• Title/Summary/Keyword: sand filtration

Search Result 174, Processing Time 0.029 seconds

Effect of Advanced Treatment Process for Residual Chlorine Decay and THM Formation in Water Distribution System (고도처리공정이 관로 내 잔류염소 감소 및 THM 생성에 미치는 영향)

  • Lee, Doo-Jin;Kim, Young-Il;Kim, Sung-Su;Lee, Kyung-Hyuk;Park, Hyun-A
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.419-424
    • /
    • 2007
  • According to increase of consumer's desire for clean tap water, advanced treatment processes include with membrane, ozone, and granular activated carbon(GAC) were introduced. In order to evaluate the effect of advanced treatment processes for residual chlorine decay and trihalomethane(THM) formation in water distribution system, dissolved organic matter(DOC) removal of each advanced treatment process was investigated. The residual chlorine decay and THM formation using bottle tests were also evaluated. $UV_{254}$ removal in all advanced treatment was better than DOC removal. Especially, DOC by ozone treated was removed as 4% in contrast with sand filtered water, but $UV_{254}$ was removed about 17%. This result might be due to convert from hydrophobic DOC to hydrophilic DOC by ozonation. Ozone/GAC process was most effective process for DOC removal. The residual chlorine decay constants in treated water by sand filtration, ozonation, GAC adsorption, and ozone/GAC processes were 0.0230, 0.0307, 0.0117 and 0.0098 $hr^{-1}$, respectively. The sand filtered water was produced 81.8 ${\mu}g/L$ of THM after 190 hours of reaction time, as the treated water by ozone, GAC, and Ozone/GAC was less produced 6.0, 26.2, 30.3% in contrast with sand filtered water, respectively. Consequently, the durability of residual chlorine and reduction of THM formation were improved by advanced treatment processes.

Estimation of Unconfined Compressive Strength (UCS) of Microfine Cement Grouted Sand (마이크로 시멘트로 그라우팅 된 모래의 일축압축강도 예측)

  • Nam, Hongyeop;Lee, Woojin;Lee, Changho;Choo, Hyunwook
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.5-15
    • /
    • 2018
  • The unconfined compressive strength (UCS) test through coring is widely used to determine the reinforcement effect of the ground with grouting. However, the UCS test through coring can disturb the ground, is expensive and takes a lot of time to prepare the specimen. In this study, the factors affecting UCS of microfine cement grouted sand are evaluated and an empirical equation of UCS of microfine grouted sand is suggested. It is observed that UCS increases linearly until 28 days, however, the increasing rate of strength decreases sharply after that 28 days. The W/C ratio is dominant factor influencing UCS and UCS increases exponentially with the decrease of water/cement (W/C) ratio. Also, UCS increases linearly with increasing the relative density ranging from 30% to 70% and with decreasing median particle size. However, in case of W/C ratio=1 and K6 ($D_{50}=0.47mm$), UCS is lower than that of K4 ($D_{50}=1.08mm$) and K5 ($D_{50}=0.80mm$) due to filtration effect. Based on the experimental results, the empirical equation of UCS of microfine cement grouted sand can be expressed as the function of median particle size ($D_{50}$), porosity (n) and W/C ratio.

Life Cycle Impacts of Flexible-fiber Deep-bed Filter Compared to Sand-Filter including Coagulation and Sedimentation in Water Treatment Plant

  • Uh, Soo-Gap;Kim, Ji-Won;Han, Ki-Back;Kim, Chang-Won
    • Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Recently a new technology called the flexible-fiber deep-bed filter (FDF) claimed to replace the conventional sand filter including coagulation and sedimentation filter (CSF) processes in the water treatment plant. Therefore the life cycle assessment (LCA) approach was applied for evaluating the life cycle impacts of FDF compared with those of CSF. The used LCA softwares were the Simapro 6 and PASS and their life cycle impact assessment (LCIA) methodologies were the Eco-indicator 99 and the Korean Eco-indicator, respectively. The goal of this LCA was to identify environmental loads of CSF and FDF from raw material to disposal stages. The scopes of the systems have been determined based on the experiences of existing CSF and FDF. The function was to remove suspended solids by filtration and the functional unit was $1\;m^3$/day. Both systems showed that most environmental impacts were occurred during the operation stage. To reduce the environmental impacts the coagulants and electricity consumptions need to be cut down. If the CSF was replaced with the FDF, the environmental impacts would be reduced in most of the impact categories. The LCA results of Korean Eco-indicator and Eco- indicator99 were quite different from each other due to the indwelling differences such as category indicators, impact categories, characterization factors, normalization values and weighting factors. This study showed that the life cycle assessment could be a valuable tool for evaluating the environmental impact of the new technology which was introduced in water treatment process.

Evaluation of Catchbasin for Increasing Interception Capability of Stormwater Runoff (강우유출수 차집능력 증대형 빗물받이의 성능 평가)

  • Han, Sangjong;Shin, Hyunjun;Hwang, Hwankook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.567-575
    • /
    • 2017
  • It is not cost effective to raise the density of catch basins in preparation for heavy rainfall in terms of construction and maintenance. Our researchers have developed the new catch basin for increasing interception capacity of runoff with internal filtration structure. To compare interception capacity of an existing catch basin with the invented catch basin, a hydraulic experiment device with 4% of road gradients and 0.2% of road gradients was constructed. For runoff conditions of 4.4 l/s, 6.7 l/s and 10.4 l/s, capability of runoff and separation capability of debris (sand and leaves) were evaluated. As the main experimental results, the effectiveness of the developed catch basin has been verified with an increase in interception rate of approximately 22% for the runoff of 6.7 l/s as heavy rainfall. However, the results of invented catch basin showed only 4.5% of settlement rate of debris regarding sand. Therefore, the authors proposed an improved tilted screen structure additionally. After reviewing the performance of improved catch basin, application of the invented catch basin is expected to drain runoff effectively when it is applied to the faulty road drainage section.

Effects of Media Breakage on Infiltration Characteristics in Stormwater Management System (강우유출수 처리시설 침투특성에 대한 필터여재 파쇄의 영향)

  • Segismundo, Ezequiel Q.;Koo, Bon-Hong;Kim, Lee-Hyung;Lee, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.2
    • /
    • pp.31-41
    • /
    • 2016
  • For sand and zeolite filter media in stormwater BMPs, media breakage effects on infiltration were investigated. Compaction effort and infiltration force were mainly examined for breakage sources. The 1-D column infiltration tests for un-compacted and compacted media filters were conducted to investigate the breakage effect on infiltration. As a result, the following findings were deduced: 1) particle breakage due to filtration forces was found to be relatively minimal; 2) un-compacted media had lesser amount of crushed particles and permeability fluctuations compared to compacted media; 3) even without the presence of suspended solids in the influent, reduction in permeability was found, which resulted from rearrangement and re-entrainment of media particle itself; 4) only media particle breakage resistance is considered, sand was revealed to have better performance compared to zeolite media.

Recent Techniques for Design and Construction of CFRD (CFRD의 최근 설계ㆍ시공기술 동향)

  • Park Dong-Soon;Kim Hyoung-Soo;Lim Jeong-Yeul
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.77-86
    • /
    • 2005
  • CFRD(Concrete Faced Rockfill Dam) is in widespread use because this type of dam has superior characteristics in structural, material aspects comparing with earth cored rockfill dam. On this paper, up-to-date re-searches and techniques are summed up to be available for future needs in design and construction of CFRD. For example, such items as embankment using weak rock, experience of sand-gravel fill CFRD, connecting slab applied between plinth and face slab, raising experience of old dm, inverse filtration problem, environmental friendly zone, thickness and reinforcing of face slab, alluvial foundation treatment, and curb element method, are summarized for understanding of related engineers.

A study on induced polarization characteristics of sand and clay for alluvium investigation (충적층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.179-184
    • /
    • 2008
  • Silt or clay alluvium fully saturated with water generally shows low resistivity. Sometimes it is believe that the low resistivity layer is considered as good aquifer but this makes problems in the development of groundwater. To overcome this problem, we adopted induced-polarization(IP) method with resistivity method. Laboratory experiments and resistivity/IP field surveys with non-polarization electrodes were conducted for the study. Laboratory experiments shows that the increase of clay contents in the sample mixed with sand and clay give low resistivity and high chargeability. We used this experiment results in the interpretation of resistivity/IP field data which were obtained in riverbank filtration. Finally, the layer which has low resistivity and chargeabilty would be regarded as a good aquifer for the development of groundwater intake.

  • PDF

Study on Removal of Cesium in Water Treatment System (물속의 방사성핵종(세슘) 제거율 연구)

  • Jeong, Gwanjo;Son, Boyoung;Ahn, Chihwa;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • This study investigated the removal of a radioactive cesium ($Cs^+$) in the water at the water treatment processes. Since cesium is mostly present as the $Cs^+$ ion state in water, it is not removed by sand filtration, and coagulation with polyaluminum chloride (PACl), powdered activated carbon (PAC) and mixture of PACl and PAC. However, it is known that the removal rate of cesium increases as the turbidity increases in raw water. As the turbidity was adjusted by 74 NTU and 103 NTU using the surrounding solids near G-water intake and yellow soils, removal rate of cesium was about 56% and 51%, respectively. In case of a GAC filtration with supernatants after jar-mixing/setting was conducted, 80% of cesium is approximately eliminated. The experimental results show that it is efficient to get rid of cesium when the turbidity of the raw water is more than 80 NTU. In case of a GAC filtration, about 60% of cesium is removed and it is considered by the effect of adsorption. Cesium is not eliminated by microfiltration membrane while about 75% of cesium is removed by reverse osmosis.

A Study on Removal of Disinfection By-products in High Concentration Powdered Activated Carbon Membrane Bio-reactor Process for Advanced Water Treatment (고도정수처리를 위한 HCPAC-MBR 공정에서의 소독부산물 저감에 관한 연구)

  • Lee, Song-Hee;Jang, Sung-Woo;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • This study was conducted to evaluate the performance of a membrane bioreactor filled with high concentration of powdered activated carbon (HCPAC-MBR) to reduce DBPs at the drinking water treatment. The pilot system was installed after the rapid sand filtration process whose plant was the conventional treatment process. The removal efficiencies of DBPs were measured during pilot operation period of 2 years. HAA and THM removal rates could be maintained around 80~90% without any troubles and then tremendous reduction of HAA and THM reactivity were observed more than 52%. The average removal rate of HAA formation potential (FP) and THM formation potential (FP) were 70.5% and 67.6% respectively. It is clear that the PAC membrane bioreactor is highly applicable for advanced water treatment to control DBPs.

Evaluation of Haloacetic Acid Formation Potential in Drinking Water Treatment Process by Fraction Technique (정수처리 공정에서 용존 유기물질 분류에 의한 haloacetic acid 생성능 평가)

  • Son, Hee-Jong;Hwang, Young-Do;Ryu, Dong-Choon;Jung, Chul-Woo;Lee, Gun;Son, Hyeng-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1655-1662
    • /
    • 2014
  • A comprehensive fractionation technique was applied to a set of water samples obtained along drinking water treatment process with ozonation and biological activated carbon (BAC) process to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that coagulation-sedimentation-sand filtration treatment showed limited ability to remove hydrophilic fraction (28%), while removal of hydrophobic and transphilic fraction were 57% and 40%, respectively. And ozonation and BAC treatment showed limited ability to remove hydrophobic fractions (6%), while removal of hydrophilic and transphilic fractions were 25% and 18%. The haloacetic acid formation potential (HAAFP)/dissolved organic carbon (DOC) of hydrophilic fraction was the highest along the treatment train and HAAFP/DOC of hydrophilic fraction was higher than hydrophobic and transphilic fraction as 23%~30%, because of better removal for hydrophobic fraction both in concentration and reactivity.