Evaluation of Microleakage with Retrograde Filling Materials in Blood Contamination (혈액 오염된 역충전 재료의 미세누출 평가)

  • Cho, Hye-Jin;Moon, Jhong-Hyun;Chon, Seong-Min;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2007
  • The purpose of this study was to evaluate the microleakage of root-end filling material filled in blood contaminated root-end cavity and self-etching adhesive placed over blood contaminated resected root apices without root-end preparation. Extracted, human maxillary incisors, canines and mandibular premolar were randomly divided into four groups of 15 teeth each. After canal preparation, resection of the apex and root-end preparation, MTA and IRM were filled in the root-end cavity (A and B group). After canal preparation and resection of the apex, Clearfil SE Bond and Prompt L-Pop were applied over the contaminated root-end surfaces (C and D group). The roots were then subjected to 15cm of water pressure to simulate periapical microleakage stress. Data were analyzed using one-way ANOVA. The results were as follows : 1. All groups showed a tendency of decreasing microleakage in process of time after 2weeks later except IRM group. 2. After 2 weeks and 1 month, MTA group showed less microleakage significantly than other groups(p<0.05). After 2 months, Prompt L-Pop group showed less microleakage significantly than other groups(p<0.05). 3. After 9 months, there were no significant differences among four groups(p>0.05). Thus it is considered that apical sealing using adhesives system without root-end preparation is good method in endodontic surgery.

Essential of Endodontic microsurgery with the use of a Surgical Operating Microscope (외과적 근관치료의 핵심 - 치근단 미세누출 폐쇄술)

  • Kim, Sunil
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.556-564
    • /
    • 2017
  • Endodontic surgery is a procedure to treat apical periodontitis or abscess in cases that did not heal after nonsurgical treatment or retreatment. This might include situations with persistent intracanal infection after root canal treatment. Other reasons might be found in extraradicular infection, such as bacterial biofilm on the apical root surface or bacteria within the lesion. For many years, the treatment standard was the traditional approach with surgical burs and amalgam for root-end filling. Endodontic microsurgery is the most recent step in the evolution of endodontic surgery, applying not only ultrasonic tip and biocompatible filling materials but also incorporating high-power magnification and illumination. Although many studies have been published that advocate the use of modern technique, the traditional techniques are still widely used in the surgery community. The purpose of this study was to demonstrate the endodontic microsurgery procedure including the root-end preparation and filling with the use of a surgical operating microscope.

  • PDF

Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

  • Kwak, Sang-Won;Moon, Young-Mi;Yoo, Yeon-Jee;Baek, Seung-Ho;Lee, WooCheol;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.276-281
    • /
    • 2014
  • Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

SPECTROPHOTOMETRIC EVALUATION OF SEALING EFFECTS OF SEVERAL ROOT-END FILLING MATERIALS (분광광도법을 사용한 수종 역충전재의 근단부 폐쇄효과에 관한 연구)

  • Yi, Jin-Gyu;Park, Sang-Jin;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.449-456
    • /
    • 2003
  • The purpose of this study is to evaluate the sealing effect of several root-end filling materials using spectrophotometric analysis. 180 single root teeth with one canal were instrumented and canal filled. Root resected and root end preparation was made. Teeth were randomly classified to S experimental group(MTA, EBA, IRM, TCP, ZOE) and 1 control group according to root-end filling material MTA group used PRO ROOT MT A, EBA group used Super EBA. TCP group used NEW APATITE LINER TYPE II main component of which is ${\alpha}-tricalcium$ phosphate (TCP). According to manufacture's instruction experimental material was mixed and retrfilled. After 2% methylene blue solution penetration absorbance for each test sample was measured with spectrophotometer (JASCO UV-530, Japan). The mean absorbance of control and experimental group was as follows; MTA: 0.092, IRM: 0.226, Super EBA: 0.255, ZOE: 0.374, Control: 0.425, TCP: 0.501 and the result analyzed by Turkey test at P=0.05 level. Conclusions of this study are as follows; 1. The absorbance increase in following sequence MTA, IRM, Super EBA, ZOE, Control. TCP. 2. MTA showed the least leakage but was not significant with IRM or Super EBA and was significant with control or TCP(p<0.05). 3. TCP had the most leakage and was not significant with control group.

EFFICIENCY OF ULTRASONIC ROOT-END RETROGRADE CAVITY PREPARATION AND ITS INFLUENCE ON TOOTH STRUCTURE (초음파기구의 치근단 역충전와동형성 효율 및 치질에의 영향)

  • Lee, Jae-Whan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.546-559
    • /
    • 1997
  • The purposes of this study were to evaluate the efficiency of cavity preparation and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with ultrasonics. 91 distobuccal root-ends of extracted human maxillary first molars were cut by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw, retrocavities were prepared using a slow-speed no. 2 round bur as controls, and stainless steel ultrasonic tips of power settings of 1 through 10 as experimentals. Time consumed and the number of strokes used for the cavity preparation were measured and evaluated, and the incidence of tooth cracks was observed under a stereomicroscope. The results were as follows : For the retrograde cavity preparation, time and number of strokes used were decreased as the ultrasonic power setting increased (p<0.001). High power setting of ultrasonics induced significantly more tooth cracks than did the slow-speed bur or low- and medium power setting of ultrasonics (p<0.05). Teeth with previous crack induced significantly more tooth cracks than those without previous one when high power setting of ultrasonics were used for the retrograde cavity preparation (p<0.001). Teeth with initial apical canal size of no. 10 induced significantly more crack than did those with size of no. 15 when low power setting of ultrasonics were used for the retrograde cavity preparation (p<0.05).

  • PDF

CLEANLINESS AND WALL MORPHOLOGY OF ROOT-END RETROGRADE CAVITY MADE BY ULTRASONIC DIAMOND INSTRUMENTS (초음파 다이아몬드 기구로 형성된 치근단 역충전 와동의 정화도 및 와벽형태)

  • Kim, Sung-Kyo;Lim, Choon-Hee;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.515-524
    • /
    • 1998
  • The purposes of this study were to observe the cavity wall morphology and to evaluate the degree of cavity cleanliness when root-end retrograde cavity preparation was done with ultrasonic diamond instruments. To observe the morphology of retrocavity and to evaluate the degree of cavity cleanliness. root-end resections were done on 20 palatal roots of extracted maxillary first molars after canal filling with gutta-percha. Retrocavities were prepared using either ultrasonic diamond instruments or stainless steel ones of medium power setting of level 6 ($Miniendo^{TM}$, EIE, CA, U.S.A.). Morphology of the cavity. degrees of the remaining canal debris and smear layer were evaluated under the scanning electron microscope. The results were as follows: Cavities prepared with ultrasonic diamond instruments showed scratched appearance of wall, while ultrasonic stainless steel preparation showed hatcheted appearance. Ultrasonic diamond instruments induced more smear layer than stainless steel ones did (p<0.01) in the cavity. However, there was no significant difference in canal debris (p>0.05).

  • PDF

The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. (ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구)

  • Kim, Seok-Min;Park, Dong-Sung
    • The Journal of the Korean dental association
    • /
    • v.45 no.6 s.457
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

EFFICIENCY OF DENTIN CUTTING AND ROOT -END RETROCAVITY PREPARATION USING ULTRASONIC DIAMOND INSTRUMENTS AND THEIR INFLUENCE ON TOOTH STRUCTURE (초음파 다이아몬드 기구의 상아질 삭제 효과, 치근단 역충전 와동 형성효율 및 치질에의 영향)

  • Lim, Choon-Hee;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.54-67
    • /
    • 1998
  • The purposes of this study were to evaluate the efficiency of dentin cutting and root-end cavity preparation, and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with. ultrasonic diamond instruments. To evaluate the efficiency of dentin cutting, ultrasonic diamond and stainless steel instruments were applied to 20 exposed bovine dentin surfaces perpendicularly or parallely at the low, and medium power settings for 1 minute ($Miniendo^{TM}$, EIE, CA, U.S.A.). The resultant cavity depth was measured. To evaluate the efficiency of cavity preparation and to investigate the incidence of tooth crack, 165 mesiobuccal, distobuccal and palatal root-ends of extracted human maxillary first molars were resected by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw after root canal preparation and filling. Retrocavities were prepared using a ultrasonic diamond instrument or a stainless steel one of the low- or medium power settings of 2 or 6. Time consumed and the number of strokes used for the cavity preparation were measured and the incidence of tooth cracks was evaluated under a stereomicroscope. The results were as follows: Both at the low and medium power settings, and both with perpendicularly- and parallely applied tips to dentin, diamond instruments showed higher dentin cutting efficiency than stainless steel ones did (p<0.01). When tips were applied to dentin perpendicularly, both diamond instrument and stainless steel one showed higher cutting efficiency with medium power setting than with low power one (p<0.01). Both at the low- and medium power settings, both diamond instrument and stainless steel one showed higher cutting efficiency when tips were applied perpendicularly to dentin surface than applied parallely (p<0.01). At the medium power setting, the number of stroke and time consumed were less with diamond instrument than with stainless steel one (p<0.05) for the retrograde cavity preparation. At the low power setting, diamond instrument induced less tooth cracks than stainless steel one did (p<0.01).

  • PDF

CLEANLINESS AND WALL MOPHOLOGY OF ULTRASONIC ROOT-END RETROGRADE CAVITY (초음파로 형성된 치근단 역충전와동의 정화도 및 와벽형태)

  • Kim, Sung-Kyo;Lee, Jae-Whan;Baek, Seung-Moo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.536-545
    • /
    • 1997
  • The purposes of this study were to evaluate the degree of cavity cleanliness and to observe cavity wall morphology when root-end retrograde cavity preparation was done with ultrasonics. Root resections were done on 20 extracted human maxillary central incisors after canal filling with gutta-percha, and retrocavities were prepared using a slow-speed round bur as a control, and stainless steel ultrasonic tips of power settings of 2 and 6 ($Miniendo^{TM}$, EIE, SA, USA) as experimentals. The degree of the remaining cavity debris and smear layer, and wall morphology were evaluated under the scanning electron microscope. The results were as follows : Cavity prepared with ultrasonics of either power setting showed significantly less smear layer than did slow-speed preparations (p<0.01). However, there was no significant difference in canal debris (p<0.05). Cavity prepared with ultrasonics showed hatcheted appearance of wall, while slow-speed preparation showed relatively plain one.

  • PDF

COMPARISON OF THE SEALING ABILITY OF VARIOUS RETROGRADE FILLING MAIERIALS (수종의 역충전 재료의 치근단 밀폐력 비교)

  • 황윤찬;강인철;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.379-386
    • /
    • 2001
  • This study was performed to evaluate the sealing ability of various retrograde filling materials by using bacterial penetration and dye penetration test. One hundred and forty extracted human teeth with single, straight canals and mature apiece were collected and used for this study. All canals were instrumented using an engine driven Ni-Ti file (ProFile). After removing 3mm from the apex of tooth, a standardized 3mm root end cavity was prepared using an ultrasonic instrument. The 70 teeth were randomly divided into 7 groups : 6 groups for retrograde filling using Super-EBA, ZOE, Chelon-Silver, IRM, ZPC and amalgam. The 7th group was used as a negative control. Nail varnish was applied to all external root surfaces to the level of the reseated root ends to prevent lateral microleakages. The specimens were then sterilized in an ethylene oxide sterilizer for 24 hours. 2 mm of the reseated root was immersed in a culture chamber containing a Tripticase Soy Broth with a phenol red indicator. The coronal access of each specimen was inoculated every 72 hours with suspension of Proteus vulgaris. The culture media were observed every 24hours for color change indicating bacterial contamination. The specimens were observed for 4weeks. The remaining 70 teeth were submitted to a dye penetration test. The canals of all teeth were first sealed with AH26 and obturated using an Obtura II system. Root resection, root end preparation and retrograde filling was performed as above. All specimens were suspended in 2% methylene blue dye for 72 hours before being ion gitudinally split. The degree of dye penetration was then measured using a stereomicroscope at 10 magnification and evaluated. The results were as floows : 1. In the bacterial penetration, the degree of leakage was the lowest in the Super-EBA, followed by, in ascending order, ZOE, Chelon-Silver IRM and ZPC. The amalgam showed highest bacterial leakage of all(p<0.01). 2. In the dye penetration, the degree of microleakage was the lowest in the Chelon-Silver and Super-EBA, followed by, in ascending order, IRM, ZPC. The ZOE and amalgam showed the highest microleakage of all (p<0.05). These results suggested that the eugenol based cement, Super-EBA, have excellent sealing ability as a retrograde filling material.

  • PDF