• Title/Summary/Keyword: root distribution

Search Result 990, Processing Time 0.028 seconds

Residual Solvents and Mineral Contents in Ginseng Extracts with Different Extracting Conditions (추출조건에 따른 인삼농축액 중의 잔류용매 및 무기물 함량)

  • Lee, Seon-Hwa;Kim, Woo-Seong;Kim, Yong-Mu;Hong, Yeong-Pyo;Ahn, Yeong-Soon;Park, Heung-Jai;Kim, Ok-Hee
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • This study was conducted to investigate the contents of residual solvents and mineral components(11 kinds) in ginseng extracts with different extracting conditions(5 types) and commercial ginseng extract products(domestic, imported). Fine root was extracted with solution having various ethanol concentration after hexane treatment. Among 5 type extracts, residual solvent(hexane) was detected ginseng extracts treated ethanol mixed with hexane. But extracts that dried after soaked in hexane wasn't detected hexane. Mineral components(Al, Mn, Fe, Cu and Zn) were detected in fine root and 5 types of extracts. The contents of mineral components between fine root and extracts with various extracting conditions were similar, however, extracts that dried after soaked in hexane showed the lower amount in Al, Fe, Pb than the others. In comparison with commercial ginseng ex-tract products(domestic, imported), the distribution pattern of mineral was similar but the contents were a little different.

A Report of Two Root Mealybugs (Hemiptera: Rhizoecidae) on Non-native Ornamental Plants in Korea (우리나라 비자생 관엽식물에서 발견된 뿌리가루깍지벌레 2종 (노린재목, 뿌리가루깍지벌레과)의 보고)

  • Suh, Soo-Jung;Park, Young Mi;Cho, Myoung Rae
    • Korean journal of applied entomology
    • /
    • v.52 no.3
    • /
    • pp.255-259
    • /
    • 2013
  • Two root mealybugs, Ripersiella multiporifera Jansen and Rhizoecus albidus Goux, were collected on imported Dracaena plants (Dracaenaceae) and Schlumbergera truncata (Haw.) Moran (Cactaceae) grown in greenhouses in Korea. Both species were probably introduced into greenhouses via the plant trade. Therefore, it reiterates the need to focus attention on the detection of root mealybugs at the ports of entry to prevent their introduction and establishment in the Korean environment. In this paper, additional information for the two species is provided with diagnoses, photographs along with host plant and distribution data for accurate species identification.

Analysis of the Phillips Curve: An Assessment of Turkey

  • NAR, Mehmet
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.2
    • /
    • pp.65-75
    • /
    • 2021
  • This study analyzes the validity of the Phillips curve with regards to Turkey. The existence and direction of the causality relationship (reason-outcome relationship) between unemployment and inflation is investigated using inflation and unemployment data for the period 1980-2019. Unit root tests were utilized to evaluate the stationarity of the series. In line with the Zivot-Andrews unit root test, which was developed in response to the criticism of the failure of studies that presented macro-variables like inflation to consider traditional unit root tests, in this research, the Engle-Granger cointegration test was implemented to check whether the series could perform a joint action, and, finally, the Granger causality relationship was explored. According to the results of the analysis, over the relevant period there was a single directional causality relationship from inflation toward unemployment in Turkey. The importance of this relationship at the 10% significance level indicates the existence of many different factors that affect inflation and unemployment. Given the existence of a cointegration and causality relationship between inflation and unemployment, it can be said that, in Turkey, the Phillips curve is valid for the period 1980-2019 and that an increase of 1% in inflation will reduce the unemployment rate by 0.028%.

Root Development end Branching farms of Norway Spruce(Picea abies) in the Differently Acidified Forest Soil (토양(土壤) 산성화(酸性化) 정도(程度)에 따른 독일가문비나무(Picea abies)의 뿌리 발달(發達)과 분지형태(分枝形態)에 관(關)한 연구(硏究))

  • Lee, Do-Hyung
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.4
    • /
    • pp.458-464
    • /
    • 2001
  • In this study, the annual growth of roots and their branching forms of Norway spruce(Picea abies [L.] Karst.) were analysed to compare the development of their root in the differently acidified forest soils. And there was no significant difference among the stands for the modified roots and the non-modified roots depending on the root branch forms, and however in the most acidified Weidenbrunnen stand, the modified roots, the abnormal root branch form such as fork, gun and rake types were appeared. As a result of the ring of the root, the annual horizontal root growth were 6.3cm for Weidenbrunnen and Barbis stands and 9.5cm for Eberg$\ddot{o}$tzen stand. The average annual vertical root growth was 4.4cm, 5.4cm, and 6.7cm for Weidenbrunnen stand, Barbis stand, and Eberg$\ddot{o}$tzen stand, respectively. The cross section area by root distribution at 80cm deep showed that the thick and thin roots were evenly distributed in of Eberg$\ddot{o}$tzen stand and the sum of root cross section area was $32.6cm^2$. In Barbis stand, the thick roots were distributed in the center while the thin roots were comparatively rare. And the sum of root cross section area was $29.2cm^2$. In Weidenbrunnen stand, only a few thin roots were found, and the total root cross section area was $10.9cm^2$. The stability coefficient of roots were in the order of Eberg$\ddot{o}$tzen stand(1.04), Barbis stand (0.3), and Weidenbrunnen(0.08) stand. Among the investigated Norway spruce stands, the modified abnormal root branching form and the low root growth appeared in the Weidenbrunnen stand could be attributed by the soil acidification etc.

  • PDF

The Study on Stress Distibution of a Slotted Plate (슬롯 을 갖는 平板 의 應力分布擧動 에 관한 硏究)

  • 송삼홍
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.4
    • /
    • pp.367-376
    • /
    • 1982
  • Stress concentration mainly occurs near holes and notches. Then local stress is larger than nominal stress. It is necessary that stress concentration phenomena are studied because it can act as a cause of fracture of material. In order to analyze fracture of material including holes, stress concentration factor and stress distribution must be studied more carefully. In this paper the stress concentration and distribution of a slotted plate is examined. Hardened 7:3 brass plate with 4 different slots including a circular hole is used. And ratios of slot length to its root radius are 1, 2, 3, 24, 4. The stress distribution is measured by using strain gages attached to the plate with variable width. And obtained experimental data are adjusted by using calibrated gage factor.

An Experimental Study on the Characteristics of Temperature Separation for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브에서의 형상 변화에 따른 온도 분리에 관한 실험적 연구(I))

  • 황승식;전운학;김종철;이희상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial temperature distribution and the radial temperature distribution in internal space of a tube. From the study, following conclusive remarks can be made. Average flow rate that flows into a tube is in proportion to square root of inlet pressure. As inlet pressure increases axial and radial temperature distribution in the inner space of vortex-tube increase. As mass flow rate ratio change, separation point moves.

  • PDF

Estimation based on lower record values from exponentiated Pareto distribution

  • Yoon, Sanggyeong;Cho, Youngseuk;Lee, Kyeongjun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.5
    • /
    • pp.1205-1215
    • /
    • 2017
  • In this paper, we aim to estimate two scale-parameters of exponentiated Pareto distribution (EPD) based on lower record values. Record values arise naturally in many real life applications involving data relating to weather, sport, economics and life testing studies. We calculate the Bayesian estimators for the two parameters of EPD based on lower record values. The Bayes estimators of two parameters for the EPD with lower record values under the squared error loss (SEL), linex loss (LL) and entropy loss (EL) functions are provided. Lindley's approximate method is used to compute these estimators. We compare the Bayesian estimators in the sense of the bias and root mean squared estimates (RMSE).

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

Flood Frequency Analysis by the Box-Cox Transformation

  • 이순혁;조성갑;박명곤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.20-32
    • /
    • 1990
  • Abstract This study was conducted to pursue the normalization of frequency distribution by making an approach to the coefficient of skewness to nearly zero through the Box-Cox transformation, to get probable flood flows can be calculated by means of the transformation equation which has been derivated by Box-Cox transformation in the annual maximum series of the applied watersheds. It has been concluded that Box-Cox transfromation is proved to be more efficient than logarithmic, square root and SMEMAX transformation which is based on the trigonometric solution of a right triangle whose three verteces repesent the smallest, median and largest observed values of a population in making the coefficient of skewness nearer to zero. Consequently it is shown that probable flood flows according to the return period based on Box-Cox transformation are closer to the observed data as compared to other methods including SMEMAX transformation and fitted probability distributions such as the three parameter lognormal and the type I extremal distribution for the applied watersheds.

  • PDF

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF