• Title/Summary/Keyword: run off

Search Result 369, Processing Time 0.032 seconds

Estimation of the Relative Risk of the Elderly with Different Evacuation Velocity in a Toxic Gas Leakage Accident (독성물질 누출 시 대피 속도 차이에 따른 고령자의 상대적 위험도 산정)

  • Lee, H.T.;Kwak, J.;Park, J.;Ryu, J.;Lee, J.;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.13-21
    • /
    • 2019
  • Leakage accidents in businesses dealing with hazardous chemicals can have a great impact on the workers inside the workplace, as well as residents outside the workplace. In fact, there were cases where hazardous chemicals leaked from many businesses. As a result, the Chemicals Control Act(CCA) was enacted in 2015, the Ministry of Environment introduced an Off-site Risk Assessment(ORA). The purpose of the ORA is to secure safety from the installation of the design of the workplace facilities so that chemical accidents of hazardous chemical handling facilities do not cause human or physical damage outside the workplace. In general, the ORA qualitatively determines where a protected facility is within the scope of the accident scenario. However, elderly who belong to the sensitive group is more sensitive than the general group under the same chemical accident effect, and the extent of the damage is serious. According to data from the Korea National Statistic Office, the number of elderly people is expected to increase steadily. Therefore, a quantitative risk analysis considering the elderly is necessary as a result of a chemical accident. In this study, accident scenarios for 14 locations were set up to perform emergency evacuation due to toxic gas leakage of Cl2(Chlorine) and HF(Hydrogen Fluoride), and the effects of exposure were analyzed based on the evacuation velocity difference of age 20s and 60s. The ALOHA(Areal Locations of Hazardous Atmospheres) program was used to calculate the concentration for assessing the effects. The time of exposure to toxic gas was calculated based on the time it took for the evacuation to run from the start point to the desired point and a methodology was devised that could be applied to the risk calculation. As a result of the study, the relative risk of the elderly, the sensitive group, needs to be determined.

Business Method Developing a "Walking" Navigator for Street Shoppers (거리쇼핑용 보행자 네비게이션의 비즈니스 모델 개발)

  • Lee, Jong-Deok;Hwang, Kee-Yeon
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.3
    • /
    • pp.129-141
    • /
    • 2008
  • Portable navigation markets grew up to 95% last year. This study aims to develop a business model for pedestrian-oriented portable navigator for street shoppers. Related previous studies developed successfully the alogrithm for a portable navigator, and the current study seeks for diverse ways to turn this system into a new type of on & off line-based LBS business. The business model proposed in this study adopted two different approaches of benefit yields based on the structural analysis of so-called Wanavi navigation system. One is segmented approach seeking for benefits from each individual system component such as communication network, contents, and platform. The other approach is to run the business by integrating relevant system componts in every possible way to attract customers to this portable navigator. The purpose of this proposal is not limited to activate emerging walking navigator markets, but to aim at creating idealistic free market system where all the shoppers are furnished complete market information to the fullest extent when they go on shopping.

A STUDY ON THE PARAMETER ESTIMATION OF SNYDER-TYPE SYNTHETIC UNIT-HYDROGRAPH DEVELOPMENT IN KUM RIVER BASIN

  • Jeong, Sang-man;Park, Seok-Chae;Lee, Joo-Heon
    • Water Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.219-229
    • /
    • 2001
  • Synthetic unit hydrograph equations for rainfall run-off characteristics analysis and estimation of design flood have long and quite frequently been presented, the Snyder and SCS synthetic unit hydrograph. The major inputs to the Snyder and SCS synthetic unit hydrograph are lag time and peak coefficient. In this study, the methods for estimating lag time and peak coefficient for small watersheds proposed by Zhao and McEnroe(1999) were applied to the Kum river basin in Korea. We investigated lag times of relatively small watersheds in the Kum river basin in Korea. For this investigation the recent rainfall and stream flow data for 10 relatively small watersheds with drainage areas ranging from 134 to 902 square kilometers were gathered and used. 250 flood flow events were identified along the way, and the lag time for the flood events was determined by using the rainfall and stream flow data. Lag time is closely related with the basin characteristics of a given drainage area such as channel length, channel slope, and drainage area. A regression analysis was conducted to relate lag time to the watershed characteristics. The resulting regression model is as shown below: ※ see full text (equations) In the model, Tlag is the lag time in hours, Lc is the length of the main river in kilometers and Se is the equivalent channel slope of the main channel. The coefficient of determinations (r$^2$)expressed in the regression equation is 0.846. The peak coefficient is not correlated significantly with any of the watershed characteristics. We recommend a peak coefficient of 0.60 as input to the Snyder unit-hydrograph model for the ungauged Kum river watersheds

  • PDF

Real-Propellant Test of a Turbopump for a 30-Ton Thrust Level of Liquid Rocket Engine (30톤급 액체로켓엔진용 터보펌프 실매질시험)

  • Hong, Soon-Sam;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.3
    • /
    • pp.20-26
    • /
    • 2009
  • Turbopump test for a 30-ton-thrust liquid rocket engine was carried out using real-propellant. Liquid oxygen, kerosene, cold hydrogen gas were used for the oxidizer pump, the fuel pump, and the turbine, respectively. The turbopump was reliably operated at the design and off-design conditions and the performance requirements were satisfied, which implies that the turbopump development at the engine subsystem level is successfully accomplished in the point of performance validation. This paper presents the results of a test where the turbopump was run for 75 seconds at three operating modes. In terms of performance characteristics of pumps and turbine, the results of turbopump assembly test using real-propellant showed a good agreement with those of the turbopump component tests using simulant working fluid.

Functional Drainage Evaluation of Block Paving through the Usage of Sludge and Wheel Tracking Test (슬러지 투입 및 휠트랙킹 시험을 이용한 블록 포장의 기능적 투수평가)

  • Lee, Sang-Yum;Jung, Hoon-Hee;Mun, Sung-Ho;Park, Dae-Geun;Park, Kyong-Min
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.31-38
    • /
    • 2011
  • As the percentage of permeable ground is reduced due to the increased impermeable roads of major cities, a heat island phenomenon can be dominantly observed, resulting in increased temperature. In addition, rainfall that would have been naturally absorbed and retained by the permeable ground is overflowed due to large volumes of run-off water, resulting in more sewer failures and increased erosion. In terms of permeable pavement system, block paving has been used anywhere as well as provides many years of service. The permeable block paving is an effective alternative to the more traditional asphalt or plain concrete for minor roads; furthermore, it looks a lot better than other pavements. In this study, the functional drainage evaluation of block paving was carried out, considering the usage of experimental sludge and wheel tracking test, in order to simulate the field condition of roads.

Development of a Modified Standardized Precipitation Index by Considering Effects of the Dry Period and Rainfall (무강수일수와 강우효과를 고려한 개선된 표준강수지수 개발)

  • Lee, Jun-Won;Kim, Gwang-Seob
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.4
    • /
    • pp.409-418
    • /
    • 2012
  • A modified standardized precipitation index was developed by considering the length of dry period and surface run-off effect. The official reports and newspapers on drought from 1973 to 2009 were quantified to evaluate drought indices. The developed index was evaluated using the receiver operating characteristic analysis. In order to suggest improved drought index, we cut the precipitation amount that may do not contribute the mitigation of drought and weight dry period by considering cumulative distribution, decile distribution of dry periods. Drought detection capability of the suggested index has improved by weighting of dry period effects and considering precipitation amounts contributing drought mitigation.

Flood Inundation Analysis in Urban Area Using XP-SWMM (XP-SWMM 모형을 이용한 도심지역 침수해석)

  • Kim, Jinsu;Lee, Wonho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Current domestic research is to demonstrate the effectiveness and efficiencies of flood prevention measures through one-dimensional numerical analysis and this study's object is to help water managers to make the efficient decisions by applying the two-dimensional urban run off model XP-SWMM model in the flooded area and comparing with the flood prevention measures. Statistics were analyzed, based on the data collected from Cheongju Weather Service from 1967 to 2011 for 45 years. 50 years Flood frequency simulations of water flow capacity analysis of the target area for flooded areas $539,548m^2$, inundation depth 1.0 m, was analyzed by inundation time of 48 minutes. When comparing with the constructions of bypass road and underground storage facilities to increase the water flow capacity of A1 small drainage areas as flood protection, if you install a batching target underground detention basin with a capacity of $13,500m^3$, it is expected that the flood by rainfall with frequency of 50 years will be resolved completely. In preparation for extreme weather in the future flood mitigation measures, underground storage tank installation is considered a better efficient way.

The Consume Characteristic of Musicals through Korea Performing Arts Box Office Information System(KOPIS) (공연예술통합전산망(KOPIS)을 통한 뮤지컬 소비 특징)

  • Shin, Jong-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.6
    • /
    • pp.241-255
    • /
    • 2020
  • The purpose of this study is to analyze musical performances with the use of performance booking information from 2017 to 2019 which was obtained in Korea performing Arts Box Office Information system (KOPIS), and to make suggestions of Korean musical performances. Based on the data of KOPIS, relevant studies, internet based information, news articles, and magazines, musical performances were analyzed. In addition, the previous data of KOPIS and the data of the Broadway League were analyzed. The analysis results are as follows. Firstly, it is necessary to concentrate on Korean mid-sized theatre musical performances. Secondly, producers need to open their production costs invested in performances transparently. Thirdly, Off-Broadway system needs to be introduced after being modified in consideration of Korean situations. Thirdly, it is necessary to make long-run performances in order to achieve commercial success. Fifthly, it is necessary to make a bold attempt of theatre for performances just as in Broadway.

Assessment of damages on a RC building after a big fire

  • Ada, Mehmet;Sevim, Baris;Yuzer, Nabi;Ayvaz, Yusuf
    • Advances in concrete construction
    • /
    • v.6 no.2
    • /
    • pp.177-197
    • /
    • 2018
  • This paper presents a case study about the damages on the structural elements of a cast in place reinforced concrete (RC) building after a big fire which was able to be controlled after six hours. The fire broke off at the $2^{nd}$ basement floor of the building, which has five basements, one ground, and two normal floors. As a result of intensely stocked ignitable materials, it spread out to the all of the upstairs. In visual inspection, most of the typical fire damages were observed (such as spalling, net-like cracks, crumbled plasters, bared or visible reinforcement). Also, failures of the $2^{nd}$ basement columns were encountered. It has been concluded that the severity failures of the columns at the $2^{nd}$ basement caused utterly deformation of the building, which is responsible for the massive damages on the beam-column connections. All of the observed damages were categorized related to the types and presented separated regarding the floors. Besides to the visual inspection, the numerical analysis was run to verify the observed damaged on the building for columns, beams, and the connection regions. It is concluded from the study that several parameters such as duration of the fire, level of the temperature influence on the damages to the RC building. Also, it is highlighted by the study that if the damaged building is considered on the overall structural system, it is not able to satisfy the minimum service requirements neither gravity loads nor earthquake conditions.

Optical(Interferometric) Measurements of Vapor Deposition Growth Rate and Dew Points in Combustion Gases (빛의 간섭현상을 이용한 증기용착 성장속도 측정법의 실험적 연구)

  • 김상수;송영훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.343-348
    • /
    • 1986
  • An optical interference method was developed for measuring rapidly growing and evaporating liquid condensate films (e.g., Na$_{2}$SO$_{4}$, $K_{2}$SO$_{4}$) on solid surface exposed to flowing combustion product gases at film thicknesses well below the onset of complications due to run-off. To develop this optical system, this study investigated the optical parameters (e.g., polarization state, incident angle, target roughness, etc.) Trends for the Na$_{2}$SO$_{4}$(l) and $K_{2}$SO$_{4}$(l) deposition rates as a function of target temperature using this optical measuring system agree with the theoretical prediction of the vapor deposition. This study was able to extend the experimental range for vapor plus condensed phase transport and deposition. While previously unable to measure the evaporation rates interferometrically, these rates are estimated from the results of the investigation of polarization states.