• Title/Summary/Keyword: runoff volume

Search Result 320, Processing Time 0.021 seconds

Runoff Characteristics Change of a Basin under Urbanization (도시화 진행에 따른 유역 유출특성 변화에 관한 연구)

  • Son, Kwang-Ik;Kim, Min-Chol
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.89-93
    • /
    • 2010
  • It is well known that the drastic change of hydrological characteristics of an urbanized basin causes severe runoff, sediment yield, and peak flow. High vulnerability of urban flood disasters is caused by land-use change and development of a basin. A typical site suffering urbanization was selected and the experimental site has being operated last three years. Hydrological and hydraulic characteristics of the urbanizing basin were examined by observation of runoff, sediment loads and precipitation with T/M. The effects of land-use change were analyzed by examination of the hydrological characteristics, such as run-off ratio (runoff volume/rainfall volume), sediment yields. Runoff coefficient of rational equation was increased as basin was urbanized. Suspended sediment yields due to a urban development activities were raised almost 10 times compare to undisturbed condition for small runoff less than 1 cms. Meanwhile, no big change could be detected for bed loads.

Characteristics of Non-point Pollutants from the Road Runoff (2): Heavy Metals and Pathogens (도로노면 유출수의 비점오염원 배출 특성(2): 중금속 및 병원성 미생물)

  • Park, Sangwoo;Oh, Jeill;Choi, Younghwa;Kim, Jonghwa;Ha, Jaewon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.235-242
    • /
    • 2007
  • Road runoff water includes various heavy metals (zinc, Zn; lead, Pb; copper, Cu; chrome, Cr; cadmium, Cd; etc.) and pathogens (E-coli and coliform). Since these pollutants are significantly harmful to human beings and have negative impact on water streams, numerous studies have been conducted to determine the characterization of these non-point pollutants from road runoff water. However, since these non-point pollutant concentrations vary depending on road traffic, road construction, and road maintenance, measurement of pollutant loadings in different site is necessary to estimate the effect of road runoff water on drinking water source. The objective of this study was to examine the quality of road runoff water from a city bridge in Seoul, Korea. This study was conducted for two years to assess annual discharge pollution loads. In this study, five key heavy metals (Zn, Pb, Cu, Cr, and Cd) and two pathogens (E-coli and coliform) were measured at 18 different events. The pollutant load mass transported was always higher than the corresponding runoff volume for Zn, Cu, and Cd, while Pb and Cr showed similar values between the load mass transported and the corresponding runoff volume. The event mean concentrations were Zn (0.908 mg/L), Pb (0.092 mg/L), Cu (0.141 mg/L), Cr (0.023 mg/L), and Cd (0.006 mg/L). Like Zn, Cu, and Cd, E-coli and coliform values (relatively high in Summer and Fall) are higher at the beginning of each event and decrease afterwards.

L-THIA/NPS to Assess the Impacts of Urbanization on Estimated Runoff and NPS Pollution (도시화에 따른 유출과 비점원 오염 영향을 평가하기 위한 L-THIA/NPS)

  • Kyoung-Jae Lim;Bernard A. Engel;Young-Sug Kim;Joong-Dae Choi;Ki-Sung Kim
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.4
    • /
    • pp.78-88
    • /
    • 2003
  • The land use changes from non-urban areas to urban areas lead to the increased impervious areas, consequently increased direct runoff and higher peak runoff. Urban areas have also been recognized as significant sources of Nonpoint Source (NPS) pollution, while agricultural activities have been known as the primary sources of NPS pollution. Many features of the L-THIA/NPS GIS, L-THIA/NPS WWW system have been enhanced to provide easy-to-use system. The L-THIA model was applied to the Little Eagle Creek (LEC) watershed in Indiana to evaluate the accuracy of the model. The L-THIA/NPS GIS estimated yearly direct runoff values match the direct runoff separated from U.S. Geological Survey stream flow data reasonably. The $R^2$ and Nash-Sutcliffe values are 0.67 and 0.60, respectively. The L-THIA estimated runoff volume and total nitrogen loading for each land use classification in the LEC watershed were computed. The estimated runoff volume and total nitrogen loading in the LEC watershed increased by 180% and 270% for the 20 years. Urbanized areas -"Commercial", "High Density Residential", and "Low Density Residential"- of the LEC watershed made up around 68% of the 1991 total land areas, however contributed more than 92% of average annual runoff and 86% of total nitrogen loading. Therefore, it is essential to consider the impacts of land use change on hydrology and water quality in land use planning of urbanizing watershed.nning of urbanizing watershed.

The furulamelllal study in order to obtain the hydrological design basis for hydrological structures in Korea (Run ofl estimate and Flood part) (한국에 있어서 제수문구조물의 설계의 기준을 주기 위한 수문학적 연구(류거, 홍수 편))

  • 박성우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.8 no.1
    • /
    • pp.1011-1034
    • /
    • 1966
  • This thesis is the final report which has long been studied by the author to obtain the design basis for various hydrological constructions with the specific system suitable to the natural environmental conditions in Korea. This report is divided into two parts: one is to estimate runoff volume from watersheds and the other to estimate the peak discharge for a single storm. According to the result of observed runoff record from watersheds, it is known that Kajiyama formula is useful instrument in estimating runoff volume from watersheds in this country. But it has been found that this formula shows us 20-30% less than the actual flow. Therefore, when wihed to bring a better result, the watershed characteristics coefficient in this formula, that is, f-value, should be corrected to 0.5-0.8. As for the method to estimate peak discharge from drainage basin, the author proposes to classify it in two ways; one is small size watershed and the other large size watershed. The maximum -flood discharge rate $Q_p$ and time to peak Pt obtained from the observed record on the small size watershed are compared by various methods and formulas which are based upon the modern hydrological knowledge. But it was fou.d that it. was not a satisfied result. Therefore, the author proposes. tocomputate $Q_p$, to present 4.0-5.0% for the total runoff volume ${\Sigma}Q$.${\Sigma}Q$ is computed under the assumption of 30mm 103s in watershed per day and to change the theoritical total flow volume to one hour dura tion total flow rate when design daily storm is given. Time to peak Pt is derived from three parameters which are u,w,k. These are computed by relationship between total runoff volume (ha-m unit)and $Q_p$. (C.M.S. unit). Finally, the author checked out these results obtained from 51 hydrographs and got a satisfied result. Therefore the author suggested the model of design dimensionless unit-hydrograph. And the author believes that this model will be much available at none runoff record river site. In the large size watersheds in Korea when the maximum discharge occurs, the effective rainfall is two consequtive stormy days. So the loss in watershed was assutned as 6Omm/2days,and the author proposed 3-hour-daration hydrograph flow distribution percentage. This distribution percentage will be sure to form the hydrograph coordinate.

  • PDF

A Study on the Variation of Runoff and Travel Time in Urban Stream due to Watershed Development (유역개발에 따른 도시하천에서의 유출량 및 도달시간 변화에 관한 연구)

  • 서규우;배덕효
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.207-216
    • /
    • 1996
  • The subject research attempts to evaluate the variations of total runoff volume, peak flow, and travel time depending on the urbanhization, return periods and rainfall patterns under the situations that the preparation of a large residential site at the lowland areas of the downstream of Dongsu stream in Bupyung-Gu, Incheon city is progressed and the area will be eventually fully developed. The ILLUDAS model was used for the runoff analyses based on 3 differend steps of urbanization and 4 different types of Huff's quantile according to rainfall patterns is Huff's 4 quantile, Huff's 2 quantile, Huff's 3 quantile and Huff's 1 quantile. Under the 80 and 90 % of urbanization to the 70% of urbanization, the mean increasing ratio of total runoff volume for each case is 3.5 and 5.5 %, that of peak flow is 4.2 and 8.8%, and the mean decreasing ratio of travel time is 4.4 and 10.1%, respectively. The mean increasing ratio of total runoff volume according to the return periods is 3.0 and 5.4%, that of peak flow is 3.9 and 8.0% under the same conditions of urbanization.

  • PDF

An Hybrid Approach for Designing Detention and Infiltration-based Retentions to Promote Sound Urban Hydrologic Cycle (도시 물 순환 건전성을 위한 유수지와 침투기반 저류지의 복합설계기법)

  • Choi, Chi-Hyun;Choi, Dae-Gyu;Lee, Jae-Kwan;Kim, Sang-Dan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • This article proposes a hybrid approach involved in determining the size of stormwater control facilities as part of a very large scale urban retrofit project. The objective of the proposed hybrid approach is to restore the pre-development hydrologic cycle. Firstly, an appropriate IETD is determined to isolate single storm events from the continuous rainfall record. Then, using the NRCS-CN method, direct runoff and infiltration volume are computed for every storm events. Long-term statistics of direct runoff and infiltration volume are analyzed in each case of pre-development, post development, post development with detention only, and post-development with the proposed hybrid approach. In order to preserve long-term statistics of direct runoff and infiltration volume in the case of pre-development, the size of detention and infiltration-based retention are estimated using the genetic algorithm. The result shows that the proposed hybrid approach is very useful for restoring statistics of natural direct runoff and infiltration volume.

A Study on the Outlet Drain Discharge from Paddy Field (논의 배수물꼬의 유량에 관한 기초연구)

  • 최진규;김현영;손재권
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

Runoff Characteristics by Urbanization in the Mushim Stream Watershed using HEC-BMS (HEC-HMS를 활용한 무심천 유역내 도시화에 의한 유출 특성)

  • Yoon, Seok-Hwan;Lee, Jong-Hyeong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.3
    • /
    • pp.43-54
    • /
    • 2004
  • For a given watershed that consists of urbanized areas, it was essential to predict how the runoff characteristics, such as runoff peak and volume, and travel time, change with time far planning and designing various kinds of hydraulic facilities with given recurrence interval. In this study, Mushim stream watershed was simulated using HEC-HMS model to get runoff characteristics of an urbanization basin. The results was showed that runoff was increased $1794.20{\sim}2104.65\;m^{3}/s$> and $1751.90{\sim}1961.30\;m^{3}/s$ according to the increased of rainfall and CN value recurrence interval in years. Observed storm was increased $497.91{\sim}581.71\;m^{3}/s$ and $506.57{\sim}537.01\;m^{3}/s$ for increased of CN value and impervious area. This paper is also possible to evaluate the effect of urbanization quantitatively.

Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff

  • Yu, Jianghua;Yi, Qitao;Kim, Young-Chul
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.262-269
    • /
    • 2009
  • This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a ${\varphi}7.5$ cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes ($D_u/D_i$), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow ($TSS_{over/in}$) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow ($TSS_{under/in}$) increased. There was no visible difference in the $TSS_{over/in}$ with increasing $D_u/D_i$ ratio, but the $TSS_{under/in}$ decreased sharply. The particle removal efficiency was mainly affected by the particle size.

A Study of the Variation of Runoff Characteristics Depending upon Installation of the Groundwater Recharge Facilities (인공함양시설 설치에 따른 유출특성 변화에 관한 연구)

  • Choi, Gye-Woon;Kim, Young-Kyu;Jeoung, Kee-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.27-34
    • /
    • 2004
  • In this paper, in order to analyse the variation of runoff characteristics depending upon installation of the groundwater recharge facilities, the experiment basin was prepared and the ratio of infiltration and runoff volume were observed in the rainfall events. For the rainfall analysis, 4 types of rainfall events were examined during July 11${\sim}$July 17, 2004. The results show that the mean ratio of infiltration was 89.39% and the mean ratio of runoff was 10.61%. For the artificial rainfall events, which are in the range of rainfall intensities between 60mm/hr and 100mm/hr, all the rainfall volume was infiltrated through the groundwater recharging basin. However, it is necessary to be careful for the long term rainfall, the runoff can be occurred based on the groundwater table.