• Title/Summary/Keyword: sandwich wall panel

Search Result 27, Processing Time 0.025 seconds

Fatigue Fracture Assessment of Honeycomb Composite Side-Wall Panel Joint for the KTX Tilting Car Body (틸팅차량용 KTX 차체의 하니컴복합재 측벽판 체결부의 피로파괴평가)

  • Jeong, Dal-Woo;Kim, Jung-Seok;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • The honeycomb composite joint structure designed for application to a tilting KTX railroad car body is subjected to bending loads of a cantilever type. Honeycomb sandwich composite panel-joint attached in the real tilting car body was fabricated and sectioned as several beam-joint specimens for the bending test. The fracture behaviors of these specimens under static loads were different from those under cyclic loads. Static bending loads caused shear deformation and fracture in the honeycomb core region, while fatigue cyclic bend loading caused delamination along the interface between the composite skin and the honeycomb core, and/or caused a fracture in the welded part jointed with the steel under-frame. These fracture behaviors could occur in other industrial honeycomb composite joints with similar sub-structures, and be used for improving design parameters of a honeycomb composite joint structure.

A Farm on Broiler Chickens' Welfare in Korea (동물복지 관련 육계농가 실태조사)

  • Cheon, Si-Nae;Lee, Jun-Yeob;Choi, Yang-Ho;Park, Kyu-Hyun;Kim, Doo-Hwan;Song, Jun-Ik;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • We conducted investigations of the information and welfare of broiler chickens in Korea. The livestock housing of all broiler chicken farms were windowless type, bell feeder and nipple waterer were used, and stocking density was relatively higher (ranging from 18.2 $birds/m^2$ to 24.2 $birds/m^2$) than RSPCA's welfare standards for chicken hens (less than 19 $birds/m^2$). The ratios of sandwich panel, urethane form, slate, and steel plate in roofing materials were 61%, 21%, 13%, and 5%, respectively. The ratios of sandwich panel, urethane form, brick, and steel plate in wall materials were 61%, 21%, 13%, and 5%, respectively. The ratios of soil and concrete in flooring materials were 10% and 90%. The mist spray, fan, and cooling pad in cooling facilities were 42%, 32%, and 26%, respectively. Thus we believe that present data contribute to develop the animal welfare certification for broiler chickens and to improve animal welfare in Korea.

The changing characteristics of Material and Structure of Rural Housing in the aspect of Period and Region (지역별·시기별 농촌주택의 재료 및 구법 특징 변화 연구)

  • Bae, Woong-Kyoo;Joo, Dae-Khan;Jeong, Dong-Seop;Yun, Yong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6504-6513
    • /
    • 2013
  • The result can be summarized as follows. First, the following periodically changing characteristics were examined:roof form(gambrel/hipped-flat-gable), structure of roof and wall(wood-framed-cement masonry-RC-Light iron framed), roof material(thatched-tiled-slate-cement/steel sheet-asphalt/sandwich panel/mortar water-proofing), wall material(clay plaster/lime plastered-dressing tile/bricks-painting on the cement plastering-native stone dressing/siding/tile), fence material(masonry of stone and cement bricks), and courtyard materials(clay and concrete). Secondly, the regionally changing characteristics of those elements, rural housing structure, roof form, roof structure material, wall finishing material, fence and courtyard material in the outer space, differed according to the location of rural housing, i.e.north, middle, south region. The changing characteristics of both the roof structure and wall structure are similar to those of the three regions.

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

The Residential Space Transformation of Vernacular Houses with 田-shaped Floor Plan according to the Housing Life Change at Gangreung Area (강릉지역 전(田)자형 민가의 주생활 변화에 따른 주거공간의 변형)

  • Choi, Jang-Soon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.49-56
    • /
    • 2018
  • The vernacular houses with 田-shaped floor plan at Gangreung have been played important roles in tracing the vernacular living cultures including housing life. But due to the adoption of convenient facilities in vernacular housing lives caused by modernization and urbanization, many changes and transformations have happened at residential space of vernacular houses. This thesis targets to extract basic data to prepare and prevent various problems in process of renovation, extension and function change as installing housing life facilities, and to identify the changes and transformations of them to prepare the proper balances between their original form preservation and residents' convenience living. The results are as follows. The inner wall removal of rooms, the fuel change of cooking and heating, the leveling change of kitchen floor made possible the sedentary lifestyles. And its residential rooms were transformed from two row to one row by inner wall removal, the fuel heating change, the heating method change and the heat insulating materials. The residential extension materials were changed from the traditional materials such as soil, wood, etc to the modern materials such as cement block or brick, sandwich panel, etc. And the modern materials were used and attached to widen residential spaces to the vernacular house because of the easiness of execution. So, it is necessary for 田-shaped floor plan vernacular house owners to distribute printed execution guide book to prevent and minimize the various problems to be shown by extension, renovation and function change.

A Study on Effect of Anchor Plate on Concrete Breakout Capacity and Elasticity-Based Analysis Model of Anchor Plate (앵커플레이트가 콘크리트 파괴 강도에 미치는 영향 및 탄성기반 해석 모델에 대한 연구)

  • Shin, Ji-Uk;You, Young-Chan;Choi, Ki-Seon;Kim, Ho-Ryong;Kim, Jun-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.381-388
    • /
    • 2013
  • This study presents that effect of anchor plate on concrete breakout strength was evaluated. The addition of the anchor plate is to improve the concrete breakout capacity for a single anchor system in a thin-walled concrete panel (Insulated concrete sandwich wall panel). In this study, an elasticity-based simplified model was developed and used to predict effect on the anchor plate. Flexural stresses of the plate with respect to the concrete breakout strength obtained from CCD (Capacity Concrete Design) approach were compared with the test results. Through the test results, while the concrete breakout strength was improved due to increment of the width and thickness of the anchor plate, improvement of the strength was steadily declined. In addition, the It was observed that the analytical and experimental flexure of the anchor plate was comparatively in good agreement using the simplified elastic analysis model.

Analysis of Environmental Design Data for Growing Pleurotus ervngii (큰 느타리버섯 재배사의 환경설계용 자료 분석)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2005
  • This study was carried out to file up using effect and requirement of energy for environmental design data of Pleurotus eryngii growing houses. Heating and cooling Degree-Hour (D-H) were calculated and compared for. some Pleurotus eryngii growing houses of sandwich-panel (permanent) o. arch-roofed(simple) type structures modified and suggested through field survey and analysis. Also thermal resistance (R-value) was calculated for the heat insulating and covering materials of the permanent and simple-type, which were made of polyurethane or polystyrene panel and $7\~8$ layers heat conservation cover wall. The variations of heating and cooling D-H simulated for Jinju area was nearly linearly proportional to the setting inside temperatures. The variations of cooling D-H was much more sensitive than those of heating D-H. Therefore, it was expected that the variations of required energy in accordance with setting temperature or actual temperature maintained inside of the cultivation house could be estimated and also the estimated results of heating and cooling D-H could be effectively used far the verification of environmental simulation as well as for the calculation of required energy amounts. When the cultivation floor areas are all equal, panel type houses to be constructed by various combinations of materials were found to by far more effective than simple type pipe house in the aspect of energy conservation maintenance except some additional cost invested initially. And also the energy effectiveness of multi-span house compared to single span together with the prediction of energy requirement depending on the level insulated for the wall and roof area could be estimated. Additionally, structural as well as environmental optimizations are expected to be possible by calculating periodical and/or seasonal energy requirements for those various combinations of insulation level and different climate conditions, etc.