01 MPa in vapor pressure, and subjected to tensile test and infrared spectroscopy. The durability of the polymer films is evaluated from the application of autoclaving to the polymer films under saturated Ca(OH)$_2$ solution immersion causes no degradation for SBR films and a significant degradation due to the saponification of the polymers for EVA and PAE films. Accordingly, in the application of autoclaving to polymer-modified mortars and concretes, it is suggested that SBR-modified mortars and concretes are hardly degraded but EVA- and PAE-modified mortars and concretes are markedly degraded by the saponification of the polymers.

An Experimental Study on Characteristics of Averaged Electromagnetic Properties considering Moisture Changes in Cement Mortar (시멘트 모르타르의 수분변화에 따른 평균화된 전자기 특성에 대한 실험적 연구)

  • Kwon, Seung-Jun;Maria, Q. Feng;Na, Ung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • Many researches on electromagnetic (EM) properties like dielectric constant and conductivity are performed since they can be characterized in nonmetallic cement-based material such as mortar and concrete. However, they are much affected by the moisture so that the behaviors of EM properties are to be clearly understood. In this paper, measurements for saturation and EM properties are performed for cement mortar specimens with five different water to cement (W/C) ratios including basic tests like compressive strength and porosity measurement. Every saturated specimens are exposed to room condition and the changes in EM properties caused by decreasing saturation are analyzed. In the saturated condition, higher measurement of EM properties are evaluated in the specimens with higher porosity, however this relationship is adversely changed with drying process. Since the pores without filled water causes the decreases in EM properties, the measurements show stable and linear increment with the lower W/C ratios. Furthermore, the increasing ratios of EM measurements with W/C ratio are shown with saturation and the relationships between them are derived through regression analysis.