• Title/Summary/Keyword: sandpaper

Search Result 55, Processing Time 0.027 seconds

A study on adhesion properties between composite material and aluminum according to the physical surface treatment technique (물리적 표면처리 기법에 따른 복합소재 및 알루미늄간 접합특성 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.334-339
    • /
    • 2020
  • In this study, the adhesion properties between aluminum and composite materials, composite materials, and composite materials were compared according to the physical surface treatment to improve mechanical bonding at the bonding surface when considering carbon fiber and glass fiber-reinforced composite materials. Bonded specimens were classified into the type of base material and the surface treatment method of the bonding surface. Sandpaper, sandblasting, and plasma were applied as physical surface treatment methods. The bonded specimen was prepared as a single lap joint test specimen. An experiment to measure the lap shear strength was conducted, and the results were compared. The experimental results confirmed that the mechanical abrasion and sandblasting treatment improved the lap shear strength approximately 4 to 5 fold compared to the general specimen without physical surface treatment. In plasma treatment, the experiment was conducted by defining the respective plasma output and treatment time as follows: 150 W and 5 minutes, 150 W and 10 minutes, and 300 W and 3 minutes. Moreover, the lap shear strength results were similar to the previous mechanical surface treatments. On the other hand, the effect on the adhesion properties was small, depending on the plasma treatment conditions.

A Study on the Manufacturing, Mechanical Properties,Abrasion Resistance, and Slow Crack Growth Resistance of the Recycled Polyethylene/Fly Ash Composites (재생 폴리에틸렌/비산회 분말 충전 복합체 제조와 기계적 물성, 내마모성 및 저속균열성장 저항성에 관한 연구)

  • Kye, Hyoung-San;Shin, Kyung-Chul
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.335-342
    • /
    • 2011
  • The virgin and recycled polyethylene composites with various ratio of fly ash were manufactured by using a fully intermeshing co-rotating twin screw extruder for the reuse of fly ash from power plant and post-consumed polyethylene. Fly ash were blended with virgin HDPE and recycled polyethylene at the weight fraction of 0 to 40 wt.%. Mechanical properties such as yield strength, abrasion resistance, and slow crack resistance were measured with ISO and ASTM standards. The experimental results for the various composites showed that the elongation at break and the yield stress of the composites decreased with increasing fly ash contents. Generally, the abrasion resistance of PEs decreased with increasing sandpaper grits but the abrasion resistance of the composites increased with fly ash content at finer abrasive surface. The slow crack growth resistance of virgin HDPE, recycled JRPE and the JRPE composite showed higher slow crack growth resistance up to 50% of load at notch depth of 20% and 30%, but KRPE and the KRPE composite showed much lower resistance than virgin HDPE, JRPE and the JRPE composite. Time to break, measured with NCLS test method, of all PEs and the composites satisfies the regulation of Korean Industrial Specification for sewer pipe and support application.

An Evaluation of Human Sensibility on Perceived Texture for Real Haptic Representation (사실적인 햅틱 표현을 위한 질감지각 감성 평가)

  • Kim, Seung-Chan;Kyung, Ki-Uk;Sohn, Jin-Hun;Kwon, Dong-Soo
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.10
    • /
    • pp.900-909
    • /
    • 2007
  • This paper describes an experiment on the evaluation of human sensibility by monitoring responses to changes In the frequency and amplitude of a tactile display system. Preliminary tasks were performed to obtain effective adjectives concerning texture perception. The number of collected adjectives was originally 33. This number of adjectives was reduced to 14 by a suitability survey that asked whether an adjective is suitable for expressing a texture feeling. Finally after performing a semantic similarity evaluation, the number of adjectives was further reduced to ten and these ten were used in the main experiment. In the main experiment, selected sandpaper types and 15 selected combinations of frequencies and amplitudes of a tactile display were utilized to quantitatively evaluate the ten adjectives using a bipolar seven-point scale. The data show that a relationship exists between the independent variables(frequency, amplitude, and grit site) and the dependent variable(perceived texture). That is, the change of frequency and amplitude is directly related to perceived roughness or essential elements of human tactile sensitivity found in the preliminary experiment.

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

COMPARATIVE EVALUATION OF LIGHT-CURED COMPOSITE RESINS BASED ON VITA SHADE BY SPECTROCOLORIMETER (분광색채계측기를 이용한 Vita Shade 광중합형 복합레진의 색상 비교)

  • Cho, Kyoung-Yee;Hwang, In-Nam;Choi, Hong-Ran;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.424-432
    • /
    • 1998
  • To get a satisfactory result in the composite resin restorations, it is necessary to choose correct shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guide or Bioform shade guide, but color differences might be expected even using the same shade in various materials. In this study, five kinds of light-cured composite resins with A2 and B3 shade were used to measure and compare the color each other while one porcelain served as a control. All composite resins (Spectrum TPH (SP), VeridonFil- Photo (VE), Z100 (Z100), Charisma (CH), Prodigy (PRO)) were filled in to the metal mold (12 mm diameter, 2 mm depth), followed by compression, polymerization and polishing with wet sandpaper. The specimens of porcelain were fabricated by using the refractory mold for porcelain. After 24 hours, the specimens were placed on the spectrocolorimeter and spectral reflectance were measured under CIE illuminant D65. After measuring the values of $L^*$, $a^*$, $b^*$ and ${\Delta}E^*$, following results were obtained; 1. The $L^*$, $a^*$ and $b^*$ values of both shade of porcelain specimens showed significantly higher than those of resin specimens(p<0.05). 2. In comparing the resin specimens of the A2 shade, differences were significant except $L^*$ values of SP-CH and PRO-VE, $a^*$ values of the VE-SP and $b^*$ values of the VE-Z100 and SP-PRO(p<0.05), 3. In comparing the resin specimens of the B3 shade, differences were significant except $L^*$ values of PRO-SP, $a^*$ values of the SP-PRO and Z100-VE and b* values of the PRO-SP(p<0.05). 4. In comparing the resin specimens of the A2 shade, color differences between materials (${\Delta}E^*$) showed the lowest value of 1.66, and the highest was 5.16. ${\Delta}E^*$ values of the materials of VE-PRO, CH-PRO, SP-PRO, SP-Z100 and SP-CH were lower than 3.3. 5. In comparing the resin specimens of the B3 shade, the lowest value of the ${\Delta}E^*$ was 0.57 and the highest was 5.92. ${\Delta}E^*$ values of Z100-CH and SP-PRO were lower than 3.3. The present study revealed there was perceptible color difference between materials even if they have the same designated shade based on Vita shade guide. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

  • PDF

REGIONAL MICRO-SHEAR BOND STRENGTH TO DENTIN:EFFECTS OF DENTINAL HARDNESS, POSITION, AND REMAINING DENTIN THICKNESS (상아질의 경도, 위치 및 잔존 상아질 후경이 상아질에 대한 부위별 미세 전단결합강도에 미치는 영향)

  • Hwang, Seon-Seong;Im, Mi-Kyung;Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.401-412
    • /
    • 1998
  • The aim of this study was to measure the regional micro-shear bond strength of dentin bonding agents to dentin, and to investigate the relationship between the micro-shear bond strength and two dentinal characteristics ; Vickers hardness and remaining dentin thickness. Twenty-four freshly extracted, noncarious human molars were selected for this study. The materials tested in this study consisted of two commercially available dentin bonding agents (MAC-BOND, ONE-STEP) and two restorative light-cured composite resins (AELITEFIL, Z100). The occlusal or side surface of tooth crown was sectioned to expose dentin, and the exposed surface was finally polished with # 600 sandpaper. Four groups of application methods were used combining the filling materials and the dentin bonding agents. The composite resin-attached tooth specimens were embeded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of 1mm $\times$ 1mm. Nine specimens were obtained from each tooth. The cut specimens were divided into three groups depending on the position of the dentin bonding surface. The micro-shear bond strength, remaining dentin thickness, and dentinal hardness were measured. Experimental results were then statistically analyzed with ANOVA. t-test, Scheffe test, and regression analysis. From this experiment, the following results were obtained : 1. In the case of occlusal surface bonding, the pooled micro-shear bond strength of ONST-AELIT group (16.62 MPa) was significantly higher than that of MACB-AELIT group (9.91 MPa) (p<0.05). However, there was no significant difference in the micro-shear bond strength depending on the dentin position (p>0.05). 2. In the case of side surface bonding of crown, the pooled micro-shear bond strength of four different bonding groups was not significantly different among each other (p>0.05). However, in three of the test groups (ONST-AELIT, MACB-Z100, ONST-Z100), the micro-shear bond strength to the lower 1/3(III) position was significantly lower than that to middle 1/3(II) position of surface (p<0.05). 3. In the ONST-AELIT bonding group, the pooled micro-shear bond strength to the occlusal surface was significantly lower than that to the side surface of crown (p<0.05). 4. There was no significant correlation between the micro-shear bond strength and dentin hardness / remaining dentin thickness (p>0.05).

  • PDF

Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration (골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구)

  • Hwang, Gab-Woon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.145-151
    • /
    • 2021
  • This study aimed to investigate the efficient conduct of HA coating on Ti Gr4 for the practical use of medical device. Ti Gr4 alloy specimens measuring 𝜱 25mm × 1mm were sprayed with hydroxyapatite using thermal spray according to ASTM F1185-88. The surface was evaluated at #120, #400, #1,000 sandpaper and barrel finishing. Each coating properties was analyzed using SEM, UTS 20,000psi cap. and in vitro cytotoxicity. Surface morphology consists of well molten particles with very little resolidified or unmolten areas. The average Ca/P ratio is 1.74 which is in good agreement with theoretical value of 1.67. The average roughness Ra is very representative of roughness of specimen. The coatings are dense and well adhered to the substrate. The average bond strength was 61.74 MPa with a standard deviation of 4.06 which indicates fairly reliable results for ASTM 633 type tests. Variations in results from jig design, epoxy used, crosshead speeds etc. in vitro cytotoxicity result had a Grade 3. The results of the study are expected to be helpful in osseointegration and plasma-spray HA coated Ti Gr4 are more satisfactory in HA coating thickness elevation which is preferable to any other system.

Evaluation of Surface Condition and Food Solution on the Color Stability of Dental Restoration Materials (표면 상태와 용액에 따른 치과용 수복재료의 색안정도 평가)

  • Woo, Hee-Sun;Kim, Hyo-Jin;Jun, Soo-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.4
    • /
    • pp.359-367
    • /
    • 2019
  • For this study, specimens were prepared using five types of composite resin and resin-reinforced glass ionomer Fuji II LC, and 29 days precipitation was done in four kinds of solution, which were soy sauce, gochujang, wine, and distilled water. Ten specimens for each coloring sample were divided into two groups, one those surfaces was polyester film and the other with 1200-grit abrasive paper, and 20 specimens per materials. Color change (${\Delta}{\ast}ab$) in the colored specimens is measured in 2days, 7days, 14days and 29days using spectrophotometer (CM-2600d, Konica, Minolta, Ramsey, NJ). All values were considered significant when P<0.05. 1. Each material is discolored over time under the influence of different storage solutions. 2. In soy source, among the specimens polished with polyester film, color change was observed in resin-modified glass ionomer Fuji II LC, prodigy and compomer F-2000 on day 2. Meanwhile, Fuji II LC showed noticeable color change in specimens prepared with 1200-grit sandpaper on day 2, which was followed by flowable resin on day 7. 3. On day 2, there was a color change with the specimens of flowable resin, resin-modified glass ionomer Fuji II LC and Prodigy among the hybrid specimen in the groups of polyester film in gochujang.

Variation of Earth Pressure Acting on the Cut-and-Cover Tunnel Lining due to Geotextile Mat Reinforcement (지오텍스타일 매트의 설치에 의한 개착식 터널 라이닝에 작용하는 토압의 변화)

  • Bautista, F.E.;Park, Lee-Keun;Im, Jong-Chul;Joo, In-Gon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.3
    • /
    • pp.25-40
    • /
    • 2007
  • Excessive earth pressure is one of the major mechanical factors in the deformation and damage of Cut-and-Cover Tunnel lining in shallow tunnels and portals of mountain tunnels (Kim, 2000). Excessive earth pressure may be attributed to insufficient compaction and consolidation of backfill material due to self-weight, precipitation and vibration caused by traffic (Komiya et al., 2000; Taylor et al., 1984; Yoo, 1997). Even though there were a lot of tests performed to determine the earth pressure acting on the tunnel lining, unfortunately there were almost no case histories of studies performed to determine remedial measures that reduce differential settlement and excessive earth pressure. In this study the installation of geotextile mat was selected to reduce the differential settlement and excessive earth pressure acting on the cut-and-cover tunnel lining. In order to determine settlement and earth pressure reduction effect (reinforcement effect) of geotextile mat reinforcement, laboratory tunnel model tests were performed. This study was limited to the modeling of rigid circular cut-and-cover tunnel constructed at a depth of $1.0D\sim1.5D$ in loose sandy ground and subjected to a vibration frequency of 100 Hz. Model tests with varying soil cover, mat reinforcement scheme and slope roughness were performed to determine the most effective mat reinforcement scheme. Slope roughness was adjusted by attaching sandpaper #100, #400 and acetate on the cut slope surface. Mat reinforcement effect of each mat reinforcement scheme were presented by the comparison of earth pressure obtained from the unreinforced and mat reinforced model tests. Soil settlement reduction was analyzed and presented using the Picture Analysis Method (Park, 2003).

THE INFLUENCE OF THE VITAL BLEACHING AGENTS ON TRANSLUCENCY OF THE BOVINE ENAMEL (생활치 미백제가 우치 법랑질의 투명도에 미치는 영향)

  • Kim, Dong-Jun;Kim, Young-Ju;Kim, Hak-Geun;Park, Eun-Jong;Seo, Eun-Ju;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.178-183
    • /
    • 2005
  • This study was done to evaluate whether vital bleaching agents could influence on the translucency of the bovine enamel. The anterior bovine teeth that were extracted one day before and without any gross discoloration were obtained and then were preserved in physiologic saline. 6 mm cylindrical tooth specimens were fabricated with diamond puncher perpendicularly on labial surface of bovine tooth. After embedded in transparent acrylic resin with labial surface being exposed, they were cut to a thickness of 1.2 mm with low speed diamond saw (Isomat, Buehler Co., Lake Bluff, IL, USA). They were smoothly ground to 1 mm thickness of enamel with sandpaper. 24 specimens were randomly divided into 3 groups and control group respectively. Opalescence (10% carbamide peroxide, Ultradent, South Jordan, USA), Rembrandt (10% carbamide peroxide, DenMat, USA) and Opalescence F (15% carbamide peroxide with fluoride, Ultradent, USA) were applied on labial sides of the bovine enamel for 7 days (bleaching agents were reapplied every 24 hours) and the opposite surface was contacted to cotton that soaked in distilled water. The control group was soaked in distilled water. Three stimulus value X, Y and Z were evaluated with colorimeter (Color ' Color Differencerneter, Model TC-6FX, Tokyo Denshoku Co., Japan) on the labial surface of all specimen three times on white and black background plate before the bleaching agents were applied and on 3rd, 5th and 7th day after applied. The degree of translucency was normally assessed by measuring the inverse property, opacity (contrast ratio). 10% Opalescence, 15% Opalescence-F, and control group showed no significant variation in the translucency of bovine enamel, However Rembrandt decreased the translucency of it (p < 0.01).