Distribution of Total Mercury in Korean Coastal Sediments (한반도 연안역 표층퇴적물 내 총 수은 분포 특성)

  • JOE, DONGJIN;CHOI, MANSIK;KIM, CHANKOOK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.23 no.2
    • /
    • pp.76-90
    • /
    • 2018
  • To determine the distribution of mercury (Hg) in the coastal surface sediments around the Korean peninsula, the baseline concentration of Hg was estimated, the extent of contamination was assessed, and the factors controlling the distribution were discussed. The concentrations of Hg in surface sediments were significantly high in Jinhae-Masan Bay in the South Sea, Ulsan-Onsan Bay and Yeongil Bay in the East Sea, but Hg in other sediments showed a similar distribution to Cs and relatively very low concentration between 0.21 and $39.5{\mu}g/kg$ ($13.6{\pm}7.80{\mu}g/kg$). Compared to the sediment quality guidelines in Korea, 8 % of the surface sediments (n=282) analyzed in this study exceeded the values of the threshold effects level (TEL), and six sediments collected around Onsan Port were higher than the value of the probable effects level (PEL). The contamination levels of Hg were assessed by the enrichment factors using the baseline concentration (2.06Cs+1.75) based on the residual analysis from the linear regression line for Cs, and further, factors controlling the distribution of Hg were discussed by the comparison with geochemical substances depending upon the Hg enrichment level. Hg concentrations were correlated well with Cs concentration in the range of less than 1.69 of EF implying grain size control, while in the range of 1.69 and 4.03 Hg concentrations were correlated well with Fe oxyhyroxide and organic carbon contents, which indicates Hg was enriched by superior sorption capability. On the meanwhile, samples with higher EFs (4.03 to 74.9) showed fairly positive correlations with other metals (Cu, Zn, Pb) rather than geochemical substances. For samples in Youngil Bay and Ulsan-Onsan Bay (n=30), Hg concentrations were correlated only with other metals rather than geochemical substances implying simultaneous supply of metal particles from metal refineries. But samples at Gosung, Sokcho and Uljin coast were correlated well with organic carbon even though they had high EFs. In addition, samples in Jinhae-Masan Bay with high contents of S were enriched by relatively high sulfide formation.

A Study on Applicability of Stabilizing Pile to Foundation Soil of Slope with Various Strength Parameters (사면하부지반의 강도정수에 따른 억지말뚝 적용성 연구)

  • Lee, Seung-Hyun;Jang, In-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.331-337
    • /
    • 2016
  • Several foundation soil conditions below a homogeneous sand slope were assumed and slope stability analyses were conducted to determine the soil condition, in which a stabilizing pile can be used to increase the factor of safety against sliding. The assumed heights of the sand slope were 5m and 10m. For a 5m slope height, a stabilizing pile can be used in the foundation soil with a $15^{\circ}$ internal friction angle and a cohesion of 10kPa. For a 10m slope height, a stabilizing pile can be used in the foundation soil with a $20^{\circ}$ internal friction angle and a cohesion of 10kPa and a stabilizing pile can be used in the foundation soil with a $0^{\circ}$ internal friction angle and 40kPa, 45kPa and 50kPa of cohesion. According to the analysis results of stabilizing pile-reinforced foundation soil, the length of the stabilizing pile and magnitude of the maximum bending moment were strongly affected by the internal friction angle of the foundation soil. The lengths of stabilizing pile, for an internal friction angle of $0^{\circ}$ were 4.6, 8.0 times greater than those with an internal friction angle of $5^{\circ}$. The magnitude of the maximum bending moment of the stabilizing pile for an internal friction angle of $0^{\circ}$ was 24.6 times greater than that for an internal friction angle of $5^{\circ}$. Practically, a stabilizing pile cannot be used for foundation soil with an internal friction angle of $0^{\circ}$. Considering the results derived from this study, the effects of a stabilizing pile can be maximized for soft foundation soil that is embanked with a slow construction speed.

Microbiological Hazard Analysis of Hot Pepper Farms for the Application of Good Agricultural Practices (GAP) System (농산물우수관리제도 (GAP) 적용을 위한 고추농가의 미생물학적 위해도 평가)

  • Nam, Min-ji;Heo, Rok-Won;Lee, Won-Gyeong;Kim, Kyeong-Yeol;Chung, Do-Yeong;Kim, Jeong-Sook;Shim, Won-Bo;Chung, Duck-Hwa
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.163-173
    • /
    • 2011
  • The objective of this study was to determine microbiological risk factors in hot pepper farms for the application of good agricultural practices (GAP). Samples were collected from cultivation environments and utensils, plants, workers, and air at 3 hot pepper farms located in Cheongsong, Korea and were tested to detect sanitary indications [aerobic plate bacteria (APC), coliform, and Escherichia coli], foodborne pathogens, and fungi. APC, coliform, and fungi were detected at the levels of 0.7~6.2, 0.2~4.7, and 0.4~4.3 log CFU, respectively, in the three farms. Four (4.4%; l leaf, l irrigation water, and 2 soil) of 90 samples collected were revealed to be E. coli positives. For foodborne pathogens, Staphylococcus aureus was only detected at $1.0log\;CFU/100cm^2$ in the worker's cloth of B farm, and Bacillus cereus was detected at the levels 1.0~2.5 log CFU in the cultivation environments and utensils and worker of B and C farms. However, other pathogens were not detected. The results demonstrated potential microbiological risks for hot pepper cultivated in the farms. Therefore, a management system to minimize the microbial risk such as GAP is required to ensure the safety of hot pepper.

Comparative Study of Litsea japonica Leaf and Fruit Extract on the Anti-inflammatory Effects (까마귀쪽나무 열매와 잎의 항염증 효과 비교 연구)

  • Namkoong, Seung;Jang, Seon-A;Sohn, Eun-Hwa;Bak, Jong Phil;Sohn, Eunsoo;Koo, Hyun Jung;Yoon, Weon-Jong;Kwon, Jung-Eun;Jeong, Yong Joon;Meng, Xue;Han, Hyo-Sang;Kang, Se Chan
    • Korean Journal of Plant Resources
    • /
    • v.28 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • The present study aimed to investigate comparative anti-inflammatory effects of Litsea japonica fruit and leaf extract considering the balance of safety and efficacy. Dose response studies were performed to determine the inhibitory effects of 70% EtOH extract of leaf (L70%) on the pro-inflammatory enzymes expression, COX-2/PGE2 and NO/iNOS, and pro-inflammatory cytokines production, IL-$1{\beta}$, IL-6, and TNF-$\alpha$ in lipopolysaccharide (LPS)-stimulated RAW 264.7 cells. We also examined comparative effects of 30 and 70% EtOH extract of fruits (F30% and F70%) at low concentration ($10{\mu}g/ml$ ) in the same conditions. L70% at 50 and $100{\mu}g/ml$ showed inhibitory effects on almost all the inflammatory mediators we examined except for COX-2 regulation, but there were no effects at $10{\mu}g/ml$. Since $100{\mu}g/ml$ of L70% have 18.2% cytotoxicity, we compared the effects of fruit extract, F30% and F70% at $10{\mu}g/ml$ on the regulation of NO/iNOS, PGE2, IL-$1{\beta}$, IL-6, and TNF-$\alpha$ and obtained that fruit extacts are more efficacious and safe than leaf. This study suggests that the 30% EtOH fraction of L. japonica fruit could be a good candidate for development as a functional food supplement in the prevention of inflammatory disorders.

Analysis of Fungicide Prochloraz in Platycodi Radix by GC-ECD (GC-ECD를 이용한 한약재 길경(Platycodi Radix) 중 살균제 Prochloraz의 분석)

  • Oh, Gyeong-Seok;Yoon, Myung-sub;Yang, Seung-Hyun;Choi, Hoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.353-358
    • /
    • 2021
  • BACKGROUND: Prochloraz has been widely used as an imidazole fungicide on fruits and vegetables in Korea. Analytical approaches to evaluate prochloraz residues in herbal medicine are required for their safety management. In this study, we developed a GC-ECD method for quantitative determination of prochloraz in Platycodi Radix. The metabolite 2,4,6-trichlorophenol (2,4,6-T) was used as a target compound to evaluate total prochloraz residues as it is categorized to a representative residue definition of prochloraz. All residues containing 2,4,6-T were converted to 2,4,6-T and subjected to GC-ECD. METHODS AND RESULTS: In order to verify the applicability, the method was optimized for determining prochloraz and it metabolite 2,4,6-T in Platycodi Radix. Prochloraz and its metabolite 2,4,6-T residuals were extracted using acetone. The extract was diluted with and partitioned directly into dichloromethane to remove polar co-extractives in the aqueous phase. The extract was decomposed to 2,4,6-T, and then the partitioned ion-associate was finally purified by optimized aminopropyl solid-phase extraction (SPE). The limits of quantitation of the method (MLOQs) were 0.04 mg/kg and 0.02 mg/kg, respectively for prochloraz and 2,4,6-T, considering the maximum residue level (MRL) of prochloraz as 0.05 mg/kg in Platycodi Radix. Recovery tests were carried out at two levels of concentration (MLOQ, 10 MLOQ) and resulted in good recoveries (82.1-89.7%). Good reproducibilities were obtained (coefficient of variation < 2.8%), and the linearities of calibration curves were reasonable (r2 > 0.9986) in the range of 0.005-0.5 ㎍/mL. CONCLUSION(S): The method developed in this study was successfully validated to meet the guidelines required for quantitative determination of pesticides in herbal medicine. Thus, the method could be useful to monitor prochloraz institutionally in herbal medicine.

New Perspectives on Sunday School of Korean Church for Next Generation (다음 세대와 한국교회 주일학교의 새 전망)

  • Kim, Jeong Joon
    • Journal of Christian Education in Korea
    • /
    • v.67
    • /
    • pp.11-44
    • /
    • 2021
  • In the early 21st century, the global COVID-19 pandemic, which has arisen during the development of the technological science of the Fourth Industrial Revolution, has been a great challenge in all fields including politics, economy, industry, education and religion in Korean society. To prevent the spread of the COVID-19 epidemic, the Korean government announced 'social distancing guidelines,' focused on the 'prohibition of three conditions'(crowd, closeness, airtight) for safety reasons. These quarantine guidelines made it more difficult for Korean churches and Sunday schools to operate. In general, looking at the statistical data of the major denominations of the Korean Church in the second half of the 20th century, shows that the Church has entered a period of stagnant or declining growth. Data also show that the number of students attending Sunday School is decreasing. The researcher identified four causes of the crisis faced by the Korean church and Korean Sunday school entering the 21st century. These trends are influenced by the tendencies of postmodernism, the deconstruction of modern universalism, the certainty and objectivity of knowledge, and the grand narrative and worldview of diffusion. Moreover, it is a phenomenon in which the young population decreases in contrast to the increasing elderly population in the age of population cliff in Korean society. Sunday Schools are also facing a crisis, as the youth population, who will become the future heroes of the Korean church, is declining. Finally, constraints of Church and Sunday school education activities are due to COVID-19 Pandemic. As analysis shows the loss of the Church's educational vision and a decrease in the passion for education. Accordingly, the researcher suggests four new strategies for the next generation of Korean Sunday schools, whose ranges from 200 members or less; this range covers the majority of Sunday School program run by churches in Korea. First, in the age of postmodernism, a time of uncertainty and relativism, Christian Societies requires teachers who are certain of absolute Christian truth and faith. Second, in an era of declining population cliffs for younger generations, a shift to a home-friendly Sunday school paradigm is needed. Third, during the COVID-19 pandemic, educational activities must appropriately utilize face-to-face and non-face-to-face communication. Finally, even in difficult times, Korean Sunday school should nevertheless remember the Lord's great commandment(Matthew 28:18-20) and restore the vision and passion of education to announce and teach the gospel. The researcher hopes that this study will provide small, positive steps in rebuilding Korean Sunday school educational activities for future generations in difficult times.

Analysis of Reentry Test for the Donors Showing Reactivity or Grey Zone in a HBV Surface Antigen Assay by a Chemiluminescent Immunoassay (화학발광면역법에 의한 HBV 항원선별검사에서 양성 및 Grey Zone 결과를 보인 헌혈자의 헌혈 보류 해제 검사 결과 분석)

  • Shin, Sunmi;Kang, Jungwon;Lee, Kyeong Rak;Shin, Geon Sik;Kang, Jae-won;Seo, Young Ik;Min, Hyukki
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.301-309
    • /
    • 2018
  • Background: If donors who were deferred due to the reactivity or grey zone in HBV surface antigen (HBsAg) assay want to donate blood again, they need to pass reentry tests. On the other hand, approximately half of the donors who are subject to the reentry tests cannot be reentered. This study examined the association between the sample to cutoff (S/Co) value of the HBsAg assay and the final results of the reentry test. Methods: This study analyzed the S/Co values of the HBsAg assay and the final results of the reentry tests for the 3,947 donors from January 2008 to December 2017 using the database of Blood Information Management System of the Korean Red Cross. Results: 1,767 donors (44.8%) were not reentered among 3,947 deferred donors. Among 1,585 donors showing ${\geq}10$ of the S/Co value in the HBsAg screening test, 1,542 donors (97.3%) were not reentered. The additional reentry tests were performed on 120 donors who were not reentered in the first reentry test; 98 donors (81.7%) were still not reentered. Overall, 4.6% of the donors showing a grey zone in the HBsAg assay were not reentered. Conclusion: The reentry test needs to be restricted for the deferred donors showing a more than 10 S/Co value. The application of the grey zone of current HBsAg assay will need to be continued to enhance the HBV-related blood safety.

Study on relationship between caffeine intake level and metabolic syndrome and related diseases in Korean adults: 2013 ~ 2016 Korea National Health and Nutrition Examination Survey (한국 성인의 카페인 섭취 수준이 대사증후군 및 관련 질환과의 관련성 연구 : 2013~2016 국민건강영양조사 자료 활용)

  • Lee, Jung-Sug;Park, Hyoung-Seop;Han, Sanghoon;Tana, Gegen;Chang, Moon-Jeong
    • Journal of Nutrition and Health
    • /
    • v.52 no.2
    • /
    • pp.227-241
    • /
    • 2019
  • Purpose: This study examined the relationship between caffeine intake and metabolic syndrome in Korean adults using the 2013 ~ 2016 Korea National Health and Nutrition Examination Survey data (KNHANES). Methods: The caffeine database (DB) developed by Food and Drug Safety Assessment Agency in 2014 was used to estimate the caffeine consumption. The food and beverage consumption of the 24 hr recall data of 2013 ~ 2016 KNHANES were matched to items in the caffeine DB and the daily caffeine intakes of the individuals were calculated. The sample was limited to non-pregnant healthy adults aged 19 years and older, who were not taking any medication for disease treatment. Results: The average daily caffeine intake was 41.97 mg, and the daily intake of caffeine of 97% of the participants was from coffee, teas, soft drinks, and other beverages. Multivariate analysis showed that the caffeine intake did not affect metabolic syndrome, hypertension, low HDL-cholesterol, and abdominal obesity. Diabetes and hypertriglyceridemia, however, were 0.76 (95% CI: 0.63 ~ 0.93), and 0.87 (95% CI: 0.77 ~ 0.98) in third quintile (Q3), and 0.66 (95% CI: 0.53 ~ 0.82) and 0.83 (95% CI: 0.73 ~ 0.94) in fourth quintile (Q4) compared to Q1, respectively. Therefore, caffeine intake of 3.66 ~ 45.81 mg per day is related to a lower risk of diabetes and hypertriglyceridemia. Conclusion: The study showed that adequate caffeine intake (approximately 45 mg) was associated with a lower prevalence of diabetes and hypertriglyceridemia. Therefore, it can be used as a guideline for the adequate level of caffeine intake for maintaining health.

Seismic response characteristics of the hypothetical subsea tunnel in the fault zone with various material properties (다양한 물성의 단층대를 통과하는 가상해저터널의 지진 시 응답 특성)

  • Jang, Dong In;Kwak, Chang-Won;Park, Inn-Joon;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1061-1071
    • /
    • 2018
  • A subsea tunnel, being a super-sized underground structure must ensure safety at the time of earthquake, as well as at ordinary times. At the time of earthquake, in particular, of a subsea tunnel, a variety of response behaviors are induced owing to relative rigidity to the surrounding ground, or difference of displacement, so that the behavior characteristics can be hardly anticipated. The investigation aims to understand the behavior characteristics switched by earthquake of an imaginary subsea tunnel which passes through a fault zone having different physical properties from those of the surrounding ground. In order to achieve the aim, dynamic response behaviors of a subsea tunnel which passes through a fault zone were observed by means of indoor experiments. For the sake of improved earthquake resistance, a shape of subsea tunnel to which flexible segments have been applied was considered. Afterward, it is believed that a D/B can be established through 3-dimensional earthquake resistance interpretation of various grounds, on the basis of verified results from the experiments and interpretations under various conditions. The present investigation performed 1 g shaking table test in order to verify the result of 3-dimensional earthquake resistance interpretation. A model considering the similitude (1:100) of a scale-down model test was manufactured, and tests for three (3) Cases were carried out. Incident seismic wave was introduced by artificial seismic wave having both long-period and short-period earthquake properties in the horizontal direction which is rectangular to the processing direction of the tunnel, so that a fault zone was modeled. For numerical analysis, elastic modulus of the fault zone was assumed 1/5 value of the modulus of individual grounds surround the tunnel, in order to simulate a fault zone. Resultantly, reduced acceleration was confirmed with increase of physical properties of the fault zone, and the result from the shaking table test showed the same tendency as the result from 3-dimensional interpretation.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.