• Title/Summary/Keyword: sanitary apparatus

Search Result 18, Processing Time 0.019 seconds

Evaluation of the Management of Sanitation in Food Service Establishments in Korea and Strategies for Future Improvement (국내 급식위생관리의 현황고찰 및 발전방안)

  • 김종규
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.3
    • /
    • pp.186-198
    • /
    • 2000
  • The quality of the management of sanitation in food service establishments (school lunch programs, hospital patient food services, and commercial catering food services) in Korea was reviewed and evaluated, and ten strategies fur future improvement were suggested. They were: (1) An increase of qualified manpower and improvement of the professional training of the staff; (2) Obtaining special facilities exclusively for food service; (3) Improvement of facilities especially the kitchens; (4) Improvement of policy fur procuring raw materials and being assured of their quality by designing some standards and specifications for the raw materials to be purchased; (5) Production and use accurate and reliable kitchen apparatus and instruments; (6) An increase of the laboratory apparatus and instruments for inspection and evaluation of the sanitary level of raw materials and food service environments; (7) Enforced improvement of personal hygiene of the staff; (8) Use of a variety of methods in sanitary education and training; (9) Actively inspect the quality of imported foods; (10) Strengthening the research and accumulation of background data regarding sanitation management. There is a long process from the production of food to eating. The cooking process is the ultimate end of preparation of food before eating. This process sometimes increases the occurrence of food-borne diseases if we mishandle the food, even we obtained safe food. The process can also remove health hazards and reduce the risk from the hazards if we handle the food well although we have unsafe foods. This means the cooking process is a major key to preventing food-borne diseases. The concepts of hazard analysis critical control point (HACCP) should be applied and practiced in food service establishments in Korea as soon as possible.

  • PDF

The Settlement Characteristics of Waste Landfill Site by Consolidation Test (압밀시험에 의한 쓰레기매립지의 침하특성)

  • Shin, Bang-Woog;Lee, Bing-Jik;Bae, Woo-Seok;Lee, Jong-Kyu;Ahn, Byung-Chul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • The settlement characteristics of waste landfill site must be considered in the design of sanitary landfill as well as in the course of the rehabilitation of the landfill site. Among prediction methods for settlement of landfill site, especially Gibson and Lo model and Power Creep Law have been successfully applied to the landfill site where the amount of settlement was large and the secondary settlement was obvious. Therefore, the effects of organic content on the model parameter values utilized in both Gibson Lo model and Power Creep Law were studied by using a large consolidation testing apparatus. The organic content is each 20%, 40%, 60% of total volume and consolidation load is $0.1{\sim}1.6kg/cm^2$. The main results can be summarized as follows: (1) The reference compressibility of Power Creep Law is decreased according to the increments of consolidation load: (2) The field measurement is more similar to the Power Creep Law than the Gibson and Lo model.

  • PDF

A Study on the Combined Treatment of Municipal Solid Waste Landfill Leachate (도시폐기물매립지침출수의 병합처리에 관한 연구)

  • 김동민;이병인
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.45-55
    • /
    • 1996
  • An experimental research was conducted in order to study the combined treatment o of municipal landfill leachate and municipal sewage. The landfill leachate was that of Nanjido landfill site, and the municipal sewage was that of Chungnang municipal sewage treatment plant in Seoul. Several sets of bench~scale sequencing batch reactor(SBR) were used as e experimental apparatus. Specially investigated items in this experiment were the removal efficiency of substrate and the influence of treatment time. The experiment lasted for about 2 years. The result are as follows ; 1. The characteristics of leachate were pH 7.5~8.2, BOD 80~336mg/L, COD 908~1,460mg/L, NH3-N 1,409~2,330mg/L, T~P 2.7~7.lmg/L, Cl~3,540~4,085mg/L, a and heavy metals are a very small amount. And the characteristics of sewage were pH 6.9~7.3, BOD 78.4~129.3mg/L, COD 121.2~305.0mg/L, T~N 14.9~36.4mg/L, T-P 2.3~8.9mg/L. 2. The treatability of leachate alone was not treat well. So for the good treatment of leachate, it was necessary to deal with the pretreatment before bi이ogical treatment and a combined treatment of municipal sewage. 3. The various contents of the leachate were 5%, 10%, 30%, and 50%, and the removal efficiency of COD was 86.0%, 82.8%, 60.6%, and 31.7%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 10% of that of sewage. And the removal efficiency of COD increased n notably, as its treatment time increased. 4. The various contents of the electrolytic treated leachate were 5%, 10%, 30%, and 50%, and the removal efficiency of COD was 89.9%, 86.1%, 79.2%, and 69.8%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 30 % of that of sewage. And the removal efficiency of C COD increased notably, as its treatment time increased.

  • PDF

Application of Analytical Instrument Method for Determining Level of Malodorous Sulfur Compounds. (악취성분중 황화합물에 대한 기기분석법의 적용)

  • 유병태;최종욱;조기찬;이충언;김건흥
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.117-123
    • /
    • 1999
  • The analytical instrument method was applied to analyze malodorous sulfur compounds emitted from industrial fields. Six factories and two sites which release malodorous substances into ambient air were selected to determine the level of hydrogen sulfide($H_2S$), methylmercaptan(MeSH), dimethyl sulfide($Me_2S$), and dimethyl disulfide($Me_2S_2$) using automated thermal desorption system (STD400) and GC-FPD in summer and fall seasons of 1999. The Air sampler for ATD400 uses a small pump to draw sample and a mass flow controller to adjust sample amount without using a dilution apparatus. The trap temperature of ATD400 reached to $-80^{\circ}$ by supplying liquid nitrogen and $H_2S$ can be analyzed under this condition. The recovery rates of $H_2S$, MeSH, $Me_2S$, and $Me_2S_2$ of odorous sulfur compounds standard were shown 98.2%, 93.6%, 98.2%, 99.4% respectively. The concentrations of $Me_2S$ at outside boundary of G market, L factory, and J factory were 0.018ppm, 0.021ppm, 0.032ppm in summer, respectively. The concentration of $H_2S$ at Nanjido landfill was 1.167ppm in summer, but that of $H_2S$ was not detected in fall because of soil covering. The concentration of H2S and $Me_2S_2$ at inside of Chonggye stream were 0.564ppm and 1.045ppm in summer, while those of H2S and Me2S2 were 0.285ppm and 0.465ppm in fall, respectively.

  • PDF

Microbial Contamination of Seasoned and Dried Squid Dosidicus gigas during Processing (조미오징어(Dosidicus gigas)의 가공 공정 중 미생물 오염도 및 오염원에 관한 연구)

  • Choi, Kyoo-Duck;Park, Uk-Yeon;Shin, Il-Shik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.5
    • /
    • pp.445-453
    • /
    • 2012
  • This study examined microbial contamination during seasoned and dried squid Dosidicus gigas processing, including the apparatus, machines, and employee's gloves at each step in processing at two companies. The numbers of bacteria floating in air in each processing area were also examined. The numbers of Staphylococcus aureus (3.6-6.0 log CFU/g) and Escherichia coli (1.3-1.4 log MPN/100 g) in domestic and imported daruma (a semi-processed product of seasoned and dried squid) at companies A and B exceeded the regulatory limits of the Food Sanitary Law of Korea (S. aureus, ${\leq}2.0$ log CFU/g; E. coli, negative). S. aureus in both daruma was reduced to below the detection limit or 3.6 log CFU/g after the roasting step, but increased again to 3.3 and 5.5 log CFU/g after the mechanical tearing step at companies A and B, respectively. E. coli showed similar tendencies at both companies. The surfaces of the apparatus, machines, and employee's gloves that contacted daruma were also contaminated with S. aureus (1.0-5.5 log CFU/$m^2$) and E. coli (negative-to 3.5 log MPN/$m^2$). The numbers of bacteria floating in air were high (1.7-5.1 log CFU/$m^3$) at both companies. These results suggest that sanitation standard operating procedures (SSOP) must be developed to control of microbial cintamination in seasoned and dried squid.

Analysis of Overviews of Working Environment Measurement and its Results in Korean Industry (우리나라 사업장의 작업환경측정 및 노출기준 초과실태 분석)

  • 김정호;원정일
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.53-61
    • /
    • 1996
  • The subject of this study was to analyse overviews of companies which exceed TLV by industry, hazardous factors, and to estimate the numbers of companies measured in 1993 and the implementation rate of working environment measurement by the act of industrial safety and health The result of this study was as follow. 1. The number of cases which exceed TLV was 5,937 companies. In distribution of excess companies by the scale of workers, small scale cases under the 49 workers were 3,150 companies(53.0%) of total cases, medium scale cases between 50 - 299 workers were 2,248 companies(37.9%), and large scale cases over 300 workers were 539 companies(9.1%). By the industry of excess companies, it was marked high rate in manufacture of fabricared metal products(except machinary and equipment), manufacture of textiles of each 1,048 companies(17.7%), and 1,018 companies(17.1%). By the area of excess companies, it was shown high rate in Kyeongki area marked 1,679 companies(28.3%) and Daegu-Kyeongbuk area were marked 1,417 companies (23.9%). By the hazardous factors of excess companies, noise was recorded high rate in 5,160 companies (86.9%), dust was shown in 1,245 companies(21.0%), organic solvent was marked 130 companies(7.9%). The number of excess factors by the company was 1.2. In this result, the more it was bigger scale companies, the more excess factors were much more and the more it was recorded higher rate in noise organic solvent heavy metals, etc. 2. The measured cases in institutes during 1994 were 1,596 companies, and excess cases were 157 companies(9.8%) among them. By the scale of workers, small scale cases under the 49 workers were 190 companies (17.9%) among 1,064 companies, cases of medium scale cases between 50-299 workers were 127 companies (27.9%) among 463 companies, and large scale cases over 300 workers were 31 companies(44.9%) among 69 companies. In this result industry of the highest rate shown was manufacture of basic metals in 20 companies exceeded among 53 companies (37.7%), and was manufacture of pulp, paper production in 14 companies exceeded among 40 companies(35.0%), and the excess rate were high in bigger scale. 3. Companies estimated by the data of excess cases and excess rate in 1993 were 30,474 implementation rate estimated for measurement of working environment was 34.3% of companies in korean industry. In this result, it was comparatively shown of measurement rate for the working environment in manufacture of pulp, paper product, manufacture of machinary and equipment n.e.c., and of high measurement rate and excess rate in manufacture of electrial machinary and apparatus, and manufacture of basic metals.

  • PDF

Assessment on HACCP Recognition & Sanitary Management of the Industry Foodservice Manager in Seoul (식품 위해 요소 중점 관리 기준에 대한 서울 지역 사업체 급식 관리자의 위생관리평가)

  • 이헌옥;심재영;김영경;조민호;최호순;엄애선
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.542-548
    • /
    • 2001
  • Hazard Analysis Critical Control Point(HACCP) is becoming an important component of food safety worldwide. The aim of this study was to investigate comprehensively the education and knowledge level of food service managers on HACCP as well as applying HACCP system to industrial foodservice. Total 247 foodservice managers participated in the survey and 159 responses were used for analysis. The results were as follows: 1) 89% of foodservice managers were educated about HACCP, and 40.9% felt they did fully understand HACCP and 47.8% did half. 2) The score for the implementation of HACCP was in the order of apparatus and facility sanitation, personal sanitation, and time-temperature/etc. sanitation. 3) Foodservice managers who were taught HACCP kept a deep attention to food and personal sanitation, compared with those without education(p<0.05). However, the education time on HACCP affected conducting safety management. The results suggest that education and understanding of HACCP are positively related, and understanding of HACCP has a positive influence on conducting safety management.

  • PDF

Control of Microorganisms in School Refectories and Kitchens Using Ozone Water and Ozone Gas (오존수 및 오존가스를 이용한 학교급식에서의 미생물 제어)

  • Choi, Jin-Kyung;Shin, Il-Shik;Kim, Dae Uk;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.586-592
    • /
    • 2015
  • This study was performed to determine optimum approaches for control of microorganisms in school refectories and kitchens. A reduction of more than 5.0 log CFU/mL was noted for Escherichia coli O157:H7, Salmonella Typhimurium, Listeria monocytogenes, Staphylococcus aureus, and Streptococcus mutans after treatment with 5 ppm ozone water for 60 s. Treatment of different vegetables with ozone water for 5 min showed bactericidal effects with 2-4 log reduction of viable cell number; the bactericidal effects differed according to the kinds of vegetables. The viable cell number on kitchen apparatus and tableware was not detected by ozone water treatment for 60 s. In addition, the count of the bacteria floating in the air in refectories and kitchens decreased 2.0 log CFU/1,000 L air to 0-1 CFU/1,000 L air on treatment with 45 ppm ozone gas for 12 hr. Therefore, ozone water and ozone gas may be good candidates as antimicrobial agents that can be used to improve sanitary conditions in school refectories and kitchens.