• Title/Summary/Keyword: room cooling

Search Result 488, Processing Time 0.033 seconds

A Study on the Prediction Modeling of Phase Transformation in the CGHAZ of Structural Steel Weld (구조용강 용접부 CGHAZ의 상변태 예측 Modeling에 관한 연구)

  • 조일영;이경종;이창희
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.74-84
    • /
    • 1998
  • The microstructures of the HAZ (Heat Affected Zone) are generally different from the base metal due to rapid thermal cycle during welding process. Particuraly, CGHAZ (Coarsened Grain Heat Affected Zone) near the fusion line is the most concerned region in which many metallurgical and mechanical discontinuities have been normally generated. A computer program by the numerical formularization of phase transformation during cooling with different rates was developed to generate the CCT diagram, and to predict microstructural (phase) changes in the CGHAZ. In order to verify simulated results, isothermal and continuous cooling transformation experiments were conducted. The simulated and experimental results showed that the developed computer model could successfully predict the room temperature microstructural changes (changes in volume fraction of phases) under various welding conditions (heat input & cooling rate $(Δt_{8/5})$).

  • PDF

A study of frequency control of an inverter heat pump for indoor air temperature adjustment (실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구)

  • Park, Yun-Cheol;Min, Man-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

Novel Wafer Warpage Measurement Method for 3D Stacked IC (3D 적층 IC제조를 위한 웨이퍼 휨 측정법)

  • Kim, Sungdong;Jung, Juhwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.86-90
    • /
    • 2018
  • Standards related to express the non-flatness of a wafer are reviewed and discussed, for example, bow, warp, and sori. Novel wafer warpage measurement method is proposed for 3D stacked IC application. The new way measures heat transfer from a heater to a wafer, which is a function of the contact area between these two surfaces and in turn, this contact area depends on the wafer warpage. Measurement options such as heating from room temperature and cooling from high temperature were experimentally examined. The heating method was found to be sensitive to environmental conditions. The cooling technique showed more robust and repeatable results and the further investigation for the optimal cooling condition is underway.

Experimental Study on Indoor Thermal Environment of an Office Building During Cool ing Season (실내 열환경에 관한 실측조사 연구 -냉방기 사무소건물을 중심으로-)

  • Kim, Sung-Wan;Jang, Hai-Jin;Park, Sang-Dong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.3
    • /
    • pp.189-197
    • /
    • 1983
  • In this study, the thermal environment of a certain building was investigated by using of concerned equipments and enquete sheets. The measured items were temperature, humidity, air flow and radiant heat, and thermal responses for the occupants were checked also, which are oriented to be used as basic data for environmental design. The results of this study are as followed. 1. The optimal room temperature was $24\~26.5^{\circ}C$ DBT in cooling season. 2. Under the condition from $50\%\;to\;70\%$ of relative humidity, the difference of relative humidity did not impact upon the feeling temperature. 3. In cooling season, the average clothing factor of occupants was 0.34 clo ; 0.49 clo for men and 0.25 clo for women. 4. The average working factor of occupants was $1.1\~1.3\;Met$ in that cooling season.

  • PDF

Interior Environment and Practical Usages of the Home Economics Practice Room in Middle School of Gyeonggi and Incheon (경기$\cdot$인천지역 중학교 가정실 실내 환경과 활용 실태)

  • Cho Jae Soon;So Bok Ryea
    • Journal of Korean Home Economics Education Association
    • /
    • v.16 no.4 s.34
    • /
    • pp.127-140
    • /
    • 2004
  • The purpose of this study was to find out the interior environment, teaching equipments and tools, practical usages and related problems of the Home Economics practice room as a special room of Home Economics in middle school. The data were collected with questionnaire through a mail from 150 teachers charged in the Technology $\cdot$ Home Economics of the middle schools in the Gyeonggi Province and Incheon Metropolitan City. There were Home Economics practice rooms in the most of the middle schools. The room was used for the Home Economics class as well as for many other activities. which sometimes disturbed the class in the room. The frequency of the usage of the room was relatively low and limited mostly to the cooking class and somewhat sewing class because of the lack of environmental equipment and facilities such as heating, cooling. ventilating systems and furnishings such as table. chair as well as teaching materials. etc. Teachers wanted to use the room for all units of the Home Economics class applied to various teaching methods in the room. The improvement of the interior environments and teaching materials could facilitate the variety of the class in the Home Economic practice room.

  • PDF

On the Characteristics of the Low Velocity Displacement Air-Conditioning System (저속치환 공조시스템의 특성에 대한 연구)

  • Lee, Kye-Cheul;Kim, Dong-Kyu;Kim, Kyoung-Gu;Kwon, Young-Pil
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.493-498
    • /
    • 2001
  • In the low velocity displacement air-conditioning system, the conditioned air is supplied from the diffuser placed on the wall near the floor and vented near the ceiling. This system has some advantages upon the traditional mixing system; the air quality near the people is improved by the displacing action of the system and the energy may be saved by neglecting the cooling or heating load for the upper space of the space above the people. This study is to examine the temperature and velocity distributions in the room and near the diffuser. It is found that the temperature is stratified uniformly all over the room space to show the displacing function of the system.

  • PDF

A solution method of view factor by the area weighted average and graphical methods (면적가중 평균법과 그래프 해법에 의한 형태계수의 해석)

  • 유승호;손장열
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.709-715
    • /
    • 1999
  • To optimize a heating and cooling system, we need an exact solution lot radiant heat transfer in any form of room or building. This paper describes the solution method of view factor by the area weighted average and graphical method to calculate the radiant heat exchange or daylighting level in any form of room or building. This study shows that the area weighted average and graphical methods have many points of merits(calculation speed, correctness and calculation capability in an arbitrary form of room shapes etc.) compared with existing methods

  • PDF

Study on Ventilation Performance of Multi-room in Apartment - Airflow and Ventilation Effectiveness in Multi-room - (공동주택의 환기방식별 다수실 환기 성능에 관한 연구 - 다수실의 환기경로 및 환기효율 -)

  • Kwon, Kyung-Woo;Cho, Si-Jin;Choi, Eui-Sung;Park, Jun-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.399-404
    • /
    • 2006
  • Heating and cooling load of ventilation is a very important part of building energy saving. Improving ventilation effectiveness can save building energy consume and supply fresh air to indoor efficiently. So this study measured mulity-zone aiflow and ventilation effectiveness according to ventilation types. Result of measurement show that ventilation effectiveness is depends on ventilation system design rather than ventilation types.

  • PDF

A comparison of resident's behavior of operating air conditioner according to the charge for electric (사용자의 전기요금 부담 여부에 따른 여름철 냉방기 사용 특성의 비교)

  • Kwon, Suh-Hyun;Choi, Yoo-Rim;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.301-305
    • /
    • 2006
  • An electrical bill is one of the various factors that influence on energy use of residents. This study focused on electrical bills and searched that whether electrical bills affect resident behavior of operating air conditioner and their controlled indoor climate. We surveyed two groups for field study ; the one is residents who live in a studio apartment in Seoul and they are charged for electric as energy consumption they used, and the other is residents who live in a university dormitory and they are not charged for their energy consumption. We measured how long they used the air conditioner for cooling, on/off temperature of air conditioner and room temperature for these two groups. Residents were interviewed about their cooling needs, decisions about when to turn on their air conditioner and so on. We found that dormitory group has much amount of time used the air conditioner than studio apartment group and there are differences of room temperature between two groups when they turn on or off air conditioner. The result shows that perception of money affects resident behavior of operating air conditioner and their acceptable thermal range.

  • PDF