• 제목/요약/키워드: sanitary quality

검색결과 330건 처리시간 0.022초

상수도의 수질관리와 타소소독의 잔류효과에 관한 연구 (Study on the Water Quality Control of Water Supply the Reside: Effects of Chlorinations)

  • 유귀현
    • 환경위생공학
    • /
    • 제6권2호
    • /
    • pp.33-47
    • /
    • 1991
  • 1. Water supply treatment plants personnel could not test the water quality control, because most of them rely on the provincial health laboratories about water quality rely rant test. However, in future, plants have to been provided the facilities and equipment of water quality laboratory. 2. Chlorination methods are 89.5% of liquid chlorine and 10.5% of solid chlorine, and the cost per 1 $\m^{3}$ of chlorination is about 1.30 won which chlorination cost is very cheap as 1/142 of drinking water production cost. Input method of chlorine is 35% of automatic method, 56% of semi-automatic, and 9% of other methods, and this is no problem 3. Residual effects of chlorination, in the case of distilled water as a standardized material and 0.2 ppm of seperated residual chlorine, were continued 32 hours in $0^{\circ}C$, and 25 hour in $20^{\circ}C$, of water temperature and in the case of 0.4 ppm of seperated residual chlorine were continued 47 hours in $0^{\circ}C$ and 23 hours in $20^{\circ}C$. 4. In the case of 4 ppm of seperated residual chlorine, residual effects were continued 23 hours in $5^{\circ}C$, 90 hours in $10^{\circ}C$, 78 hours in $15^{\circ}C$, and 60 hours in $20^{\circ}C$ : by the temper; lure of water, continuing residual effects of chlorination are different, so we have to car for the warm season chlorination in the hider temperature. 5. Chlorination effects of drinking waters in the case of 0.4 ppm of seperated residual chlorine were continued 237 hours in $22^{\circ}C$ water : and in the case of rechlorination as 4 ppm of residual chlorine, continued 71 hours in $22^{\circ}C$ water.

  • PDF

QFD 기법을 이용한 병원 위탁급식 운영전략 수립 (Strategic Planning for the Contract-Managed Hospital Foodservice Through QFD Methodology)

  • 양일선;박수연;김현아;박문경;신서영;이해영
    • 대한지역사회영양학회지
    • /
    • 제8권5호
    • /
    • pp.744-754
    • /
    • 2003
  • At present, health care industries throughout the world are struggling with the challenges to set up financial structures as cost-effective ways and means of satisfying customer needs for health care services. Many hospitals consign foodservice management to foodservice companies for the purpose of efficiency. The companies taking charge of hospital foodservice are also striving to gain an advantage over keen competitions. This study applied Quality Function Deployment(QFD) to one hospital (which will be shown as $\ulcorner$A hospital$\lrcorner$ below) managed by a contract foodservice company for the purpose of strategy planning to provide sustainable competitive advantage. First of all, this study scanned internal and external environment of $\ulcorner$A hospital$\lrcorner$ by means of a Quality Measurement Tool and a fieldwork study. With the result of environment scanning, this study elicited 20 strategies through SWOT analysis, which were categorized by 4 perspectives such as financial, customer, internal process, learning and growth perspectives. Finally, the priorities of 20 strategies were extracted from QFD methodology. According to the results obtained by applying QFD to $\ulcorner$A hospital$\lrcorner$'s foodservice, the strategies which $\ulcorner$A hospital$\lrcorner$ foodservice was obliged to introduce and implement were : the specialization of Children's hospital foodservice, scientific foodservice management through the standardization of foodservice operations, the maintenance of sanitary quality through sanitary system, the remodeling of facilities, the introduction of new equipment, the prompt and accurate response to customer needs, the development of appropriate patient menus, the provision of competitively priced meals for patient selection, the development of a demand forecast model by considering the characteristics of a children's hospital, improvement of productivity and the reduction of labor costs through the employment of experienced employees based on their seniority.

시판 반염건 능성어(Epinephelus septemfasciatus)와 영상가이석태(Pseudotolithus typus)의 위생학적 품질 특성 (Sanitary Quality of Commercial Salted-dried Convict Grouper Epinephelus septemfasciatus, and Longneck Croaker Pseudotolithus typus)

  • 박권현;강상인;김민주;이수광;박선영;허민수;김진수
    • 한국수산과학회지
    • /
    • 제48권6호
    • /
    • pp.864-875
    • /
    • 2015
  • This study investigated the sanitary characteristics of commercial salted semi-dried convict grouper Epinephelus septemfasciatus (SSD-CG) and longneck croaker Pseudotolithus typus (SSD-LC) and suggested standards for salted semi-dried fish (SSD-F), based on the domestic standards for salted mackerel (Scomber japonicus or kwamegi) and salted dried yellow corvenia (Pseudosciaena manchurica), and sanitary characteristics of commercial SSD-F. For the commercial SSD-CG and SSD-LC, respectively, the moisture content ranged from 64.6-76.1 and 65.7-77.5%, salinity from 2.7-8.2 and 1.5-4.9%, volatile basic nitrogen (VBN) from 22.1-88.2 and 13.5-87.4 mg/100 g, peroxide value (POV) from 17.2-195.0 and 28.5-190.2 mEq/kg, and viable cell counts from 6.1-8.4 and 5.4-7.2 log (CFU/g). No Escherichia coli was detected in six kinds of SSD-CG or three kinds of SSD-LC. The standard for controlling the quality of SSD-F is the moisture content (>68%), salinity (>3%), VBN content (>50 mg/100 g), POV (>60 mEq/kg), viable cell counts (>$10^6$ CFU/g), E. coli (>MPN/100 g), and others. Using the established standards, no commercial SSD-F passed. The chemical, microbial, and other results for commercial SSD-F suggest that provisions for controlling the quality of high-quality SSD-F should be established.

시판 수산식품에 대한 세균학적연구 3. 냉동식품의 위생지표세균에 관하여 (BACTERIOLOGICAL STUDIES ON MAEKET SEA FOODS 3. Sanitary indicative bacteria in frozen sea foods)

  • 장동석;최위경;조권옥
    • 한국수산과학회지
    • /
    • 제8권3호
    • /
    • pp.157-165
    • /
    • 1975
  • 각종 수산냉동식품에 대한 위생지표세균의 오염도를 파악하고 나아가서 위생관리에 필요한 기초자료를 얻고자 1974년 3월부터 12월까지 부산시 소재 각냉동공장에서 가공된 장어, 보리별, 뱅어, 적어, 넙치, 피조개, 새조개, 새우, 굴, 명태 fillet등 12종 116시료를 수집하여 위생지표세균인 대양세균 분편계대장균, 분편계연쇄상구균, 장구균 및 일반생균수를 조사하였으며 특히 냉동 북양명태를 해동하여 fillet block로 재 동결할때 까지의 과정별로 세균의 소장을 시험하여 다음과 같은 결과를 얻었다. 1. 분편계대장균 MPN의 중앙치는 20이었고 장구균은 790이었으며 생균수의 중앙치는 $2.3\times10^4$이었다. 2. 각 위생지표세균의 오염도와 생균수사이에는 일정한 상관관계는 없었다. 3. 냉동품의 세균학적 품질을 측정하는데는 대장균 보다 장구균이 보다 명료할 것으로 생각되어진다. 4. Round혹은 semifillet 상태로 동결된 북양명태는 대부분 대장균군 음성이었으나 가공공정중에 많은 세균이 오염되었다. 5. $20^{\circ}C$배양균은 $35^{\circ}C$배양균보다 훨씬 많았으며 평균 14차 이상이었다. 6. 대장균군 MPN의 기하평균치는 310이었고 장구균은 142이었다. 7. 급속동결할때 세균의 감소율은 대장균군이나 35 배양균은 $50\%$이상이었으며 장구균이나 $20^{\circ}C$ 배양균은 약 $35\%$ 이었다. 8. 116시료중 분편계대장균 MPN 230 이상인 것은 $5,7\%$이었고 음성인 것은 $54.6\%$이었으며 생균수가 $1.0\times10^5$이상인 것은 $10.2\%$이었다.

  • PDF

미국 Washington주 Burley Lagoon에 있어서의 참굴, Crassostrea gigas과 그 서식수역에 대한 위생학적 연구 (A STUDY ON THE SANITARY QUALITY OF PACIFIC OYSTERS, CRASSOSTREA GIGAS AND GROWING WATERS IN BURLEY LAGOON, WASHINGTON)

  • 김성준
    • 한국수산과학회지
    • /
    • 제7권2호
    • /
    • pp.41-51
    • /
    • 1974
  • 참굴(Crassostrea gigas) 수하식양식에 있어 상층과 저층 그리고 조석에 따른 해수 및 굴의 위생학적 성상에 관한 변화를 조사하였으며 본 연구는 미국국제연맹처(AID) 연수계획에 의하여 Washington주 Burley Lagoon 뗏목 수하식 양식장에 대하여 실시되었다. 해수의 수온, 염분 및 탁도는 저층이 상층보다 다소 높았고 그 차이는 수온 $0.3^{\circ}C$, 염분 $0.5\%_{\circ}$, 탁도 0.1 JTU 있다. 조석에 따를 수온 및 염분의 변화는 대체로 조석 주기에 일치하는 기복상을 보였다. 해수의 위생지표미생물 함양은 상층이 저층보다 대체로 높았고 일반적으로 Coliform MPN 및 Fecal coliform MPN의 변화는 조고에 역비례하고 있어 이들 미생물군의 출처는 이 해역으로 유입하는 하천임을 알 수 있다. $35^{\circ}C$ Plate count는 조석 변동에 대하며 보다 안정하였다. 굴에 있어 Coliform 및 Fecal coliform MPN의 평균치는 상층굴이 저층보다 일반적으로 높은 값을 시현하였으나 $35^{\circ}C$ Plate count는 이와 같은 경향을 나타내지 않았다. 해수에서와 같이 굴에 있어서도 Coliform 및 Fecal coliform MPN의 평균치는 양자 모두 호고에 역상관관계를 나타내었고 조사기관중 굴의 세균축적비는 Coliform MPN은 $8.6\~19.7$, Fecal coliform MPN은 $16.9\~44.3$이였다. 이상의 결과로서 굴수하식 양식에 있어 패류위생관리상 중요한 것은 창호시에 굴을 채취하는 것이 미생 지표 세균의 함량이 보다 낮다는 것을 들 수 있다.

  • PDF

정수장 색수의 처리기법에 관한 연구 (A study on colored water treatment at purification plant)

  • 박송인;이지헌;이해훈;김환범;안길원;박귀임;김양기;배주순;문희;박철웅;오은하;서윤규
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.55-61
    • /
    • 2001
  • There are many reservoirs used as the source of water supply and they show various specific characteristics in water quality depend seasonal. Especially, there were not a little variations of water quality in summer, as a natural consequence it follows that stratification occured phenomenon and changed anaerobic condition in the bottom of reservoir, and then accumulated Fe and Mn substance in soil and sediment were resolved into water, it attributes to coloration. G purification plant located in Y gun is very small plant in which coloration occurs by Fe and Mn in every summer. Using this plant as a model, the removal methods of Fe and Mn were studied. After prechlorination plus LAS coagulation, Fe, Mn, $NH_3-N$ were decreased from 7.290 mg/l to 0.080 mg/l, from 0.480 mg/l to 0.075 mg/l, from 0.55 mg/l to 0.04 mg/l. But $THM_{s}$ was increased from 0.050 mg/l to 0.044 mg/l. It shows that the prechlorination plus LAS coagulation treatment process in purification plant is effective to remove Fe and Mn ion.

  • PDF

Comparative performance evaluation of two UF pilot plants at the Alto da Boa Vista WTP (São Paulo, Brazil)

  • Oliveira, T.F.;Mierzwa, J.C.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.175-185
    • /
    • 2011
  • Ultrafiltration is an emerging technology for drinking water treatment because it produces better water quality as compared with conventional treatment systems. More recently, the combination of UF technology with other processes in order to improve its performance has been observed. These associations aim to maximize the contaminants removal and reduce membrane fouling. The operational performance of contaminants removal and water production of two UF pilot plants was compared. The first plant (Guarapiranga) was fed with raw water and the second plant (ABV) with pre-treated water by the coagulation, flocculation and sedimentation processes at Alto da Boa Vista WTP (Sao Paulo, Brazil). Both units operated continuously for approximately 2,500 hours, from September/2009 to January/2010. The results showed that the ABV UF pilot plant was able to operate at higher specific fluxes (6.2 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$) than Guarapiranga (3.1 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$). However, the number of chemical cleanings conducted in both pilot units during the considered operation period was the same (4 chemical cleanings for each plant), which shows that the pre-treatment reduced the membrane fouling. The water quality at ABV for all the variables analyzed was better, but the feed water quality was also better due to pretreatment. The rejection values for the different contaminants were higher at Guarapiranga mainly because of a pollution load reduction after pre-treatment at ABV. Even with the better performance of the ABV UF pilot plant, it is necessary to take into consideration the complexity of the complete treatment system, and also the costs involved in the construction and operation of a full-scale treatment unit.

주암호 조류 분포의 계절별 변화에 관한 연구 (Studies on Seasonal Variation of Algae Distribution in the Chuam Reservoir)

  • 정진;조영관;김종선;이진종
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.1-13
    • /
    • 1998
  • Seasonal variation of algae distribution were studied in the Chuam reservoir from August 1996 to July 1997. As a result, 127 taxa were observed, representing 6 classes, 14 orders, 5 suborders, 29 families, 2 subfamilies, 54 genus, 118 species, 7 variaties and 2 formula. The majors of them are Chlorophyceae (59 taxa), Bacillariophyceae(39 taxa) and Cyanophyceae(20 taxa). The number of species was that 35 and 31 taxa were occurred in August 1996 and April 1997, 11 and 17 taxa in July 1997 and October 1996 respectively at Dam station, 53 taxa were occurred in September, 18 taxa in November at Munduck station. The biomass composition of occurrence species were as fallowes; Cyanophyceae are 80%, Bacillariophyceae 14% and Chlorophyceae 5% at Dam station and Cyanophyceae are 90%, Bacillariophyceae 1.3% and Chlorophyceae 0.4% at Munduck at Munduk station. At Munduk station, water bloom occurred by Cyanophyceae(99.9%, 3.7 $\times$ 10$^{7}$ cells/L) in November 1996 and the major causing algae was Microcrystis aeruginosa. Microcystis aeruginosa was dominant species (dominant index : 0.72 - 0.99) during summer and autumn, Fragilaria crotonensis and Asterionella formasa (DI : 0.33 - 0.74) during winter and spring. The water quality factors of the Chuam reservoir were that the values of water temperature ranged of 3.6 - 31.4$\circ$C, pH 6.7 - 9.0, conductivity 69.6-118.2 $\mu $s/cm, and turbidity 1.0-22.5 NTU, and the proper temperature of water for algae growth was 15 and 16.7$\circ $C in April and November. Also the concentration of dissolved oxygen(DO) ranged of 6.8-15.5mg/L, total nitrogen(T-N) 0.54-1.78 mg/L, total phosphrous (T-P) 0.003-0.034 mg/L, and chlorophyll-a 0.9-23.2mg/m$^{3}$. The concentration of Chlorophyll-a was in inverse proportion T-N/T-P ratio.

  • PDF

반도체 산업폐수의 재이용 기술에 관한 연구 (A Study on the Waste Water Recycling Technology for Semiconductor Industry)

  • 지은상;김재우;신대윤
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.137-142
    • /
    • 1999
  • Current semiconductor industry factories are relying on the end-of-pipe treatment technology for waste water treatment and thus they mostly suffer from severe industrial water shortage. As a result in order to solve those waste and industrial water problems, there requires to be changed to the Clean Technology, that is Pollution Prevention Technology. Through above strategic actions with the Clean Technology, we shall strength more powerful and logical environmental pollution prevention system than those in the past. By changing the end-of-pipe treatment technology for waste water treatment and thus they mostly suffer from severe industrial water problems, there requires to be changed to the Clean Technology, that is Pollution Prevention Technology. Through above strategic actions with the Clean Technology, we shall strength more powerful and logical environmental pollution prevention system than those in the past. By changing the end-of-pipe treatment technology with physical, chemical and biological treatment methods as a mixed stream basis for treating of semiconductor waste stream into clean technology with pollution prevention technology as a waste segregation basis, we can bet 20 to 30% investment reduction as compared with end-of-pipe treatment technology.The results for water quality analysis were as follows : 1. Water quality analysis of the before treatment : pH : 9~10.5, Conductivity : $300~7,000{\mu}s/cm$, TDS : more then $3,000mg/{\ell}$, COD : $200~250mg/{\ell}$, SS : $500~600mg/{\ell}$, n-H : $8.3mg/{\ell}$ 2. Water quality analysis of the after treatment : pH : 6.5~7.5, Conductivity : 0.059, TDS : $40{\mu}s/cm$, COD : $20mg/{\ell}$, SS : $5mg/{\ell}$ n-H : $0.6mg/{\ell}$

  • PDF

Daily influent variation for dynamic modeling of wastewater treatment plants

  • Dzubur, Alma;Serdarevic, Amra
    • Coupled systems mechanics
    • /
    • 제9권2호
    • /
    • pp.111-123
    • /
    • 2020
  • Wastewater treatment plants (WWTPs) with activated sludge system are widely used throughout the most common technologies in the world. Most treatment plants require optimization of certain treatment processes using dynamic modeling. A lot of examples of dynamic simulations require reliable data base of diurnal variation of the inflow and typical concentrations of parameters such as Chemical Oxygen Demand (COD), Total Kjeldahl Nitrogen (TKN), etc. Such detailed data are not available, which leads to problemsin the application of dynamic simulations. In many examples of plants, continuous flow measurements are only performed after the primary clarifier, whereas measurements from influent to the plant are missing, as is the case with the examples in this paper. In some cases, a simpler, faster and cheaper way can be applied to determine influent variations, such as the "HSG-Sim" method ("Hochschulgruppe Simulation"). "Hochschulgruppe Simulation" is a group of researchers from Germany, Austria, Switzerland, Luxembourg, Netherlands and Poland (see http://www.hsgsim.org). This paper presents a model for generating daily variations of inflow and concentration of municipal wastewater quality parameters, applied to several existing WWTPs in Bosnia and Herzegovina (B&H). The main goal of the applied method is to generate realistic influent data of the existing plants in B&H, in terms of flow and quality, without any prior comprehensive survey and measurements at the site. The examples of plants show the influence of overflow facilities on the dynamics of input flow and quality of wastewater, and a strong influence of the problems of the sewerage systems.