• Title/Summary/Keyword: sand to cement ratio

Search Result 236, Processing Time 0.028 seconds

Assement of setting times of cement mortar with different ratio of sand using Electro-mechanical impedance sensing technique (EMI 센싱 기법을 이용한 잔골재 혼합비에 따른 모르타르의 응결특성)

  • Lee, Jun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.51-52
    • /
    • 2022
  • The electro-mechanical impedance(EMI) behavior of piezoelectric sensor embedded in cement mortar was investigated to assess the setting times. EMI signal was continuously measured for 12 hours by the PZT sensor embedded in cement mortar with different ratio of sand. As a result, the setting times by the penetration resistance test were accelerated as the sand ratio increased. However, the setting times by EMI sensing technique were delayed as the sand ratio increased.

  • PDF

An Experimental Study on the Fundamental Characteristics of Antiwashout Underwater Concrete with Variation of Water-cement Ratio (W/C 변화에 따른 수중불분리 콘크리트의 기초특성에 관한 실험적 연구)

  • 김명식;어영선;윤재범;이상명
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.21-29
    • /
    • 1999
  • In this study, an experiment was performed to analyze the influence of water-cement ratio on the fundamental characteristics of antiwashout underwater concrete using blended sand (sea sand:river sand = 1:1). The water-cement ratio (45%, 50%, 55%, 60%), andtiwashout underwater agent contents (0.82%, 1.00%, 1.14% of water contents per unit volume of concrete), and superplasticizer contents (1.5%, 2.0%, 2.5% of cement contents per unit volume of concrete) were chosen as the experimental parameters. The experimental results show that the underwater segregation resistance, unit weight of hardening concrete and compressive strength were increased as the water-cement ratio decreased and as the antiwashout underwater agent contents increased. On the other hand, the flowability(slump flow) was increased to the 55% of the increase of water-cement ratio, however, it was decreased at the ratio of 60%. From this study, the antiwashout underwater concrete can potentially be used as a materials underwater work of ocean if the water-cement ratio and chemical admixture contents for the suitable balance between cost and performance are properly selected.

An experimental investigation on dynamic properties of various grouted sands

  • Hsiao, Darn-Horng;Phan, Vu To-Anh;Huang, Chi-Chang
    • Geomechanics and Engineering
    • /
    • v.10 no.1
    • /
    • pp.77-94
    • /
    • 2016
  • Cyclic triaxial and resonant column tests were conducted to understand the beneficial effects of various grouted sands on liquefaction resistance and dynamic properties. The test procedures were performed on a variety of grouted sands, such as silicate-grouted sand, silicate-cement grouted sand and cement-grouted sand. For each type of grout, sand specimen was mixed with a 3.5% and 5% grout by volume. The specimens were tested at a curing age of 3, 7, 28 and 91 days, and the results of the cyclic stress ratio, the maximum shear modulus and the damping ratio were obtained during the testing program. The influence of important parameters, including the type of grout, grout content, shear strain, confining pressure, and curing age, were investigated. Results indicated that sodium silicate grout does not improve the liquefaction resistance and shear modulus; however, silicate-cement and cement grout remarkably increased the liquefaction resistance and shear modulus. Shear modulus decreased and damping ratio increased with an increase in the amplitude of shear strain. The effect of confining pressure on clean sand and sodium silicate grouted sand was found to be insignificant. Furthermore, a nonlinear regression analysis was used to prove the agreement of the shear modulus-shear strain relation presented by the hyperbolic law for different grouted sands, and the coefficients of determination, $R^2$, were nearly greater than 0.984.

Effects of cement type and sand to cement ratio on the properties of PSC grout (시멘트 종류 및 잔골재 시멘트 비율이 PSC 구조물용 그라우트의 기본 물성에 미치는 영향)

  • Park, Gi-Joon;Moon, Do-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4644-4652
    • /
    • 2014
  • This study examined the effects of the cement type and sand to cement ratio on the properties of grout for offshore PSC structures. Types I and III cement were used and the sand to cement ratio was varied from 0.5 to 1.5. When type I cement was used, considerable bleeding occurred on the all S/C after 3 hours and 20 hours. When type III cement was used, bleeding was reduced but the flowability decreased. A comparison of a superplasticizer containing naphthalene with that containing polycarboxylate showed that the problem of flowability could be solved using polycarboxylate.

Properties of the Concrete using the Waste Foundry Sand Powder by Cement Replacement (폐주물사 미분말을 시멘트 대체재료로 사용한 콘크리트의 특성)

  • Woo Jong-Kwon;Ban Joo-Hwan;Ryu Hyun-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.57-61
    • /
    • 2006
  • Waste foundry sand of industrial waste which is happening by vast quantity according to fast development of industry has much the occurrence amount and processing method is depended on reclamation, and is using by fine aggregate for construction by recycling method among others. In this research Waste foundry sand powder into cement replace fare use possibility availability judge wish to Slump and air content decreased the replacement ratio increases by concrete special quality that do not harden according to experiment result, and unit capacity mass and bleeding increased the replacement ratio increases. Hardening concrete intensity special quality displayed strength improvement to replacement ratio 20%, and tendency that watertightness increases most in replacement ratio loft in watertight property appear. Considering the strength and watertight properties, the adequate usage of waste foundry sand powder is the 10% of replacement ratio.

  • PDF

Experimental study on the strength behavior of cement-stabilized sand with recovered carbon black

  • Chhun, Kean Thai;Choo, Hyunwook;Kaothon, Panyabot;Yune, Chan-Young
    • Geomechanics and Engineering
    • /
    • v.23 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Soil-cement stabilization is a type of ground improvement method which has been used to improve the engineering properties of soil. The unconfined compression test is the commonly used method to evaluate the quality of the stabilized soil due to its simplicity, reliability, rapidity and cost-effectiveness. The main objective of this study was to evaluate the effect of recovered carbon black (rCB) on the strength characteristic of cement-stabilized sand. Various rCB contents and water to cement ratios (w/c) were examined. The unconfined compression test on stabilized sand with different curing times was also conducted for a reconstituted specimen. From the test result, it was found that the compressive strength of cement-stabilized sand increased with the increase of the rCB content up to 3% and the curing time and with the decrease of the w/c ratio, showing that the optimum rCB concentration of the tested stabilized sand was around 3%. In addition, a prediction equation was suggested in this study for cement-stabilized sand with rCB as a function of the w/c ratio and rCB concentration at 14 and 28 days of curing.

Compressive strength characteristics of cement treated sand prepared by static compaction method

  • Yilmaz, Yuksel;Cetin, Bora;Kahnemouei, Vahid Barzegari
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.935-948
    • /
    • 2017
  • An experimental program was conducted to investigate the effects of the static compaction pressure, cement content, water/cement ratio, and curing time on unconfined compressive strength (UCS) of the cement treated sand. UCS were conducted on samples prepared with 4 different cement/sand ratios and were compacted under the lowest and highest static pressures (8 MPa and 40 MPa). Each sample was cured for 7 and 28 days to observe the impact of curing time on UCS of cement treated samples. Results of the study showed the unconfined compressive strength of sand increased as the cement content (5% to 10%) of the cement-sand mixture and compaction pressure (8 MPa to 40 MPa) increased. UCS of sand soil increased 30% to 800% when cement content was increased from 2.5% to 10%. Impact of compaction pressure on UCS decreased with a reduction in cement contents. On the other hand, it was observed that as the water content the cement-sand mixture increased, the unconfined compressive strength showed tendency to decrease regardless of compaction pressure and cement content. When the curing time was extended from 7 days to 28 days, the unconfined compressive strengths of almost all the samples increased approximately by 2 or 3 times.

Unconfined Compressive Strength of Cemented Sand Reinforced with Short Fibers (단섬유를 사용한 시멘트 혼합토의 일축압축강도 특성)

  • Park, Sung-Sik;Kim, Young-Su;Choi, Sun-Gyu;Shin, Shi-Eon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.213-220
    • /
    • 2008
  • A study on cemented sand reinforced with short fibers was carried out to improve its unconfined compressive strength and brittle behavior. Nak-dong River sand was mixed with Portland cement and polyvinyl alcohol (PVA) fibers. A PVA fiber widely used for concrete reinforcement is randomly distributed into cemented sand. Nak-dong River sand, cement and fibers with optimum water content were compacted in 5 layers and then cured for 7 days. The effect of fiber reinforcement rather than cementation was emphasized by using a small amount of cement. Weakly cemented sand with a cement/sand ratio less than 8% was fiber-reinforced with different fiber ratios and tested for unconfined compression tests. The effect of fiber ratio and cement ratio on unconfined compressive strength was investigated. Fiber-reinforced cemented sand with 2% cement ratio showed up to six times strength to non-reinforced cemented sand. Because of ductile behavior of fiber-reinforced specimens, an axial strain at peak stress of specimens with 2% cement ratio increases up to 7% as a fiber ratio increases. The effect of 1% fiber addition into 2% cemented sand on friction angle and cohesion was analyzed separately. When the fiber reinforcement is related to friction angle increase, the 8% of applied stress transferred to 1% fibers within specimens.

Properties of Flowable High-volume Fly Ash-Cement Composites (다량의 플라이애쉬를 사용한 유동성 시멘트복합체의 특성)

  • 원종필;신유길;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.105-110
    • /
    • 1998
  • The purpose of this was to examine the used of fly ash as a type of construction material. In this paper the results from a recent study on development of a cement composite utilizing relatively large amount of fly ash are presented. The flowable fly ash-cement sand composite was investigated for strength and flowability characteristics. The independent variable considered were: fly-ash content, sand content, and ratio of water to cementitious materials. Results of this study show that high volume fly-ash composite can be proportioned to obtain 10~15kg/$\textrm{cm}^2$ compressive strength at 28 days. For applications requiring strength between 10kg/$\textrm{cm}^2$ and 15kg/$\textrm{cm}^2$, the mixture with fly ash-cement ratio of 5.6 and sand-cement ratio of 28 with relatively high water content may be used. Slump was held at 25$\pm$1cm for all mixtures produced compressive strength at 28 days were found to range from 5kg/$\textrm{cm}^2$ to 13.7kg/$\textrm{cm}^2$.

  • PDF

Properties of fresh concrete using lime stone powder (석회석미분말을 사용한 굳지않은 콘크리트의 특성)

  • Cho, Il-Ho;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.108-112
    • /
    • 2005
  • In this research, the physical properties of fresh concrete using lime stone powder as a part of cement were investigated. Fresh concrete using lime stone powder was prepared with various lime stone powder replacement($5{\sim}12$ volume %) for cement and the quantities of sand aggregate ratio in concrete were 47.3%, 48.5% and 49.4% of ratio of sand aggregate. The workability, flowing characteristics, air content and bleeding of concrete using lime stone powder were tested and the results were compared with those of ordinary portland cement concrete. In the experiment, we acquired satisfactory results at the point of fresh concrete characteristics using lime stone powder within the replacement ratio of $8{\sim}12%$ and the optimum quantity of sand aggregate ratio in concrete was found to be $48.5%{\sim}50%$ of ratio of sand aggregate.

  • PDF