• 제목/요약/키워드: rotational behavior

검색결과 371건 처리시간 0.024초

동역학적 모델링을 통한 편심 회전체의 거동 해석 (Dynamical behavior of the eccentric rotor system using mathematical modeling)

  • 조문갑;조용구;김동원;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.313-318
    • /
    • 2003
  • The vibration of washing machine at spinning cycle is important problem that affects the performance of a product. In this raper, the inner structure of the washing machine is modeled as a rigid body suspension system and transfer farce caused by rotating unbalance mass is obtained using Newton's the 2nd law. and this model is used to predict the verge of walking instability during the spinning cycle. The walk of the drum washing machine is suggested by calculating the force transmissibility between drum and the cabinet. As calculating the resultant force exerted for cabinet, the friction coefficient of the pad is suggested to avoid the walk. In addition, relation between translational slip and rotational slip is derived and method to avoid the rotational slip is introduced.

  • PDF

Effects of Li$^+$ and Ag$^+$ Ions on the Rotational Barrier in Acetamide and propionamide System

  • Kwon, Dae-Keun;Choi, Young-Sang;Yoon, Chang-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권1호
    • /
    • pp.1-5
    • /
    • 1986
  • The influences of $LiNO_3\;and\;AgNO_3$ on the N-C(O) rotational barrier of N,N-dimethylacetamide and N,N-dimethylpropionamide have been investigated. The rotational activation free energy $({\Delta}G^{\neq})\;for\;Li^{+}$-amide complexes is found to increase with increasing salt concentration. On the other hand, that for $Ag^+$-amide complexes increases in the presence of $Ag^+$ ion up to 0.25 M ion concentration and then decreases as the concentration of $Ag^+$ ion is further increased. Such an unusual behavior of $Ag^+$-amide complexes has been interpreted in terms of ion-pairing and diluent effect on the amides. However, $^{13}C$ nmr chemical shift data for the amides have shown that both of these ions interact primarily with the carbonyl group in amides.

Rotational capacity of shallow footings and its implication on SSI analyses

  • Blandon, Carlos A.;Smith-Pardo, J. Paul;Ortiz, Albert
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.591-617
    • /
    • 2015
  • Standards for seismic assessment and retrofitting of buildings provide deformation limit states for structural members and connections. However, in order to perform fully consistent performance-based seismic analyses of soil-structure systems; deformation limit states must also be available for foundations that are vulnerable to nonlinear actions. Because such limit states have never been established in the past, a laboratory testing program was conducted to study the rotational capacity of small-scale foundation models under combined axial load and moment. Fourteen displacement-controlled monotonic and cyclic tests were performed using a cohesionless soil contained in a $2.0{\times}2.0{\times}1.2m$ container box. It was found that the foundation models exhibited a stable hysteretic behavior for imposed rotations exceeding 0.06 rad and that the measured foundation moment capacity complied well with Meyerhof's equivalent width concept. Simplified code-based soil-structure analyses of an 8-story building under an array of strong ground motions were also conducted to preliminary evaluate the implication of finite rotational capacity of vulnerable foundations. It was found that for the same soil as that of the experimental program foundations would have a deformation capacity that far exceeds the imposed rotational demands under the lateral load resisting members so yielding of the soil may constitute a reliable source of energy dissipation for the system.

T-스티프너 보강 CFT 기둥 - H형강보 실대형 접합부의 거동 (Behavior of CFT Column to H-Beam Full-Scale Connections with External T-Stiffeners)

  • 김영주;강창훈;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제13권6호
    • /
    • pp.715-723
    • /
    • 2001
  • 이 논문은 T-스티프너보강된 GFT기둥-H형강보 실대형 접합부의 거동을 나타낸다. 수직요소와 수평요소로 구성된 6개 실험체의 T-스트프너는 보의 전소성모멘트에 대한 강도비를 주요변수로 하여 제작되었다. 실험을 통하여 얻은 주요 내용은 강도, 강성과 소성회전능력이다. 모든 실험체는 대체로 안정된 이력거동을 나타내었으며, 특히 수평요소는 수직요소보다 강도와 강성에 더욱더 큰 영향을 준다. 보의 소성회전성능에 있어서, 조기에 파단한 TS-2를 제외한 실험체들의 평균 보소성회전각은 2.97% rad.이다.

  • PDF

Motion behavior research of liquid micro-particles filtration at various locations in a rotational flow field

  • Yan, Yan;Lin, Yuanzai;Cheng, Jie;Ni, Zhonghua
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.163-170
    • /
    • 2017
  • This study presents a particle-wall filtration model for predicting the particle motion behavior in a typical rotational flow field-filtration in blower system of cooker hood. Based on computational fluid dynamics model, air flow and particles has been simulated by Lagrangian-particle/ Eulerian-gas approaches and get verified by experiment data from a manufacturer. Airflow volume, particle diameter and local structure, which are related to the particle filtration has been studied. Results indicates that: (1) there exists an optimal airflow volume of $1243m^3/h$ related to the most appropriate filtration rate; (2) Diameter of particle is the significant property related to the filtration rate. Big size particles can represent the filtration performance of blower; (3) More than 86% grease particles are caught by impeller blades firstly, and then splashed onto the corresponding location of worm box internal wall. These results would help to study the micro-particle motion behavior and evaluate the filtration rate and structure design of blower.

Effect of connection modeling on the seismic response of steel braced non-moment resisting frames

  • Bagheri, Saman;Tabrizi, Navid Vafi
    • Structural Engineering and Mechanics
    • /
    • 제68권5호
    • /
    • pp.591-601
    • /
    • 2018
  • Non-moment beam-to-column connections, which are usually referred to as simple or shear connections, are typically designed to carry only gravity loads in the form of vertical shears. Although in the analysis of structures these connections are usually assumed to be pinned, they may provide a small amount of rotational stiffness due to the typical connection details. This paper investigates the effects of this small rotational restraint of simple beam-to-column connections on the behavior and seismic response of steel braced non-moment resisting frames. Two types of commonly used simple connections with bolted angles, i.e., the Double Web angle Connection (DWC) and Unstiffened Seat angle Connection (USC) are considered for this purpose. In addition to the pinned condition - as a simplified representation of these connections - more accurate semi-rigid models are established and then applied to some frame models subjected to nonlinear pushover and nonlinear time history analyses. Although the use of bracing elements generally reduces the sensitivity of the global structural response to the behavior of connections, the obtained results indicate considerable effects on the local responses. Namely, our results show that consideration of the real behavior of connections is essential in designing the column elements where the pin-connection assumption significantly underestimates design of outer columns of upper stories.

Behavior of semi-rigid steel frames under near- and far-field earthquakes

  • Sharma, Vijay;Shrimali, Mahendra K.;Bharti, Shiv D.;Datta, Tushar K.
    • Steel and Composite Structures
    • /
    • 제34권5호
    • /
    • pp.625-641
    • /
    • 2020
  • The realistic modeling of the beam-column semi-rigid connection in steel frames attracted the attention of many researchers in the past for the seismic analysis of semi-rigid frames. Comparatively less studies have been made to investigate the behavior of steel frames with semi-rigid connections under different types of earthquake. Herein, the seismic behavior of semi-rigid steel frames is investigated under both far and near-field earthquakes. The semi-rigid connection is modeled by the multilinear plastic link element consisting of rotational springs. The kinematic hysteresis model is used to define the dynamic behavior of the rotational spring, describing the nonlinearity of the semi-rigid connection as defined in SAP2000. The nonlinear time history analysis (NTHA) is performed to obtain response time histories of the frame under scaled earthquakes at three PGA levels denoting the low, medium and high-level earthquakes. The other important parameters varied are the stiffness and strength parameters of the connections, defining the degree of semi-rigidity. For studying the behavior of the semi-rigid frame, a large number of seismic demand parameters are considered. The benchmark for comparison is taken as those of the corresponding rigid frame. Two different frames, namely, a five-story frame and a ten-story frame are considered as the numerical examples. It is shown that semi-rigid frames prove to be effective and beneficial in resisting the seismic forces for near-field earthquakes (PGA ≈ 0.2g), especially in reducing the base shear to a considerable extent for the moderate level of earthquake. Further, the semi-rigid frame with a relatively weaker beam and less connection stiffness may withstand a moderately strong earthquake without having much damage in the beams.

Flexural behavior of precast concrete wall - steel shoe composite assemblies with dry connection

  • Wu, Xiangguo;Xia, Xinlei;Kang, Thomas H.K.;Han, Jingcheng;Kim, Chang-Soo
    • Steel and Composite Structures
    • /
    • 제29권4호
    • /
    • pp.545-555
    • /
    • 2018
  • This study aimed to investigate the flexural behavior of precast concrete (PC) wall - steel shoe composite assemblies with various dry connection details at mid-span. Flexural tests were performed for five scenarios. Test parameters included the width of test specimens, arrangement of steel shoe connectors, and use of structural adhesive or waterproof tape at the mid-span joint. The test results showed that the PC wall - steel shoe composite assemblies joined at mid-span showed flexural damage patterns combined with rotational deformation, and the structural performance was satisfactory regardless of the arrangement of steel shoe connectors. Considering the two deformation components (flexural deformation by bending and rotational deformation due to joint opening), a theoretical model was proposed to analyze flexural strength and joint opening, and the simple model gave good predictions with acceptable accuracy.

직사각형 액체저장탱크의 동적 응답특성에 관한 진동대 실험 (Shaking Table Test of a Rectangular Liquid Storage Tank)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.209-214
    • /
    • 2000
  • Shaking table tests were performed to investigate dynamic behavior of a three dimensional flexible rectangular liquid storage tank. Response characteristics to the three components of translational motion and three component of rotational motion were studied. The aluminium tank was exposed to the shaking high enough to make it behave in nonlinear range. Only very limited amount of the data have been processed yet. Very interesting phenomena on the effects of non-symmetry have been observed and presented. Test results that show nonlinear behavior under the high intensity shaking are reported.

  • PDF

온도에 의한 궤도의 후좌굴 거동 (Post-Buckling Behavior of the Track due to Temperature)

  • 임남형;이지하;강윤석;양신추
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.442-447
    • /
    • 2003
  • The actual behavior of the railroad track structure is suspected to be a complex interaction between the vertical, lateral, longitudinal, and torsional behaviors. A FE program are developed in the present study to be used for extensive nonlinear analysis of the track structures subjected to thermal load. Using the rigorous study on the deformed shape of the rail and tie, and stress resultants, characteristics of the three dimensional behavior are investigated. It is found that the flexural rigidity of the tie and the rotational stiffness of pad-fastener can be affect the behavior of the track structure and the postbuckling behavior in each rail, except lateral behavior, is not same.

  • PDF