• Title/Summary/Keyword: saliva contamination

Search Result 46, Processing Time 0.027 seconds

EFFECTS OF SALIVA AND BLOOD CONTAMINATION ON DENTIN BONDING (타액 및 혈액 오염이 상아질접착에 미치는 영향)

  • Kim, Ki-Ok;Ahn, Sik-Hwan;Kim, Sung-Kyo;Jo, Kwang-Hun;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.585-601
    • /
    • 1996
  • The purpose of this study was to elucidate the effect of blood-and saliva-contamination during dentin pretreatment procedure on tensile bond strength, and to investigate the effect of contaminant-removing treatments on the recovery of bond strength of dentin bonding agents. Dentin specimens prepared from freshly extracted bovine mandibular anterior teeth were divided into non-contaminated control and contaminated experimental groups. The specimens of the contaminated group were contaminated with saliva or blood after etching or priming procedure, followed by contaminant-removing treatments. All the specimens were bonded with All Bond$^{(R)}$ 2 dentin bonding agent and Bisfil$^{TM}$ composite resin or Scotchbond$^{TM}$ Multipurpose and Z100. After all the bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strengths were measured. The contaminated dentin and fractured dentin surfaces were examined under the scanning electron microscope. The results were as follows : Contaminated specimens showed lower bond strength than non-contaminated ones regardless of the kind of contaminant, contamination time and contaminant-removing treatments, except specimens which were acid-etched following saliva contamination after etching in All Bond$^{(R)}$ 2 groups (p<0.05). Blood contaminant resulted in much bond strength decrease than saliva ones (p<0.01), and contamination after priming resulted in much decrease in bond strength than after etching (p<0.01). Re-etching resulted in increase of bond strength in the specimens contaminated with saliva after etching but not in blood contaminated ones. Re-priming resulted in increase of bond strength in the specimens contaminated after priming regardless of the kind of contaminant.

  • PDF

INFLUENCE OF ARTIFICIAL SALIVA CONTAMINATION ON BONDING OF DENTIN ADHESIVES TO DENTIN (인공타액 오염이 수종 상아질접착제와 상아질간의 결합에 미치는 영향)

  • Ryu, Mee-Ae;Yang, Kyu-Ho;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.383-397
    • /
    • 1992
  • The purpose of this study was to evaluate the influence of artificial saliva contamination on bonding of several dentin adhesives to dentin. Sixty - three human molar teeth extracted within a month were used. Each tooth was sectioned longitudinally in a buccolingual direction to obtain 126 specimens. These specimens were randomly divided into three groups and were treated by Scotchbond 2, Gluma and All bond. Each group was subdivided into three subgroups; normal group not contaminated with artificial saliva, contaminated with artificial saliva and dried group, and contaminated with artificial saliva and washed and dried group. Enamel/dentin bonding agent(Dental Adhesive of Scotchbond 2) was applied and light cured on the treated dentin surfaces. Thereafter P - 50 were cured on them, and specimens were stored in $37^{\circ}C$ artificial saliva for 24 hours before measuring shear bond strength. Shear bond strengths were determined using an universal testing machine with cross head speed 1mm/min and SEM examinations were conducted to evaluate the resin - dentin interface and degree of penetrating resin string into the dentinal tubules. The following results were obtained. 1. Normal groups not contaminated with artificial saliva showed greater shear bond strength than any other group contaminated with artificial saliva(P<0.01). 2. The shear bond strengths showed no significant difference between washed groups with distilled water and not washed groups after contamination with artificial saliva(P>0.05). 3. In normal groups, the shear bond strength of A group was significantly greater than in any other group(P<0.01). 4. In Sand G groups, fractures after shear bond strength tests occured adhesively on resintooth interface in all specimens. But in A groups, fracture of the normal group occured cohesively in dentin and fracture of the contaminated groups occured adhesively and cohesively. 5. On SEM examination, the number of resin strings penetrated into dentinal tubules were the greatest in normal groups, followed by, in descending order, washed groups and not washed groups after contamination with artificial saliva.

  • PDF

Effect of Saliva Contamination Stage and Different Decontamination Procedures on Bonding Strength of Resin-Modified Glass Ionomer (레진강화형 글라스아이오노머의 초기 결합력과 타액오염 제거의 상관관계)

  • Go, Hanho;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.158-164
    • /
    • 2019
  • The purpose of this study was to compare the bond strength of resin-modified glass ionomer (RMGI) to dentin with saliva contamination at different stages and using different decontamination procedures. Extracted human permanent molars were embedded onto acrylic resin with the dentin surface exposed. Group I was a control group that was conditioned with polyacrylic acid (PAA). Groups II and III were contaminated with saliva before PAA conditioning and Groups IV, V, and VI were contaminated with saliva after PAA conditioning. After saliva contamination, Groups II and IV were dried, Groups III and V were rinsed and dried, and Group VI was additionally conditioned with PAA. After surface treatment, the dentin specimens were filled with RMGI. Group I showed significantly higher bond strength than the other groups. Group VI showed a significantly higher bond strength than the other saliva contaminated groups. However, there were no significant differences in the failure mode between the different groups. Saliva contamination impaired the bond strength of RMGI to dentin, regardless of when the saliva contamination occurred. Decontamination with washing and drying could not improve the shear bond strength of RMGIC. When saliva contamination occurred after PAA conditioning, additional PAA conditioning improved the shear bond strength.

Effects of Saliva Contamination on Shear Bond Strength with Conventional, Moisture Insensitive, and Self-Etching Primers (Moisture Insensitive Primer와 Self-Etching Primer를 사용한 교정용 브라켓 접착 시 타액오염이 전단결합강도에 미치는 영향 비교)

  • Oh, Yoonjeong;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • The aim of this study was to compare the shear bond strengths of orthodontic bracket with Conventional primer (CP), Moisture insensitive primer (MIP), and Self-etching primer (SEP). In addition, the effect and the timing of saliva contamination on shear bond strength was evaluated. A total of 135 bovine mandibular incisors were used in the study and divided into 3 groups. Group I, II and III were used CP, MIP, SEP, respectively. Each group was then divided into three subgroups: the group without saliva contamination, the group with primer application after saliva contamination, and the group with saliva contamination after primer application. After the primer application, the metal bracket for the lower incisor was attached and the shear bond strength was measured. The mean shear bond strengths was highest with CP and lowest with SEP in dry condition. However, CP showed a significant decrease in shear bond strength in the presence of saliva contamination. MIP and SEP showed no significant decrease in shear bond strength with saliva contamination.

ADHESIVE PROPERTY OF POLYSULFIDE IMPRESS10N MATERIAL ON THE TRAY RESIN AND BORDER HOLDING MATERIALS (타액오염이 트레이 레진 및 변연 형성재와 Polysulfide 인상재의 접착력에 미치는 영향)

  • Kim, Yong-Hak;Yang, Hong-Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.650-658
    • /
    • 2000
  • This study was investigated to compare the bond strength of polysulfide adhesive between tray resin and border molding materials and to evaluate the effect of saliva contamination on them. We made the 135 resin tray secimens with a dimension of $1{\times}1{\times}1cm$ and divided them into 3 groups by the materials 1) Quicky group, 2) Compound group, and 3) Impregum group Each group was subdivided by saliva contimination. Group S1 : applied adhesive without saliva contamination Group S2 : applied adhesive after drying 15seconds after saliva contamination Group S3 : applied adhesive no after saliva contamination. Tensile tests were performed with a Universal Load testing machine. Results showed Impregum group significantly higher bond strength than Quicky group, but there was no significant difference in adhesive bond strength between Compound group and Quicky group in experimental group by materials In experimental group by saliva contamination, S1 group is significantly higher bond strength than S2 group and S2 group is significantly higher bond strength than S3 group in Quicky group and S1, S2 group is significantly higher bond strength than S3 group in Compound group and Impregum group. Impression compound and Impregum F which are usually used as an individual tray border mold-ing material can be said to be satisfied in adhesive bond strength to polysulfide impression materials. After try-in and clinical adjustment are performed, a custom tray should be properly rinsed and air dried before tray adhesive was placed.

  • PDF

The Effect of Saliva in Squamous Cell Carcinoma(SCC) and Thyroid Function Test with Radioimmunoassay (타액이 편평상피세포암(SCC)과 갑상선기능검사에 미치는 영향)

  • Cho, Man Ick;Moon, Ki Choon;Kim, Hea Sook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.269-273
    • /
    • 2004
  • Squamous cell carcinoma(SCC) associated antigen is a subfraction of TA-4, a tumor-associated antigen first described by Kato and Torigoe in 1977. TA-4, obtained from squamous cell carcinoma cancer tissue of the uterine cervix, has been characterized as a glycoprotein with a molecular weight of approximately 45,000 daltons. SCC antigen has been studied in other squamous cell malignancies including lung, esophagus, head and neck, anal canal, and skin. SCC antigen is shed naturally through sweat, saliva and other body fluids. Contamination of specimens, tray, bead dispenser or other accessories with sweat, saliva or aerosols can cause falsely elevated values. To reduce the possibility of contamination, gloves should be worn in all phases of assay preparation, and when handling specimens, accessories or reagents that will be used in SCC and Thyroid function test(TFT).

  • PDF

EFFECT OF SURFACE CONTAMINATION ON THE TRANSVERSE STRENGTH OF THE RELINED DENTURE (첨상면 오염이 레진 의치상의 파절강도에 미치는 영향)

  • Kim, Jeong-Hyun;Bae, Jung-Soo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 1993
  • Autopolymerising and visible light cured resin are used to reline dentures. But relined surface are easily contaminated by water or saliva in the mouth during clinical procedure. This study was to find out the effect of surface contamination on the transverse strength of the relined denture base. To accomplish this, the specimens of $65\times10\times3mm$ were made with heat-cured(Lucitone 199), visible light-cured(Triad), and autopolymerizing resin(Kooliner). Measurements of transverse strength were taken for each specimen. Specimens made of heat-cured resins, sizing $65\times10\times1.5mm$, were relined with heat-cured, light-cured, and autopolymerizing resin, respectively. Specimens relined with autopolymerizing and light-cured resins were further classified into not-contaminated, water-contaminated and saliva-contaminated groups. Again, measurements of the transverse strength were taken for each group. The results were as follows 1. The transverse strength of heat-cured resin was superior to all the other resins. 2. The transverse strength of each specimen decreased after relining in the following order, heat-cured, visible light-cured, and autopolymerizing resin. 3. Surface contamination produced an decrease in transverse strength, especially in the saliva contaminated group. According to these results, water or saliva contamination should be avoided during intraoral relining procedures.

  • PDF

Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

  • Mostafavi, Azam Sadat;Memarian, Maryam;Seddigh, Mohammad Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.65-70
    • /
    • 2021
  • Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.

Effect of Saliva Decontamination on Bond Strength of 1-step Self-etching Adhesives to Dentin of Primary Posterior Teeth (한 단계 자가부식 접착제를 이용한 복합레진 수복 시 타액오염 후 처치 방법에 따른 미세인장강도 비교)

  • Lee, Junhee;Kim, Shin;Jeong, Taesung;Shin, Jonghyun;Lee, Eungyung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.274-282
    • /
    • 2019
  • The purpose of this study was to evaluate effect of saliva decontamination procedures on microtensile bond strength (MTBS) of 1-step self-etching adhesives to dentin of primary posterior teeth. 63 sound primary-posterior teeth were randomly divided into 3 groups according to different kinds of 1-step self-etching adhesives: $Scotchbond^{TM}$ Universal Adhesive (SBU), All-Bond $Universal^{(R)}$ (ABU), and $Tetric^{(R)}$ N Bond Universal (TBU). Each group was randomly categorized into 7 subgroups: (I) application of adhesive without saliva contamination (control); (II - IV) contamination by saliva before photopolymerization; (V - VII) contamination by saliva after photopolymerization; (II, V) decontamination by drying; (III, VI) decontamination by washing and drying; (IV, VII) decontamination by washing, drying, and reapplication of adhesive. All samples were cut into the blocks. At least 15 blocks were tested for each subgroup. For SBU and ABU, the MTBS values of subgroups (I, IV, VII) were significantly higher than those of subgroups (II, III, V, VI). For TBU, the MTBS values of subgroups (I, IV) was significantly higher than those of subgroup (II, III, V, VI). The MTBS of 3 adhesives was reduced by saliva contamination. The adhesive strength on dentin of primary posterior teeth was restored by reapplication of the adhesives after washing and drying.

The effect of contamination of the etched matal retainer on resin bonding strength (금속 유지장치의 오염이 레진 접착 결합력에 미치는 영향)

  • Park, Ha-Ok;Bang, Mong-Sook
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.217-224
    • /
    • 2002
  • The purpose of this study was to evaluate the influence of saliva contamination on the resin bonding of the etched metal retainers. The test samples were made of Verabond, and divided into 3 groups. Retainers in group1 had normally etched metal surfaces. Retainers in group2 had normally etched metal surfaces which were saliva-contaminated for 30 seconds and cleaned with streaming, luke-warm for 1 minute and dried thoroughly. Retainers in group3 had normally etched metal surfaces which were saliva- contaminated for 30 seconds and dried thoroughly without water-cleansing. Each 3 group specimen was watched on SEM. A resin core, 5mm in diameter and 6mm in length, was made of Panavia using Teflon mold on the each specimen. These 3 groups were tested to evaluate shear bond strength, using universal testing machine. The results were as follows : 1. The shear bond strength showed no significant difference between group1 and group2. 2. The shear bond strength showed significant difference between group1 and group3. 3. The shear bond strength significant difference between group2 and group3. 4. Scanning electron microscope photographs of group1 and group2 showed no signs of contamination but of group3 showed somewhat contaminated.