• Title/Summary/Keyword: saturable reactor

Search Result 11, Processing Time 0.029 seconds

A Effect of Saturable Reactor-Resistor Pair on High Power SCR Chopper (대전력 SCR 초퍼에서 가포하리액터-저항짝의 효과)

  • 강민구;조규형
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.7
    • /
    • pp.442-447
    • /
    • 1988
  • Saturable reactor-resistor pair is proposed as a part of snubber and applied to a hard commutation chopper. SCR turn off process is modeled to simulate the hard commutation chopper. State equations are derived for each mode of the chopper and they are solved by Runge-Kutta 4th order method. It is shown that the reverse voltage spike and reverse dv/dt can be minimized by applying saturable reactor-resistor pair to the chopper which controls peak reverse recovery current and damping factor. Saturable reactor-resistor pair can be used to reduced SCR power loss and value of snubber capacitor and can be applied to high power thyristor devices.

  • PDF

Study on EMTP Simulation Applying Dual Reactor for Prevention of the Ferro-resonance and VT Burnout in Substation System

  • Kim, Seok-kon;An, Yong-ho;Jang, Byung-tae;Choi, Jong-kee;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • When the line and switchgear of the substation system are disconnected, ferro-resonance can occur. This happens even if the capacitive reactance and inductive reactance are not equal, which are not common resonance conditions. Resonance conditions vary depending on the busbar configuration environment. Although the damping resistance method applying the existing saturable reactor to cope with ferro-resonance has been successfully applied on site, there can be loss of normal function during long-term operation. The reason is because the rise in the operating frequency of saturable reactors means the saturation number is increased. Therefore, it can no longer function as saturable reactor since the resistor having inadequate capacity is burned out. To address this problem, in this paper, an EMTP-based simulation test was performed by designing and applying a dual reactor method, which adds an extended divergence reactor to the 1st side of the VT. The test result confirms that when the divergence reactor is inserted, the voltage and current values obtained at the 1st side and 2nd side of the VT as well as current values of divergence reactor part were stabilized from the transient phenomena and return to normal values. When compared with existing measures, although this method is similar in adding having a reactor added to a system regarding ferro-resonance, it has the advantage of being able to prevent ferro-resonance in advance since the reactor is added before the system is saturated. In addition, because it does not use damping resistance, it can extend the equipment life and stabilize its operation. Therefore, there are a lot of differences in terms of its operating characteristics and achivement of goal between the conventional method and new divergence reactor method.

The Structure and Short Circuit Analysis of Saturable Magnetic Core Superconducting Fault Current Limiter (자기 포화형 고온 초전도 한류기의 구조 및 단락특성에 관한 연구)

  • 최석진;이승제;이찬주;이상진;현옥배;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.154-157
    • /
    • 2000
  • Superconducting tape easily can applied to distribution of electricity. It designs basic model of Saturable Reactor type Fault Current Limiter which used superconducting tape, and observes a specific character by means of simulation. Saturable Reactor type Fault Current Limiter is not influenced by saturation of Magnet core appeared in Induction Fault Current Limiter, because it exploit saturation of Iron core. But, it is possible that superconducting tape quenched when AC current flow to superconducting tape which biased DC voltage.

  • PDF

Parameter Selection of the Saturable Reactor for Removing Ferroresonance of 362kV Gas VT Using EMTP (EMTP를 이용한 362kV Gas VT의 철공진제거를 위한 가포화리엑터의 파라미터 선정)

  • Choi, Jae-Gu;Kim, Ik-Soo;Park, Kyoung-Won;Song, Hee-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • Recently, the construction of gas insulated substation(GIS)s has been increased in Korea. But, the whole quantity of the VTs which were used in GIS has been imported. Under the circumstance that $SF_6$ gas power apparatus are being developed up to 800kV rating in Korea, the development of EHV $SF_6$ gas VT is essential for localizing the power apparatus. As for EHV VT, destructive ferroresonance can be generated due to the combination of capacitiances between poles of circuit breaker, ground capacitance of bus and nonlinear excitation property of VT core. But the theoretical analysis about ferroresonance has not been fully achieved in Korea. Therefore, in this paper the authors would like to contribute for localizing EHV $SF_6$ gas VT by developing the diagram of ferroresonance zone according to the parameters of the circuit and the saturable reactor.

  • PDF

Design and Characteristics of Magnetic Amplifier (자기증폭기의 시형설계 및 동작특성)

  • 현경호;오명환;이광원
    • 전기의세계
    • /
    • v.20 no.3
    • /
    • pp.17-26
    • /
    • 1971
  • An experimental design of magnetic amplifiers and their characteristics in steady state are presented. A saturable reactor model having 2KVA capacity was designed, using Z-10 grain-oriented silicon steel which is commonly used in power transformers. Experimental and theoretical analysis show that the experimental results are in good agreement with the equal ampere-turns law. In addition to the saturable reactor, the self-saturated magnetic amplifiers of 0.4VA and 5VA capacity, using 50% Ni-Fe alloy cores having rectangular hysteresis loops were designed. Control characteristic curves of these amplifiers show high ampere-turn gain enough to be used for voltage controllers under load and non-contact magnetic switches of the rated capacity.

  • PDF

An Improved ZVS Partial Series Resonant DC/DC Converter with Low Conduction Losses (저 도통손실 특성을 갖는 향상된 영전압 부분 직렬 공진형 DC/DC 컨버터)

  • 김의성;이동윤;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.386-393
    • /
    • 2000
  • This paper presents an improved ZVS partial series resonant DC/DC converter (PSRC) with low conduction losses, suitable for high power and high frequency applications. The proposed PSRC have advantages of zero-voltage-switching (ZVS) of main switches for entire load ranges low conduction losses of main switches by decreasing current stresses. Also the reduction of the effective duty cycle is not occurred during the resonant period of the main circuit because the auxiliary circuit of the proposed converter is placed out of the main power path. The auxiliary circuit is composed with passive components, which are an inductor, two capacitors, two diodes, and a saturable inductor. An improved ZVS PSRC has so much characteristics with respect to the overall system efficiency and to the reduction of current stresses. The operation principles of the proposed converter are explained in detail and the various simulated and experimental results show the validity of the proposed converter.

  • PDF

Soft Switching PWM Converter Using a New Active Snubber (새로운 액티브 스너버를 이용한 소프트 스위칭 PWM 컨버터)

  • Cho, M.C.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Kwan, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.261-263
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

Development of Power Supply Unit for high power GTO driver (대용량 GTO 구동회로용 Power Supply Unit 개발)

  • Cha, J.D.;Yang, H.J.;Hong, S.W.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.609-612
    • /
    • 1996
  • This paper describes a design and implementation of the practical SMPS(Switched Mode Power Supply) with multi-output independent regulation scheme. The designed SMPS is applied to the PSU(Power Supply Unit) of high power GTO drivers for a inverter system. In order to accomplish precise voltage regulations for both turn-on and turn-off bias voltages of the GTO driver, the conventional forward type PWM converter scheme is adopted with the Post Regulator using a Saturable Reactor. Analytic design criteria and control schemes are described for practical applications. Finally, the precise regulation of multi-output voltages is proved by experimental results.

  • PDF

Topologies of hige freguency PWM DC-DC converter using a new active snubber (새로운 액티브 스너버를 이용한 고주파 PWM DC-DC 컨버터의 토플로지)

  • Cho, M.C.;Kim, C.Y.;Suh, K.Y.;Lee, H.W.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1010-1011
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber capacitor and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of the auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

New ZVZCS PWM Converter For High Power Application (대전력 응용을 위한 새로운 ZVZCS PWM 컨버어터)

  • Ryoo, Hong-J.;Cho, Jung-G.;Yoo, Dong-W.;Rim, Geun-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.521-524
    • /
    • 1996
  • A new zero voltage and nero current switching(ZVZCS) full bridge(FB) PWM converter b proposed to improve the performance of the previously presented ZVZCS-FB-PWM converters [7,8]. By adding a secondary active clamp and controlling the clamp switch moderately, ZVS(for leading-leg switches) are ZCS(for lagging-leg switches) are achieved without nay lossy components, the reverie avalanche break down of leading-leg IGBTs[7] or the saturable reactor in the primary[8]. Many advantages including simple circuit topology, high efficiency, and low cost mate the new converter attractive for high voltage and high power(> 10 kW) applications. The principle of operation is explained and analyzed. The features and design considerations of the new converter are also illustrated and verified on an 1.8 kW, 100 kHz IGBT based experimental circuit.

  • PDF