Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage (아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

Radiation-training system with a custom survey-meter mock-up in a browser-based mixed reality environment

  • Hiroyuki Arakawa;Toshioh Fujibuchi;Kosuke Kaneko;Yoshihiro Okada;Toshiko Tomisawa
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2428-2435
    • /
    • 2024
  • Training for radiation protection and control requires a visual understanding of radiation, which cannot be perceived by the human senses. Trainees must also master the effective use of measuring instruments. Traditionally, such training has exposed trainees to radiation sources. Here, we present a novel e-training strategy that enables safe, exposure-free handling of a radiation measuring tool called a survey meter. Our mixed reality radiation-training system merges the physical world with a digital one. Collaborating with a mixed reality headset (HoloLens 2), this system constructs a mock-up of a survey meter in real-world space. The HoloLens 2 employs a browser-based application to visualize radiation and to simulate/share the use of the survey meter, including its physical movements. To provide a dynamic learning experience, the system adjusts the survey-meter mock-up readings according to the operator's movements, distance from the radiation source, the response time of survey meter, and shielding levels. Through this approach, we expect that trainees will acquire practical skills in interpreting survey-meter readings and gain a visual understanding of radiation in real-world situations.

Intersection Sight Distance Based on Critical Gap at Unsignalized Intersections (임계간격을 이용한 비신호 교차로의 시거 산정에 관한 연구)

  • 이슬기;이용재;김석근
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.5
    • /
    • pp.97-110
    • /
    • 2003
  • The sight distance at unsignalized intersections is the one of the fundamental geometric design elements, and can ensure safety and efficient operations. Despite its importance, little research attention has been directed in Korea compared to developed countries such as European countries, the United States, and Japan. AASHTO ISD policies have been applied to the intersection design in Korea without any revise, which can produce unrealistic and unadoptable design values. Those values are emerged from several reasons because the AASHTO ISD has been calibrated based on the local data. Therefore the ISD hardly takes into account the local characteristics of Korea such as driving behavior. vehicular movement and roadway conditions. The objective of this study is to calculate the appropriate ISD values for unsignalized intersections in the urban area in Korea. In this study, we employed the ISD model of AASHTO(2001), which is based on gap acceptance theory and can account for and take the driving and roadway conditions in Korea into consideration. The approach can also consider the complex driving maneuvers at the intersections in a proper and simple manner. The results in this study show that the ISD design criteria currently used in Korea are more conservative(safer) than those of the USA. In other words, the ISD using field data collected in this study has generally smaller values than those in USA.

Headway Calculation and Train Control Algorithm for Performance Improvement in Radio based Train Control System (무선통신기반 열차제어시스템에서의 운전시격 계산과 간격제어 성능개선을 위한 열차간격제어 알고리즘)

  • Oh, Sehchan;Kim, Kyunghee;Lee, Sung-Hoon;Kim, Ja-Young;Quan, Zhong-Hua
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6949-6958
    • /
    • 2015
  • Radio based train control system performs train safe interval control by receiving in realtime the position information of trains driving in the control area of the wayside system and providing onboard system in each train with updated movement authority. The performance of the train control system is evaluated to calculate the minimum operation headway, which reflects the operation characteristics and the characteristics of the train as well as the interval control performance of the train control system. In this paper, we propose the operation headway calculation for radio based train control system and a new train interval control algorithm to improve the operation headway. The proposed headway calculation defines line headway and station headway by the estimation the safety margin distance reflecting the performance of the train control system. Furthermore the proposed Enhanced Train Interval Control(ETIC) algorithm defines a new movement authority including both distance and speed, and improves the train operation headway by using braking distance occurring inevitably in the preceding train. The proposed operation headway calculation is simulated with Korean Radio-based Train Control System(KRTCS) and the simulated result is compared to improved train interval control algorithm. According to the simulated results, the proposed operation headway calculation can be used as performance indicator for radio based train control system, and the improved train control algorithm can improve the line and station headway of the conventional radio based train control system.

An Analysis on the Prevention Effects of Forward and Chain Collision based on Vehicle-to-Vehicle Communication (차량 간 통신 기반 전방추돌 및 연쇄추돌 방지 효과 분석)

  • Jung, Sung-Dae;Kim, Tae-Oh;Lee, Sang-Sun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.36-43
    • /
    • 2011
  • The forward collision of vehicles in high speed can cause a chain collisions and high fatality rate. Most of the forward collisions are caused by insufficient braking distance due to detection time of driver and safe distance. Also, accumulated detection time of driver is cause of chain collisions after the forward collision. The FVCWS prevents the forward collision by maintaining the safety distance inter-vehicle and reducing detection time of driver. However the FVCWS can cause chain collisions because the system that interacts only forward vehicle has accumulated detection time of driver. In this paper, we analyze forward and chain collisions of normal vehicles and FVCWS vehicles on static traveling scenario. And then, we analyze and compare V2V based FVCWS with them after explaining the system. The V2V FVCWS reduces detection time of driver alike FVCWS as well as remove accumulated detection time of driver by broadcasting emergence message to backward vehicles at the same time. Therefore, the system decrease possibility of forward and chain collisions. All backward normal vehicles and 3~4 backward FVCWS vehicles have possibility of forward and chain collisions in result of analysis. However V2V FVCWS vehicles almost do not chain collisions in the result.

Analysis of the Protection Ratio of GPS System in the Presence of RF Interference Radiated by UWB System (UWB 시스템의 간섭 신호에 대한 GPS 보호 비 분석)

  • Cho, In-Kyoung;Shim, Yong-Sup;Lee, Il-Kyoo;Cho, Hyun-Mook;Hong, Hyun-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.208-213
    • /
    • 2011
  • This paper analyzes potential interference effects of Ultra Wide Band(UWB) on Global Positioning System(GPS) which is providing safety service. For the interference analysis, positioning error method is used to determine the minimum protection distance to meet positioning error of 2.5 m below and Minimum Coupling Loss(MCL) method is used to determine the required protection ratio(I/N) from the protection distance of UWB transmitter and GPS receiver to meet positioning error of 2.5 m below. In a result, the minimum protection distance to meet positioning error of 2.5 m below was about 10 m and the protection ratio to meet positioning error 2.5 m below was -20 dB. The protection ratio proposed in this paper is the same value of the protection ratio of safety service proposed by ITU-R. The obtained protection ratio can be used for the protection standard of domestic GPS system for the safe of life service.

An Experimental Study on Shear Strength of Set Anchors Installed in Plain Concrete (무근콘크리트에 매입된 셋트앵커의 전단내력평가에 관한 실험적 연구)

  • Seo, Seong Yeon;Yang, Young Sung;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.271-283
    • /
    • 2005
  • This paper concerns the prediction of shear capacity, as governed by steel failure and concrete breakout failure, of set anchors installed in plain concrete. For this purpose, the methods to evaluate the shear capacity of the set anchors in concrete are summarized and the experimental data are compared with capacities by the two present methods : the method of ACI349-90 and the Concrete Capacity Design (CCD) method. (1) The constant-0.684 in the steel strength equation of set anchor was determined from shear test data at the 5 percent fractile probability. Consequently, it was concluded that the constant-0.6 and 0.5 in the steel strength equation for steel failure of ACI318-02 and EOTA were safe. The nominal shear strength of set anchor was proposed as following. $V_s=0.684 A_{se}f_{ut}$. (2) The CCD method was considered reasonable in estimating the concrete breakout strength of set anchors. In terms of the CCD method, the nominal concrete breakout strength of set anchor in shear was provided as follows; $V_b=0.609(\frac{\iota}{d_o})^{0.2}\sqrt{d_0}\sqrt{f_c}(c_1)^{1.5}$(N). (3) The CCD method was considered reasonable in estimating the concrete breakout strength for spacing of set anchors. The proposed equation was considered safe in estimating the concrete breakout strength for spacing of set anchors.

Evaluation of Dimensions of Kambin's Triangle to Calculate Maximum Permissible Cannula Diameter for Percutaneous Endoscopic Lumbar Discectomy : A 3-Dimensional Magnetic Resonance Imaging Based Study

  • Pairaiturkar, Pradyumna Purushottam;Sudame, Onkar Shekhar;Pophale, Chetan Shashikant
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.414-421
    • /
    • 2019
  • Objective : To evaluate 3-dimensional magnetic resonance imaging (MRI) of Kambin's safe zone to calculate maximum cannula diameter permissible for safe percutaneous endoscopic lumbar discectomy. Methods : Fifty 3D MRIs of 19 males and 31 females (mean, 47 years) were analysed. Oblique, axial and sagittal views were used for image analysis. Three authors calculated the inscribed circle (cannula diameter) individually, within the neural (original) and bony Kambin's triangle in oblique views, disc heights on sagittal views and root to facet distances at upper and lower end plate levels on axial views and their averages were taken. Results : The mean root to facet distances at upper end plate level measured on axial sections increased from $3.42{\pm}3.01mm$ at L12 level to $4.57{\pm}2.49mm$ at L5S1 level. The mean root to facet distances at lower end plate level measured on axial sections also increased from $6.07{\pm}1.13mm$ at L12 level to $12.9{\pm}2.83mm$ at L5S1 level. Mean maximum cannula diameter permissible through the neural Kambin's triangle increased from $5.67{\pm}1.38mm$ at L12 level to $9.7{\pm}3.82mm$ at L5S1 level. The mean maximum cannula diameter permissible through the bony Kambin's triangle also increased from $4.03{\pm}1.08mm$ at L12 level to $6.11{\pm}1mm$ at L5S1 level. Only 2% of the 427 bony Kambin's triangles could accommodate a cannula diameter of 8mm. The base of the bony Kambin's triangle taken in oblique view (3D MRI) was significantly higher than the root to facet distance at lower end plate level taken in axial view. Conclusion : The largest mean diameter of endoscopic cannula passable through "bony" Kambin's triangle was distinctively smaller than the largest mean diameter of endoscopic cannula passable through "neural" Kambin's triangle at all levels. Although proximity of exiting root to the facet joint is always taken into consideration before PELD procedure, our 3D MRI based anatomical study is the first to provide actual maximum cannula dimensions permissible in this region.

Safety Simulation of Therapeutic I-131 Capsule Using GEANT4 (GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션)

  • Jeong, Yeong-Hwan;Kim, Byung-Cheol;Sim, Cheol-Min;Seo, Han-Kyung;Gwon, Yong-Ju;Han, Dong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • Purpose Iodine (I-131) is one of the most widely used radioactive isotopes for therapeutic in the field of nuclear medicine. Therapeutic I-131 capsule is made out of lead to shield high energy radiation. Accurate dosimetry is necessarily required to perform safe and effective work for relative workers. The Monte Carlo method is known as a method to predict the absorbed dose distribution most accurately in radiation therapy and many researchers constantly attempt to apply this method to the dose calculation of radiotherapy recently. This paper aims to calculate distance dependent and activity dependent therapeutic I-131 capsule using GEANT4. Materials and Methods Therapeutic capsules was implemented on the basis of the design drawings. The simulated dose was determined by generating of gamma rays of energy to more than 364 keV. The simulated dose from the capsule at the distance of 10 cm and 100 cm was measured and calculated in the model of water phantom. The simulated dose were separately calculated for each position of each detector. Results According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of therapeutic I-131 capsule should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated doses turned out to be less than the limit, satisfying the domestic regulation. Conclusion These simulation results may serve as useful data in the prediction of hands dose absorbed by I-131 capsule handling. GEANT4 is considered that it will be effectively used in order to check the radiation dose.

  • PDF

Evaluation on Geological Structures to Secure Long-term Safety of Nuclear Facility Sites (원자력시설물 부지의 장기적 안전성 확보를 위한 지질구조 평가)

  • Jin, Kwangmin;Kim, Young-Seog
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.149-166
    • /
    • 2018
  • Many large earthquakes have continuously been reported and resulted in significant human casualties and extensive damages to properties globally. The accident of Fukushima nuclear power plant in Japan was caused by a mega-tsunami, which is a secondary effect associated with the Tohoku large earthquake (M=9.0, 2011. 3. 11.). Most earthquakes occur by reactivation of pre-existing active faults. Therefore, the importance of paleoseismological study have greatly been increased. The Korean peninsula has generally been considered to be a tectonically stable region compared with neighboring countries such as Japan and Taiwan, because it is located on the margin of the Eurasian intra-continental region. However, the recent earthquakes in Gyeongju and Pohang have brought considerable insecurity on earthquake hazard. In particular, this region should be secure against earthquake, because many nuclear facilties and large industrial facilities are located in this area. However, some large earthquakes have been reported in historic documents and also several active faults have been reported in southeast Korea. This study explains the evaluation methods of geological structures on active fault, fault damage zone, the relationship between earthquake and active fault, and respect distance. This study can contribute to selection of safe locations for nuclear facilities and to earthquake hazards and disaster prevention.