• Title/Summary/Keyword: safe room

Search Result 202, Processing Time 0.032 seconds

A Study on the Microbiological Quality of Drinking Water and Changes During Storage

  • Kim, Jong-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.517-521
    • /
    • 2007
  • To assess possible risks from the consumption of drinking water from various sources, a survey of the microbiological quality of tap water, commercial bottled drinking water which is exploited from natural mineral water, and natural spring water was conducted. A total of 4 different brands of commercial bottled drinking water, and 4 types of spring water from different sources, and tap water from 4 private houses were tested for four index microorganisms, and the microbial quality changes of the water during the storage at room temperature or refrigerated temperature for 7 days. Aerobic plate counts of all of the initial water samples were still within 100 CFU/ml (drinking water standard of Korea). Total coliforms, fecal coliforms, and E. coli were not detected in all of the water samples at initial. However, aerobic plate counts of three types of spring water and three types of bottled drinking water stored at room temperature showed higher levels than the standards in 5 days. Total coliforms were detected in three types of spring water after one day's storage at room temperature, and in one type of bottled drinking water after 5 days' storage. These results indicate that some of the spring water surveyed are not safe to drink, and the spring water and bottled drinking water after opening the lid should not be stored at room temperature, if they are used for drinking.

An Attitude of Residents on College Temporary Housing - Focused on Students in Architectural Design Program - (대학 임시주거 거주학생들의 임시주거에 대한 태도 - 건축학과 학생들을 중심으로 -)

  • Kim, Duk-Su;Kwun, Joon-Bum
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.27 no.2
    • /
    • pp.3-13
    • /
    • 2020
  • The purpose of this study was to analyze the factors negatively affecting college life, to investigate the perception gap between housing types, and to generate preliminary data for increasing residential satisfaction of students who live in temporary housing(e.g., dormitory or one-room). The utilized research methods included a questionnaire survey and an in-depth interview. The college students, especially from other regions, experienced more financial difficulties than others. They managed their tuition and living expense/allowance by parents supports and other sources(e.g., scholarship, arbeit, work in college, loan etc.). The reasons to choose dormitory, as temporary housing, were short distance to college and low costs. In case of one room, independent life was main reason to choose. Gender differences affected to the decision, moving away from present temporary housing. For example, male students preferred an independent life and a short commuting distance, while female students preferred an independent life and a safe life. Thus, considering the origin and gender differences of residents, dormitory planning needed to develop plans allowing independent life and to choose appropriate site for the purpose. In case of planning one room apartment, concerns for safety and landscape were more important than other factors.

A Design Methodology for the Temporary Isolation Room Based on the MERS-Cov Infection Control Guideline - In Case of Temporary Negative Pressure Isolation Room Using Shipping Container - (메르스 감염관리지침에 따른 감염병 임시 격리병동 계획방법에 관한 연구 - 컨테이너를 이용한 음압격리병동을 중심으로 -)

  • Lee, Sang-Hyun;Lee, Jin-Woo
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.19-28
    • /
    • 2017
  • The purpose of this study is to propose a design methodology to build temporary isolation rooms when infectious diseases suddenly occur in a certain region, such as the case of MERS-Cov in South Korea in 2015. Although most big hospitals usually have isolation rooms, they are expensive and dangerous to run such facilities on normal and typical days. To deal with these problems in this research, shipping containers are chosen as devices used to build the temporary isolation rooms near the original hospital. To do so, firstly, a prototype for the temporary isolation room was designed with the three part modules. The first part is for the medical team; the second part including the isolation rooms is for patients; the third part is for medical selection rooms to test the specimens. Secondly, the plan was compared with the MERS-Cov infection control guidelines. Finally this prototype is applied into the Yong-in Yon-sei severance hospital and then evaluated through a CFD simulation using STAR-CCM+(ver.9.06) for checking infectious bacterium movement in this prototype. The result showed that the prototype is effectively safe for patients tested as negative, patients waiting to be tested, and the medical team.

A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room (호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로)

  • Yoon, Hyung Jin;Han, Su Ha
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.

Characteristics of Interior Space and Planning for Elderly Day Care Center in Korea (우리나라 노인주간보호시설의 실내공간 특성과 계획안)

  • 이선주;권오정
    • Journal of Families and Better Life
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Day care center for the elderly is an alternative for community care for frail elderly who need social participation and physical cares and services outside the family. The purpose of this study was to identify the present situation of day care center for the elderly and to suggest desirable interior space plans for elderly day care center. Data were collected by two ways; a mail survey and case studies of existing day care centers. Five cases of day care centers were analyzed to find out Physical and space problems, available programs and services. Also, the staffs in 96 day care centers for the elderly in nationwide were selected for a mail survey and 68.8 percentage of all was collected and analyzed. From the result of case studies, narrow space and lack of accessibility features for wheelchair or other prosthetic devices were the major problems. From the result of a mail survey analysis, the elderly users were over 73 years old, and high proportion had suffered from dementia and apoplexy Also, staffing ration was 1:7 In other words, one staff was caring of 7 old people, and supporting staff was insufficient. Therefore, supportive, therapeutic environment Was more important issue to improve quality of care. Separate program room and outdoor space, lounging space, treatment room by gardening, separate counselling room, bedroom, a simple kitchen unit, staff office, separate physical treatment room, resting room for staff was indicated more necessarily. When priority of planning interior space was safety followed by accessability and convenience, it was also reported that sire of each room was generally narrow. The most serious problem in interior space was the lack and narrowness of space, and accessible features for mobility. Based on the literature review and the findings of this study, two types of floor plans for elderly day care center were suggested;‘a mixed type for the elderly with and without dementia’and‘a separate type for the elderly with dementia.’The main goals for designing interior space for two types of elderly day care center were to provide safe environment, encouraging environment for remaining abilities of users, sanitary environment, therapeutic environment, familiar environment, and socially-encouraging environment. The recommendations for further studies were suggested.

Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement (시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안)

  • Moon, Jae-Seung;Shin, Min-Yong;Ahn, Seong-Cheol;Yoo, Mun-Gon;Kim, Su-Geun
    • Quality Improvement in Health Care
    • /
    • v.20 no.1
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers (급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • This paper investigated pressure differentials in the elevator lobby depending on reference pressures of the pressurizing damper using FDS fire modeling. The results showed the temperatures and pressures in the contained fire room with small leak gaps can increase significantly. Setting reference pressure of the pressurizing dampers to 0 Pa can cause reduction of real pressure differentials and air velocity to resist smoke flow. This would cause smoke movement from fire room to elevator lobby which should be safe area for evacuation.

Regulatory Problems in Radionuclide Therapy and Suggestions for Systematic Improvement (방사성동위원소 치료의 제도적 문제점과 개선)

  • Jeong, Jae-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.2
    • /
    • pp.53-57
    • /
    • 2006
  • Radionuclide therapy has been used for more than 50 years and proved to be a safe and effective modality. However, the patients' right to have the excellent medical service is seriously disturbed by excessive regulations of government institutions such as Korea Institute of Nuclear Safety (KINS), Health Insurance Review Agency (HIRA) and Korea Food and Drug Administration (KFDA). For example, the patients should wait for more than 6 months to have I-131 treatment in many hospitals it is strongly recommended to mitigate the regulations to resonable levels to solve the problems. If HIRA allow the hospitals to charge reasonable rate for radionuclide therapy room, then more hospitals would invest to build the radionuclide therapy rooms and the patients' waiting time would decrease. The waiting time would also decrease, if KINS allow 2 patients to share a radionuclide therapy room. Finally, it is strongly recommended to lower the threshold for approval of new therapeutic radiopharmaceuticals by KFDA, which would allow new effective therapeutic raoiopharmaceuticals to be introduced to clinical practices more easily.

A Case Study on Designing a Console Design Review System Considering Operators' Viewing Range and Anthropometric Data

  • Cha, Woo Chang;Choi, Eun Gyeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.373-383
    • /
    • 2017
  • Objective: The aim of this study is to introduce an operator console design review system suitable for designing and evaluating consoles based on human factor guidelines for a digitalized main control room in an advanced nuclear power plant which has a requirement for anthropometric data usage. Background: The system interface of the main control room in a nuclear power plant has been getting digitalized and consists of various consoles with many information displays. Console operators often face human-computer interactive problems due to inappropriate console design stemming from the perceptual constraints of anthropometric data usage. Method: Computational models with a process of visual perception and variables of anthropometric data are used for designing and evaluating operator consoles suitable for human system interface guidelines, which are used in an advanced nuclear power plant. Results: From the computational model and simulation application, console dimensions and a designing test module, which would be used for designing suitable consoles with safety concerns in a nuclear power plant, have been introduced. Conclusion: This case study may influence employing a suitable design concept with various anthropometric data in many areas with safety concerns and may show a feasible solution to designing and evaluating the safety console dimensions. Application: The results of this study may be used for designing a control room with the human factors requiring a safe working environment.

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.