• Title/Summary/Keyword: sample correlation

Search Result 2,438, Processing Time 0.03 seconds

An elaboration on sample size determination for correlations based on effect sizes and confidence interval width: a guide for researchers

  • Mohamad Adam Bujang
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.2
    • /
    • pp.21.1-21.8
    • /
    • 2024
  • Objectives: This paper aims to serve as a useful guide for sample size determination for various correlation analyses that are based on effect sizes and confidence interval width. Materials and Methods: Sample size determinations are calculated for Pearson's correlation, Spearman's rank correlation, and Kendall's Tau-b correlation. Examples of sample size statements and their justification are also included. Results: Using the same effect sizes, there are differences between the sample size determination of the 3 statistical tests. Based on an empirical calculation, a minimum sample size of 149 is usually adequate for performing both parametric and non-parametric correlation analysis to determine at least a moderate to an excellent degree of correlation with acceptable confidence interval width. Conclusions: Determining data assumption(s) is one of the challenges to offering a valid technique to estimate the required sample size for correlation analyses. Sample size tables are provided and these will help researchers to estimate a minimum sample size requirement based on correlation analyses.

Simulations of Two-Dimensional Electronic Correlation Spectra

  • Kim, Hak Jin;Jeon, Seong Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.807-815
    • /
    • 2001
  • Two-dimensional (2D) correlation method, which generates the synchronous and the asynchronous 2D spectrum by complex cross correlation of the Fourier transformed spectra, is an analysis method for the changes of the sample spectrum induced by vari ous perturbations. In the present work, the 2D electronic correlation spectra have been simulated for the cases where the sample spectrum composed of two gaussian bands changes linearly. When only the band amplitudes of the sample spectrum change, the synchronous spectrum shows strong peaks at the band centers of the sample spectrum, but the asynchronous spectrum does not make peaks. When the sample spectrum shifts without changing intensity and width, the synchronous spectrum shows peaks around the initial and final positions of the band maximum and the asynchronous spectrum shows long peaks spanning the shifting range. The band width change produces the complex 2D correlation spectra. When the sample spectrum shifts with band broadening, the width change by 50% of full width at half maximum (FWHM) does not give so large an effect on the correlation spectrum as the spectral shift by one half of FWHM of the sample spectrum.

Generalized Composite Estimator with Intraclass Correlation in p-level Rotation Sampling (P-수준교체표본에서 교체그룹내 상관관계를 고려한 일반화 복합추정량)

  • 박유성;배경화;김기환
    • The Korean Journal of Applied Statistics
    • /
    • v.14 no.1
    • /
    • pp.81-90
    • /
    • 2001
  • One of the Repeated survey which estimates variability of population, we can be consider rotation sample survey. There are two kinds of rotation sample survey - onelevel rotation sample survey and multi-level rotation sample survey. In rotation sample survey, Composite estimator is used to measure level or level change of the population. This study suggests Generalized Composite estimator as considering intraclass correlation in multi-level rotation sample survey, and optimal weight minimizing variance of estimator. Numerical example shows efficiency of Generalized Composite estimator as considering intraclass correlation according to the sample unit and change degree of intraclass correlation in the rotation group.

  • PDF

Correlation Between Lateral Photovoltaic Effect and Conductivity in p-type Silicon Substrates

  • Lee, Seung-Hoon;Shin, Muncheol;Hwang, Seongpil;Park, Sung Heum;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1845-1847
    • /
    • 2013
  • The lateral photovoltaic effect (LPE) can be observed in semiconductors by irradiating a light spot position between electrodes on sample's surface. Because lateral photovoltaic voltage (LPV) is sensitively changed by light spot position, a LPE device has been tried as a position-sensitive detector. This study discusses the correlation between LPV and conductivity in p-type silicon and nano-structured Au deposited p-type silicon (nano-Au silicon), respectively. Conductivity measurement of the sample was carried out using the four-wire method to eliminate contact resistance, and conductivity dependence on LPV was simultaneously measured by changing the light irradiation position. The result showed a strong correlation between conductivity and LPV in the p-type silicon sample. The correlation coefficient was 0.87. The correlation coefficient between LPV and conductivity for the nano-Au silicon sample was 0.41.

The Change of the Correlation between GRBAS Scales and MDVP Parameters according to the Different Length of Voice Samples for MDVP Analysis (음성 Sample의 길이 변화에 따른 MDVP 측정치와 GRBAS 척도간의 상관관계 변화 비교)

  • Pyo, H.Y.;Sim, H.S.;Lim, S.E.
    • Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.71-81
    • /
    • 2000
  • The present study was performed to find efficient and useful length of voice sample for MDVP analysis, by investigating the correlation between perceptual GRBAS scales and objective MDVP measurements, with the five different lengths of voices of 20 patients with vocal polyp: 0.5, 1.0, 1.5, 2.0, 2.5 seconds. The results are following: (1) 1.5-second sample of MDVP showed the highest correlation between the perceptual judgement and objective measurement, and 1.0-second sample showed the lowest. The difference between the two samples was found in the number of the statistically significant correlated pairs of MDVP parameter-GRBAS scale. (2) The two extreme edges of the lengths, 0.5-second and 2.5 second showed no statistically significant difference.

  • PDF

Updating Sample Variance and Correlation Using Sum of Squares and Sum of Cross product (제곱합과 교차곱합의 특성을 이용한 표본분산과 상관계수의 계산)

  • Cho Tae-Kyoung;Shin Mi-Young
    • The Mathematical Education
    • /
    • v.45 no.3 s.114
    • /
    • pp.315-318
    • /
    • 2006
  • In this paper we present the simple updating formulas for a sum of product and a sum of cross product when a new value is added on or a specific value is eliminated from the original data. The sample variance and correlation for the new data set are derived by new computing formulas. Any statistic which is a function of the sum of product and a sum of cross product also can be updated by proposed method even though the original data is not available.

  • PDF

Application of Correlation-Aided DSA(CDSA) Technique to Fast Cell Search in IMT-2000 W-CDMA Systems.

  • Kim, Byoung-Hoon;Jeong, Byeong-Kook;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.2 no.1
    • /
    • pp.58-68
    • /
    • 2000
  • In this paper we introduce the correlation-aided distributed sample acquisition (CDSA) scheme for fast cell search in IMT-2000 W-CDMA cellular system. The proposed scheme incorporates the state symbol correlation process into the comparison-correction based synchronization process of the original DSA scheme to enable fast acquisition even under very poor channel environment. for its realization, each mobile station (MS) has to store in its memory a set of state sample sequences. which are determined by the long-period scrambling sequences used in the system and the sampling interval of the state samples. CDSA based cell search is carried out in two stages : First, the MS first acquires the slot timing by using the primary synch code (PSC) and then identifies the igniter code which conveys the state samples of the current cell . Secondly. the MS identifies the scrambling code and frame timing by taking the comparison-correction based synchronization approach and, if the identification is not done satisfactorily within preset time. it initiates the state symbol correlation process which correlates the received symbol sequence with the pre-stored state sample sequences for a successful identification. As the state symbol SNR is relatively high. the state symbol correlation process enables reliable synchronization even in very low chip-SNR environment. Simulation results show that the proposed CDSA scheme outperforms the 3GPP 3-step approach, requiring the signal power of about 7 dB less for achieving the same acquisition time performance in low-SNR environments. Furthermore, it turns out very robust in the typical synchronization environment where large frequency offset exists.

  • PDF

A Simple Geometric Approach to Evaluating a Bivariate Normal Orthant Probability

  • Lee, Kee-Won;Kim, Yoon-Tae;Kim, U-Jung
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.2
    • /
    • pp.595-600
    • /
    • 1999
  • We present a simple geometric approach which uses polar transformation and elementary trigonometry to evaluating an orthant probability in a bivariate normal distribution. Figures are provided to illustrate the situation for varying correlation coefficient. We derive the distribution of the sample correlation coefficient from a bivariate normal distribution when the sample size is 2 as an application.

  • PDF

Study of Cross Correlation Using DRS(Delayed Reference Sample) for Precision Time Measurement of Input Signal on Multilateration (다변측정감시시스템 신호 입력 시각 정밀 측정을 위한 DRS(Delayed Reference Sample)를 이용한 Cross Correlation 방안 연구)

  • Chang, Jae-Won;Lee, Sang Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.244-250
    • /
    • 2018
  • Multilateration acquires the transponder signal of target from receivers installed on the ground and calculates the position of the target using the difference of the signal acquisition time of each receiver. One of the factors that influence the positioning accuracy of Multilateration using the TDOA calculation method is the error due to the precision measurement of signal input time. When measuring the signal input time at the receiver, the input signal is sampled using the reference clock of the receiver and a reference sample having the same sampling rate is applied to the cross correlation technique. Therefore, the accuracy of the signal input time is proportional to the reference clock. In this paper, the algorithm for precisely measuring the signal input time by performing cross correlation between the input signal of the receiver and DRS(Delayed Reference Sample) is proposed. In order to verify this, we implemented the pulse signal of the transponder that is transmitted from the target using Matlab. Through the simulation, cross correlation between the proposed DRS and the input signal was performed. From this result, the performance of the precise measurement of signal input time was analyzed.

Effect of particle size and scanning cup type for near infrared reflection on the soil property measurement

  • Ryu, Kwan-Shig;Cho, Rae-Kwang;Park, Woo-Churl;Kim, Bok-Jin
    • Near Infrared Analysis
    • /
    • v.1 no.2
    • /
    • pp.35-39
    • /
    • 2000
  • The purpose of this research was to find out suitable soil sample preparation and sample holding tools for NIR reflection radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1,100 to 2,500nm with an InfraAlyzer 500(Bran+Luebbe Co.). Coarse(2.0mm) and fine(0.5mm) soil sample and various sample holding tools were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter and total nitrogen of the soils. Multiple linear regression was used to obtain the best correlation of NIR spectroscopy method. Correlation of NIR spectroscopy method. Correlation of NIR spectra for finely and coarsely sized soil did not show much difference. The standard errors of prediction(SE) using different types of sample holding tools for organic matter, total nitrogen and soil moisture were better than 0.765, 0.041 and 0.63% respectively. From the results it can be concluded that NIR spectroscopy with flow type cell could be used as a fast routine testing method in quantitative determination of organic matter, total nitrogen and soil moisture.