• 제목/요약/키워드: rubber isolator

검색결과 97건 처리시간 0.022초

상대강성비를 고려한 지진격리교량의 응답특성 (Seismic Responses of Isolated Bridges Considering the Relative Stiffness Ratio)

  • 서현우;김남식;정진환
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1340-1346
    • /
    • 2005
  • In this study, based on shaking table test results on a seismically isolated bridge model, an inelastic numerical model is refined by using Bouc-Wen model representing the hysteretic behavior of isolators. Seismic responses of isolated bridges are numerically investigated varying with relative stiffness ratio(RSR), which is a ratio of the effective stiffness of isolator to the lateral stiffness of bridge pier, From the results, it is found that an adequate range of relative stiffness ratio could be defined for seismic design of isolated bridges without considering the flexibility of piers.

지진격리된 철골구조물의 진동대 실험 (Shaking Table Tests of Base-Isolated Steel Frame)

  • 윤정방
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.136-143
    • /
    • 1997
  • 본 연구에서는 철골구조물을 대상으로 지진격리(Base-Isolation)를 사용하였을 때의 진동감소 효과를 분석하기 위하여 지진하중에 대한 진동대 실험을 수행하였다. 실험 대상구조물은 $\frac{1}{4}$축소모형의 3층 철골구조물이며, 입력지진은 여러 계측기록과 UBC 설계스펙트럼으로부터 3가지 지반조건에 대하여 작성한 인공지진기록을 사용하였다. 축소 실험모형은 기초가 고정된 일반적인 철골구조물과 적층고무받침(Laminated Rubber Bearing) 형식의 지진격리장치(Base Isolator)를 사용한 구조물을 동시에 설치하여 그 지진응답을 비교 관찰하였다. 대부분의 하중하에서 지진격리장치가 사용된 철골구조물의 경우에 지진응답이 현저히 감소하는 것을 알 수 있으나, 장주기파의 성분이 강한 지반운동에 대해서는 오히려 지진응답이 증가하였다. 그러나 여러 지반조건에 대하여 UBC 시방서에서 규정한 설계하중에 대하여는 진동감소효과가 우수함을 보인다.

  • PDF

교각의 강성을 고려한 지진격리교량의 응답특성 평가 (Evaluation of Seismic Responses of Isolated Bridges Considering the Flexibility of Piers)

  • 서현우;김남식;정진환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.662-665
    • /
    • 2004
  • In this paper, based on shaking table test results on a seismically isolated bridge model, an inelastic numerical model is refined by using Bouc-Wen model representing the hysteretic behavior of isolators. Seismic responses of isolated bridges are numerically investigated varying with relative stiffness ratios, which is a ratio of the effective stiffness of isolator to the lateral stiffness of bridge pier. From the results, it is found that an adequate range of relative stiffness ratio could be defined for seismic design of isolated bridges without considering the flexibility of piers.

  • PDF

고무마운트를 통한 장비의 고체음 전달에 관한 연구 (Study on the Structure-borne Sound Transmission of a Machine through Rubber Mounts)

  • 김봉기;김재승;김현실;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.655-660
    • /
    • 2000
  • Machines on board a ship are mounted on decks and transmit its structure-borne sound to the deck through resilient mounts. To predict the ship noise generated by the structure-borne sound of the machine, It is necessary to estimate the vibration level of the base structure. In this paper, a simple dynamic model is considered for vibration isolation systems consisting of a source, an isolator, and a base structure. The high frequency mobilities of the simple base structure are reviewed and wave effects in the mount are discussed in relation to isolation performance.

  • PDF

Piecewise exact solution for analysis of base-isolated structures under earthquakes

  • Tsai, C.S.;Chiang, Tsu-Cheng;Chen, Bo-Jen;Chen, Kuei-Chi
    • Structural Engineering and Mechanics
    • /
    • 제19권4호
    • /
    • pp.381-399
    • /
    • 2005
  • Base isolation technologies have been proven to be very efficient in protecting structures from seismic hazards during experimental and theoretical studies. In recent years, there have been more and more engineering applications using base isolators to upgrade the seismic resistibility of structures. Optimum design of the base isolator can lessen the undesirable seismic hazard with the most efficiency. Hence, tracing the nonlinear behavior of the base isolator with good accuracy is important in the engineering profession. In order to predict the nonlinear behavior of base isolated structures precisely, hundreds even thousands of degrees-of-freedom and iterative algorithm are required for nonlinear time history analysis. In view of this, a simple and feasible exact formulation without any iteration has been proposed in this study to calculate the seismic responses of structures with base isolators. Comparison between the experimental results from shaking table tests conducted at National Center for Research on Earthquake Engineering in Taiwan and the analytical results show that the proposed method can accurately simulate the seismic behavior of base isolated structures with elastomeric bearings. Furthermore, it is also shown that the proposed method can predict the nonlinear behavior of the VCFPS isolated structure with accuracy as compared to that from the nonlinear finite element program. Therefore, the proposed concept can be used as a simple and practical tool for engineering professions for designing the elastomeric bearing as well as sliding bearing.

Retrofitting of vulnerable RC structures by base isolation technique

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Ahmmad, Rasel;Darain, Kh. Mahfuz ud
    • Earthquakes and Structures
    • /
    • 제9권3호
    • /
    • pp.603-623
    • /
    • 2015
  • The scale and nature of the recent earthquakes in the world and the related earthquake disaster index coerce the concerned community to become anxious about it. Therefore, it is crucial that seismic lateral load effect will be appropriately considered in structural design. Application of seismic isolation system stands as a consistent alternative against this hazard. The objective of the study is to evaluate the structural and economic feasibility of reinforced concrete (RC) buildings with base isolation located in medium risk seismic region. Linear and nonlinear dynamic analyses as well as linear static analysis under site-specific bi-directional seismic excitation have been carried out for both fixed based (FB) and base isolated (BI) buildings in the present study. The superstructure and base of buildings are modeled in a 3D finite element model by consistent mass approach having six degrees of freedom at each node. The floor slabs are simulated as rigid diaphragms. Lead rubber bearing (LRB) and High damping rubber bearing (HDRB) are used as isolation device. Change of structural behaviors and savings in construction costing are evaluated. The study shows that for low to medium rise buildings, isolators can reduce muscular amount of base shears, base moments and floor accelerations for building at soft to medium stiff soil. Allowable higher horizontal displacement induces structural flexibility. Though incorporating isolator increases the outlay, overall structural cost may be reduced. The application of base isolation system confirms a potential to be used as a viable solution in economic building design.

Response modification factors of concrete bridges with different bearing conditions

  • Zahrai, Seyed Mehdi;Khorraminejad, Amir;Sedaghati, Parshan
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.185-196
    • /
    • 2019
  • One of the shortcomings of seismic bridge design codes is the lack of clarity in defining the role of different seismic isolation systems with linear or nonlinear behavior in terms of R-factor. For example, based on AASHTO guide specifications for seismic isolation design, R-factor for all substructure elements of isolated bridges should be half of those expressed in the AASHTO standard specifications for highway bridges (i.e., R=3 for single columns and R=5 for multiple column bent) but not less than 1.50. However, no distinction is made between two commonly used types of seismic isolation devices, i.e., elastomeric rubber bearing (ERB) with linear behavior, and lead rubber bearing (LRB) with nonlinear behavior. In this paper, five existing bridges located in Iran with two types of deck-pier connection including ERB and LRB isolators, and two bridge models with monolithic deck-pier connection are developed and their R-factor values are assessed based on the Uang's method. The average R-factors for the bridges with ERB isolators are calculated as 3.89 and 4.91 in the longitudinal and transverse directions, respectively, which are not in consonance with the AASHTO guide specifications for seismic isolation design (i.e., R=3/2=1.5 for the longitudinal direction and R=5/2=2.5 for the transverse direction). This is a clear indicator that the code-prescribed R-factors are conservative for typical bridges with ERB isolators. Also for the bridges with LRB isolators, the average computed R-factors equal 1.652 and 2.232 in the longitudinal and transverse directions, respectively, which are in a good agreement with the code-specified R-factor values. Moreover, in the bridges with monolithic deck-pier connection, the average R-factor in the longitudinal direction is obtained as 2.92 which is close to the specified R-factor in the bridge design codes (i.e., 3), and in the transverse direction is obtained as 2.41 which is about half of the corresponding R-factor value in the specifications (i.e., 5).

LRB 면진장치가 설치된 엑스트라도즈드교의 지진위험도 평가 (Seismic Risk Assessment of Extradosed Bridges with Lead Rubber Bearings)

  • 김두기;서형렬;이진학
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.155-162
    • /
    • 2006
  • 본 연구에서는 납면진받침(LRB)이 설치된 중경간 엑스트라도즈드교에서 교각의 파손, 상부구조의 이동변위, 그리고 케이블의 항복에 대한 지진위험도를 평가하였다. 지진위험도는 다수의 지진자료를 이용하여 지진에 대한 구조적 취약성을 평가한 지진취약도와 지진재해지도를 이용하여 해당지역에서의 지진재해도를 산정하여, 이들을 조합함으로써 평가할 수 있었다. 지진시 교각에서 소성힌지의 발생을 고려하기 위해 SAP2000을 사용하여 비선형 지진해석을 수행하였다. 지진자료는 암반노두에서 설계응답스펙트럼을 만족하는 인공지진을 작성한 후, SHAKE91을 사용하여 해당지역의 지반증폭효과를 고려하여 지진 가속도 시간이력을 구하여 사용하였다. 교각의 비선형 응답은 연성도를 사용하여 나타내었고, 2선형 직선의 모멘트-곡률 곡선으로 작성하였다. 본 연구에서는 대수정규분포함수로 지진취약도를 표현하였으며, 한반도를 대상으로 작성된 지진재해지도를 이용하여 지진재해도를 산정하였다. 해석결과 엑스트라도즈드교에서는 케이블과 거더보다는 교각하단에서 면진장치가 더 효과적인 것을 알 수 있었다.

납고무받침을 이용한 스테인리스 물탱크 내진성능에 관한 해석적 연구 (A Analytical Study on Seismic Performance of Stainless Water Tank using Lead Rubber Bearing)

  • 김후승;오주;정희영
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.230-236
    • /
    • 2018
  • 최근 국내에서도 규모 5.0 이상의 지진이 발생하여 구조물의 내진 안전성에 대한 관심이 증가하고 있다. 특히, 물을 저장하는 시설은 지진에 의해 손상 및 파손이 될 경우, 누수로 식수 및 용수가 부족하게 될 뿐만 아니라 화재 진압의 어려움이 야기되므로 지진에 대한 안전성을 만족하여야 한다. 본 연구에서는 기초와 탱크사이에 납고무받침을 고려하여 지진에 대한 물탱크의 내진성능을 향상시키고자 한다. 이를 위해 기존 콘크리트 기초에 설치 가능하도록 납고무받침을 설계하였다. 물탱크에 대하여 유체-구조물 상호작용을 고려하기 위하여 ANSYS를 활용하여 모델링을 수행하였으며 정수압과 4개의 지진파를 이용한 동수압을 고려하였다. 만수위 2.5m의 정수압이 작용하는 경우에 대하여 정적 해석을 수행한 결과, 면진 적용여부와 상관없이 동일한 응력이 발생하였다. 정수압과 동수압을 동시에 고려했을 때, 면진 물탱크는 전반적으로 지진력 감소가 이루어졌지만 일반적인 구조면진과 비교했을 때 감쇠율이 다소 낮은 것으로 나타났다. 이는 물탱크 중량이 면진 강성보다 매우 작아서 나타난 결과로 판단되며, 향후 물탱크 내진성능 평가에 기초 자료로 활용될 것으로 기대된다.

A comparison of the effect of SSI on base isolation systems and fixed-base structures for soft soil

  • Karabork, T.;Deneme, I.O.;Bilgehan, R.P.
    • Geomechanics and Engineering
    • /
    • 제7권1호
    • /
    • pp.87-103
    • /
    • 2014
  • This study investigated the effect of soil-structure interaction (SSI) on the response of base-isolated buildings. Seismic isolation can significantly reduce the induced seismic loads on a relatively stiff building by introducing flexibility at its base and avoiding resonance with the predominant frequencies of common earthquakes. To provide a better understanding of the movement behavior of multi-story structures during earthquakes, this study analyzed the dynamic behavior of multi-story structures with high damping rubber bearing (HDRB) behavior base isolation systems that were built on soft soil. Various models were developed, both with and without consideration of SSI. Both the superstructure and soil were modeled linearly, but HDRB was modeled non-linearly. The behavior of the specified models under dynamic loads was analyzed using SAP2000 computer software. Erzincan, Marmara and Duzce Earthquakes were chosen as the ground motions. Following the analysis, the displacements, base shear forces, top story accelerations, base level accelerations, periods and maximum internal forces were compared in isolated and fixed-base structures with and without SSI. The results indicate that soil-structure interaction is an important factor (in terms of earthquakes) to consider in the selection of an appropriate isolator for base-isolated structures on soft soils.