• Title/Summary/Keyword: sand layer thickness

Search Result 71, Processing Time 0.027 seconds

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • v.35 no.1
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.

Free-strain solutions for two-dimensional consolidation with sand blankets under multi-ramp loading

  • Zan Li;Songyu Liu;Cuiwei Fu
    • Geomechanics and Engineering
    • /
    • v.35 no.4
    • /
    • pp.385-393
    • /
    • 2023
  • To analyze the consolidation with horizontal sand drains, the plane strain consolidation model under multi-ramp loading is established, and its corresponding analytical solution is derived by using the separation of variables method. The proposed solution is verified by the field measurement data and finite element results. Then, the effects of the loading mode and stress distribution on consolidation and dissipation of pore pressure are investigated. At the same time, the influence of hydraulic conductivity and thickness of sand blankets on soil consolidation are also analyzed. The results show that the loading mode has a significant effect on both the soil consolidation rate and generation-dissipation process of pore water pressure. In contrast, the influence of stress distribution on pore pressure dissipation is obvious, while its influence on soil consolidation rate is negligible. To guarantee the fully drained condition of the sand blanket, the ratio of hydraulic conductivity of the sand blanket to that of clay layer kd/kv should range from 1.0×104 to 1.0×106 with soil width varying from 100 m to 1000 m. A larger soil width correspondingly needs a greater value of kd/kv to make sure that the pore water can flow through the sand blanket smoothly with little resistance. When the soil width is relatively small (e.g., less than 100 m), the effect of thickness of the sand blanket on soil consolidation is insignificant. And its influence appears obvious gradually with the increase of the soil width.

A Study On the Sand Wear Resistance and Formation Behavior of Boride Layer Formed on Ni-Cr-Mo Steel by Plasma Paste Boronizing Treatment (Plasma Paste Boronizing법에 의한 Ni-Cr-Mo강의 붕화물층 생성거동과 내 토사마모특성에 관한 특성)

  • Cho J. H;Park H. K;Son K. S;Yoon J. H;Kim H. S;Kim C. G
    • Korean Journal of Materials Research
    • /
    • v.14 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • The surface property and formation behavior of a boride layer formed on Ni-Cr-Mo steel in a plasma paste boronizing treatment were investigated. The plasma paste boronizing treatment was carried out at 973~1273 K for 1-7 hrs under the gas ratio of Ar:H$_2$ (2:1). The thickness of the boride layer increased with increasing temperature and time in the boronizing treatment. The cross-section of the boride layer was a tooth structure and the hardness was Hv 2000~2500. XRD analysis revealed that the compound was identified as FeB, $Fe_2$B, and mixed phase of FeB/$Fe_2$B in the boride layer formed at 973~1073 K, 1173K, and 1273K, respectively. The Ni-Cr-Mo alloy boronized at 1173-1273 K showed the best excellent wear resistance against the sand. As a results of corrosion test in 1 M $H_2$$SO_4$ solution, $Fe_2$B formed on the matrix alloy exhibited higher corrosion resistance than FeB.

An Experimental Study on Vacuum Drying of Water-Saturated Porous Media (함수다공질층의 진공건조에 관한 실험적 연구 (Ⅰ))

  • Park, Hyeong-Jin;Kim, Gyeong-Geun;Kim, Myeong-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.5
    • /
    • pp.68-75
    • /
    • 1996
  • The vacuum drying characteristics of water-saturated porous media were studied experimentally. The water-saturated porous media, water-saturated sand layer, was heated by the isothermal bottom wall of the rectangular vessel. The vacuum drying rate and temperature distribution of the sand layer were measured and calculated under a variety of conditions of heated wall temperature, vacuum rate, and thickness of the test material. It was found that the drying rate due to the heat and mass teansfer is greatly influenced by the heated wall temperature, vacuum rate, and thickness of the test material.

  • PDF

Use of large-scale shake table tests to assess the seismic response of a tunnel embedded in compacted sand

  • Zhou, Hao;Qin, Xiaoyang;Wang, Xinghua;Liang, Yan
    • Earthquakes and Structures
    • /
    • v.15 no.6
    • /
    • pp.655-665
    • /
    • 2018
  • Shield tunnels are widely used throughout the world. However, their seismic performance has not been well studied. This paper focuses on the seismic response of a large scale model tunnel in compacted sand. A 9.3 m long, 3.7 m wide and 2.5 m high rigid box was filled with sand so as to simulate the sandy soil surrounding the tunnel. The setup was excited on a large-scale shake table. The model tunnel used was a 1:8 scaled model with a cross-sectional diameter of 900 mm. The effective shock absorbing layer (SAL) on the seismic response of the model tunnel was also investigated. The thickness of the tunnel lining is 60 mm. The earthquake motion recorded from the Kobe earthquake waves was used. The ground motions were scaled to have the same peak accelerations. A total of three peak accelerations were considered (i.e., 0.1 g, 0.2 g and 0.4 g). During the tests, the strain, acceleration and soil pressure on the surface of the tunnel were measured. In order to investigate the effect of shock absorbing layer on the dynamic response of the sand- tunnel system, two tunnel models were set up, one with and one without the shock absorbing layer of foam board were used. The results shows the longitudinal direction acceleration of the model tunnel with a shock absorbing layer were lower than those of model tunnel without the shock absorbing layer, Which indicates that the shock absorbing layer has a beneficial effect on the acceleration reduction. In addition, the shock absorbing layer has influence on the hoop strain and earth pressure of the model tunnel, this the effect of shock absorbing layer to the model tunnel will be discussed in the paper.

A Study on the Characteristics of Green Design and Construction of Golf Courses in Korea (한국의 골프 코스 그린의 설계 및 시공 특성에 관한 연구)

  • 이상재;허근영
    • Asian Journal of Turfgrass Science
    • /
    • v.13 no.4
    • /
    • pp.181-190
    • /
    • 1999
  • This study was carried out to survey green system, area, green slope, green turfgrass variety, green section, and particle size of green construction materials, and to investigate and evaluate the characteristics of Design and Construction in Korean golf course green for improving the quality of Korean golf course into that of the international golf course held international tournament. The results were as follows. 1. The greens of 129 Korean golf courses consisted of 2(two) green system and 1(one) green system. 2(two) green system was 50.8%, 1(one) green system was 40.7%, and 1+2 green system was 8.5% of them. 2. In 48 Korean golf courses, the green area of 2(two) green system was mostly 400~$600\m^2$(56.5%) and the green area of 1(one) green system was mostly 600~$800\m^2$(47.8%). In 48 Korean golf courses, 1.5~3% green slope appeared the highest frequency(50.0%) and the next was 3~5%(29.4%). 3. Penncross variety was the highest frequency(71.2%). The next was mixed variety (Penncross+Crenshaw, Penn A-1, Pennlinks, or Penneagle/SR 1020+SR 1019) and the frequency of mixed variety was 7.6%. 4. In 48 Korean golf courses, 70~80cm total thickness of green appeared the highest frequency(36.1%), 10~20cm thickness of green mixed sandy layer appeared the highest frequency(43.6%), and 10~20cm thickness of green coarse sandy layer appeared the highest frequency(55.6%). 0~10cm thickness of green gravel layer appeared the highest frequency(67.6%), 20~30cm thickness of green drain layer appeared the highest frequency(52.8%), and 20~30cm width of green drain layer appeared the highest frequency(44.4%). Below 1mm sand diameter used in green mixed sandy layer appeared the highest frequency(46.2%), below 2mm or over 2mm sand diameter used in green coarse sandy layer appeared the highest frequency(31.4%). 20~40mm coarse gravel diameter used in green gravel layer appeared the highest frequency(43.2%) and 0~20mm fine gravel diameter used in green gravel layer appeared the highest frequency(65.8%). 20~40mm gravel diameter used in green drain layer appeared the highest frequency(64.1%).

  • PDF

A comparative study on damping of finite dry and saturated sand stratum under vertical vibrations

  • Prathap Kumar, M.T.;Ramesh, H.N.;Raghavebdra Rao, M.V.;Asha, M.
    • Geomechanics and Engineering
    • /
    • v.2 no.1
    • /
    • pp.29-44
    • /
    • 2010
  • Vertical vibration tests were conducted using model footings of different size and mass resting on the surface of finite sand layer with different height to width ratios which was underlain by either rigid concrete base, under both dry and saturated condition. The effect of saturation on the damping ratio of finite sand stratum underlain by a rigid base has been verified and compared with the results obtained for the case of finite dry sand stratum underlain by the rigid base. Comparison of results of the experimental study showed that the damping in both the cases is less than 10%. The damping ratio obtained for finite saturated sand stratum is marginally lower than that obtained on finite dry sand stratum at H/B ratio of 0.5. The difference between the two cases becomes significant when the H/B ratio increases to 3.0, indicating the significant influence of soil moisture on damping ratio of foundation- soil system with increase in the thickness of the finite sand stratum. Comparison of the predicted damping ratio for a homogeneous sand stratum with the experimental damping ratio obtained corresponding to the height to width ratio of 3.0 of the finite sand stratum underlain by the rigid concrete base indicates a significant reduction in damping ratio of the foundation-soil system for both the cases.

Evaluation of Discharge Capacity of Upper Sand Deposit at the Nakdong River Estuary (낙동강 하구 상부퇴적사질토의 통수능 평가)

  • Jeong, Jin-Yeong;Kim, Tae-Hyung;Im, Eun-Sang;Hwang, Woong-Ki;Kim, Gyu-Jong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.109-119
    • /
    • 2017
  • In this research, it was investigated that whether the upper sand deposited in Nakdong River Estuary Delta region has the role of horizontal drains like sand mat. The results from tests for particle size distribution and permeability of the upper sand deposit did not meet completely the criteria for the horizontal drain material. Thus, numerical analysis has been conducted additionally. Numerical analyses of consolidation of soft soils with upper layer of sand deposit are conducted in both the sand mat with a thickness of 1m and the upper sand deposit with 1, 2, 3, and 4 m of thickness and their results are compared. As the results of numerical analysis, the upper sand deposit with a thickness of 2m or more may play the role of horizontal drains similar to a sand mat. If a PVD is installed, the ability of upper sand deposit as horizontal drains is increased. Form this study, it was concluded that the upper sand deposited in Nakdong River Estuary Delta has the role of horizontal drain.

The Experimental Study on the Long-term Creep Settlements of Nam-Hae Sands (남해안 모래의 장기 크리프 침하 특성에 관한 실험적 연구)

  • Park, Eonsang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.9
    • /
    • pp.21-28
    • /
    • 2018
  • In this study, a standard consolidation test (Oedometer) was performed on the relative density of sand in the south coast to evaluate long-term creep settlement characteristics. Experimental results show that the cumulative settlement at the final loading stage decreases as the relative density increases and the variation of the void ratio decreases. As a result of analyzing the settlement rate of long-term creep of sand, creep settlement of 4.7~11.0% occurred depending on relative density with respect to total settlement. The creep parameter, Beta, of Schmertmann et al. (1978) was estimated to be 0.17~0.40 (average 0.21), and it tended to converge to a certain value when the load step becomes more than a certain level. It was found that there is no significant difference in the creep parameter depending on the layer thickness, and it was confirmed that the creep parameter could be applied regardless of the field layer thickness.

Constant Rate of Strain Consolidation Test with Rowe Cell on the Clay with Sand Seam (샌드심이 존재하는 점토에 Rowe Cell를 이용한 일정변형률 압밀시험)

  • Kim, Jae-Hong;Kim, Chan-Kee;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.5
    • /
    • pp.5-13
    • /
    • 2017
  • The sand layer deposited in clay is called a sand seam, which is formed by inflow of sands due to river flooding or slope failure in the middle of sinking and sediment of clay. When the sand seam exists in clay layer, the drainage direction changes from one way to both ways, and the time of consolidation may be reduced. However, it is not clearly proved due to lack of studies of sand seam and currently is not reflected in the design of soft soil improvement. As a fundamental study about sand seam, the oedometer tests and constant rate of strain tests with Rowe cell were conducted on clay specimens with sand seam. For tests, a frozen method was specially designed for making the sand seam. It was concluded that the test results showed the sand seam affects the coefficient of consolidation of clay. If the thickness of sand seam exceeds 0.05 times of specimen height, the sand seam works as drainage layer of pore water horizontally as well as vertically, and consequently the consolidation is accelerated.