• Title/Summary/Keyword: safety device

Search Result 1,809, Processing Time 0.033 seconds

Development of an All-in-one Attachment-based PHC Pile Head Cutting Robot Prototype (All-in-one 어태치먼트 기반 PHC 파일 원커팅 두부정리 자동화 로봇의 프로토타입 개발)

  • Yeom, Dong-Jun;Park, Ye seul;Kim, Jun Sang;Kim, Young Suk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.2
    • /
    • pp.37-44
    • /
    • 2019
  • The primary objective of this study is to develop a prototype of all-in-one attachment-based PHC pile head cutting robot that improves the conventional work in safety, productivity, and quality. For this, the following research works are conducted sequentially; 1)literature review, 2)development of an all-in-one attachment-based PHC pile head cutting robot prototype, 3)performance evaluation of each device, 4)economic analysis of an automated method. As a result, PHC pile cutting level sensing device, PHC pile cutting device, PHC pile handling device are developed. Futhermore, working process of an automated method is developed based on result of performance evaluation. According to the economic analysis result, the cost of the automated method was 21.37% less than that of the conventional method, and the economic efficiency was also superior(ROR 215.44%, Break-even Point 5.52month). It is expected that conclusions for future improvements are used in the development of the all-in-one attachment-based PHC pile head cutting robot to practical use.

Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater (오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발)

  • Cho, Heuy-Nam;Choi, Sang-Il
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2009
  • The compressed packer device is designed to improve the underground contamination prevention facilities of ground water wells. As for the device, the installation is simple because of the safety lock device and the compression of the casing are simple the installation is simple. There is no leakage of ground water because the pressure resistance with $4.5\;kg/cm^2$ makes it equipped with the watertightness The single casing is installed and the reaming for grouting is possible with 300 mm excavation so that installation cost can be saved. Silicon rubber is used for the compressed packer so that the extension rate is 590%. In terms of environmental pollution, it is an environmental friendly product which does not contain harmful ingredients such as Pb, Cd, and phenol. below the standard or undetectable level Furthermore, the installation costs are 35 to 62% or lower than the conventional grouting construction method and are 87% or lower than the expansion packer construction method, the new environmental technology No.47 Also, the device is designed to meet the relevant regulations such as Rules on Preserving the Ground Water Quality, The Standard on Jeju Island Ground Water Development and Facility Installation and Management, and The Plan and Guideline on Operating and Managing the Small-Scale Tap Water Facilities of Ministry of Environment and Ministry of Food, Agriculture, Forestry and Fisheries.

A Study on the Application of School Guard to School Police System (학교지킴이의 청원경찰 적용 방안에 관한 연구)

  • Park, Yong Soo
    • Convergence Security Journal
    • /
    • v.13 no.5
    • /
    • pp.177-186
    • /
    • 2013
  • It has been long time since the social concern about school safety was fully raised in our country. The accidents, such as sexual violence against young children, traffic accident when going to and from school, psychological violence by bullying, extorting money & violence and so on, frequently happen. Under the circumstances that this kind of school safety problems are concerned greatly by society, it is very important for schools to create the environment in which children can have a safe living. The study focuses on the necessity and introduction of a professional school police system to establish the sexual violence prevention system in advance. The system, practically and systematically organized, can prevent various kinds of safety accidents and form the agreement of family, regional society, and related institutions alike. It is also supposed to emphasize the strengthening of school safety by its operation.

A Study on the Removal of Electrostatic using Transmitted Ions Generated Soft X-ray with Compressed Air (기류방출형 연X선 조사에 의한 정전기 제거 장치에 관한 연구)

  • Kwon, Sung-Yul;Lee, Dong-Hoon;Choi, Jae-Wook;Seo, Min-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • It is a well known fact that the LCD and Semiconductor Devices are a central part of IT industry which is important in the present and the future. But the biggest problem of Semiconductor and LCD manufacturing is maintaining a cleaning room environment. For this reason, the soft X-ray type Ionizer was used as the electrostatic reducer device, which protects damage of the product against electrostatic discharge in the manufacturing process. Therefore it is a essential important factor during Semiconductor and LCD production process. But the soft X-ray has a intrinsic problem with harmful to human being in case of soft X-ray exposure. That's reason we have the research to solve above problem and made an apparatus that it was covered with shielding structure to protect X-ray radiation to outside. And besides, it has a possibility to eliminate the charged electrostatic in the narrow space through the slot for Ion emissions with dual soft X-ray sources on the both side. It is also not make the particles from itself when it has been operated.

Numerical Analysis for Flow Distribution inside a Fuel Assembly with Swirl-type Mixing Vanes (선회 형태 혼합날개가 장착된 연료집합체 내부유동 분포 수치해석)

  • Lee, Gonghee;Shin, Andong;Cheong, Aeju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.5
    • /
    • pp.186-194
    • /
    • 2016
  • As a turbulence-enhancing device, a mixing vane installed at a spacer grid of the fuel assembly plays a role in improving the convective heat transfer by generating either swirl flow in the subchannels or cross flow between fuel rod gaps. Therefore, both configuration and arrangement pattern of a mixing vane are important factors that determine the performance of a mixing vane. In this study, in order to examine the flow distribution features inside $5{\times}5$ fuel assembly with swirl-type mixing vanes used in benchmark calculation of OECD/NEA, simulations were conducted with commercial CFD software ANSYS CFX R.14. Predicted results were compared to data measured from MATiS-H (Measurement and Analysis of Turbulent Mixing in Subchannels-Horizontal) test facility. In addition, the effect of swirl-type mixing vanes on flow pattern inside the fuel assembly was described.

Evaluation Technique of Importance of Monitoring Systems for Earth and Rockfill Dam Safety (필댐 안전관리를 위한 계측기 중요도의 평가기법)

  • Lee, Jong-Wook;Kim, Jae-Hong;Oh, Byung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.874-882
    • /
    • 2009
  • Continuous monitoring of dam performance is essential to earth and rockfill dams safety because it has to be guaranteed for safety during construction period of course and from initial impounding to a long term maintenance period of dam. Among the 31 dams managed by Kwater at present, the proportion of dams being over 20 years after completion of construction is 42% and it is estimated that the loss rate of monitoring devices will be increase as times. Monitoring devices would be impossible to repair since those are mostly installed in the dam body and foundation. If repairing of monitoring devices is possible, the expenditure will be expensive. Therefore reasonable decision making for abandonment, repair and alternation for loss of monitoring devices would be needed through the establishment of key instrument for earth and rockfill dam safety. In this study the process of monitoring for safety were modeled by failure modes of dams, adverse conditions related to failure mode, indicators of adverse condition and monitoring devices The relationship between failure mode and monitoring devices were systematically analyzed and established and evaluation technique for qualifying the importance of monitoring devices were presented.

  • PDF

The Development of the System Operation Safety of Unmanned Parcel Storage System with ICT and Cold Chain Technology (ICT 콜드체인 기술이 적용된 무인 택배물품 보관장치의 시스템 운영 안전성 확보를 위한 연구)

  • Park, Jae-Min;Kim, Young-Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.3
    • /
    • pp.29-37
    • /
    • 2022
  • The development of technology related to the Fourth Industrial Revolution and the growth of the online market due to pandemic are continuing the growth of the logistics market for product delivery. If it is difficult to deliver the product directly to the customer during delivery, storage and delivery using the unmanned courier box are being carried out. However, existing storage boxes are not actively used due to lack of usability even though they have the advantage of storing goods and delivering non-face-to-face. In addition, existing courier boxes are not prepared for cold chain transportation. The unmanned delivery storage device with ICT cold chain technology should be developed to prepare for the transition to non-face-to-face society, to improve logistics efficiency and meet user's requirements. Also, it is necessary to consider the measures to reduce the safety problems that may occur during the use and maintenance of the automatic system. This study conducted a model-based analysis for the development of unmanned delivery storage devices with ICT cold chain technology, and conducted a study to derive the system development specifications that meet the requirements and secure safety and apply them to the development process.

EMC Safety Margin Verification for GEO-KOMPSAT Pyrotechnic Systems

  • Koo, Ja-Chun
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • Pyrotechnic initiators provide a source of pyrotechnic energy used to initiate a variety of space mechanisms. Pyrotechnic systems build in electromagnetic environment that may lead to critical or catastrophic hazards. Special precautions are need to prevent a pulse large enough to trigger the initiator from appearing in the pyrotechnic firing circuits at any but the desired time. The EMC verification shall be shown by analysis or test that the pyrotechnic systems meets the requirements of inadvertent activation. The MIL-STD-1576 and two range safeties, AFSPC and CSG, require the safety margin for electromagnetic potential hazards to pyrotechnic systems to a level at least 20 dB below the maximum no-fire power of the EED. The PC23 is equivalent to NASA standard initiator and the 1EPWH100 squib is ESA standard initiator. This paper verifies the two safety margins for electromagnetic potential hazards. The first is verified by analyzing against a RF power. The second is verified by testing against a DC current. The EMC safety margin requirement against RF power has been demonstrated through the electric field coupling analysis in differential mode with 21 dB both PC23 and 1EPWH100, and in common mode with 58 dB for PC23 and 48 dB for 1EPWH100 against the maximum no-fire power of the EED. Also, the EMC safety margin requirement against DC current has been demonstrated through the electrical isolation test for the pyrotechnic firing circuits with greater than 20 dB below the maximum no-fire current of the EED.