Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space (주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가)

  • Seok, Ho-Tae;Kim, Dong-Woo;Yang, Jeong-Hoon
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant (냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

Hermetically Sealed Refrigeration Compressor Motors and it's Protecting Device (밀폐형압축기용 전동기및 그 보호장치에 관하여)

  • 경원기계공업㈜ 압축기연구실
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.4
    • /
    • pp.257-267
    • /
    • 1978
  • Hermetically sealed refrigeration comperessor use for household refrigerotor, room air conditioner, require effective performance, stable condifion. From now, I'm going to tell you about characteristics of motors, starters and protecting device for compressors.

  • PDF

An analysis on the utility of congealing water to improve efficiency of the air cooling equipment and save energy (냉방설비 성능개선 및 에너지 절약을 위한 응결수 활용성 분석)

  • Park, Keun-Soo;Park, Young-Ho;Yu, Jeong-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.974-981
    • /
    • 2007
  • Seoul Metro has operated the air cooling equipment established in a machine room of a station building to improve our services focused on our customers who use Seoul Metro during the summer season. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. One of them is loss of efficiency in the air conditioner. The leading cause of this problem is that we use an underground type of the cooling tower. As the machine room of a station building is located in the underground of inner city because of the nature of the subway, it is difficult to establish the cooling tower on the ground. The underground structure of the No. $1{\sim}4$ subway line is unsuitable for the location requirements of the underground type of the one because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. Accordingly, the efficiency of the air conditioning is getting lower and lower. Another problem is too wasteful with water. Each station uses the water over 30 tons every day with waterworks to replenish the cooling tower such as a evaporation, a scattering and a distribution of water. Nevertheless, the more an air conditioner increase, the more the use of water supply increase. For this reason, we can't help wasting an enormous amount of water and discharging the congelation of a low temperature(about $15^{\circ}C$) occurred in a heat exchanger inside an air conditioner. The purpose of this study is to analyze the utility of congealing water to improve efficiency of the air cooling equipment and save energy as a supplementary water for the cooling tower.

  • PDF

A Study on the Room Temperature Control Methods Considering Human Thermal Comfort Under Hot and Humid Condition (인체의 온열환경 적응을 고려한 여름철의 실온 쾌적변동 제어에 관한 연구)

  • Lee, Ju-Youn
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.334-341
    • /
    • 2008
  • The purpose of this study is to investigate the effects of changing air temperature and the changing on/off periods of the air-conditioner system. Adding to that, this paper discuss is to consider the effects of air temperature with the air-conditioner system upon the human thermal comfort. The experiment is conducted during the summer. The subjects(6 young females) are exposed to the following conditions: combinations of 2 Swing and 2 Linear air control Conditions. (2 Swing during 40 min, 4 Swing during 40 min, Linear 40 min, Linear 60 min in still air and RH 50%). From the experiment, the following results are obtained; the thermal sensation vote is neutral after 90 minute. The mean skin temperature ranged about $34^{\circ}C$ at all conditions. The skin temperature was greatly affected by 2 Swing big amplitude condition.

A Study for Improving the Thermal Environment of Telecommunication Equipment Room -based on TDX-10, TDX-100, 5ESS-2000, PCM room- (통신장비실의 열환경 개선방안에 관한 연구 -TDX-10, TDX-100, 5ESS-2000, PCM실 중심으로-)

  • Cho, Chun-Sik;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.87-94
    • /
    • 2004
  • The purpose of this study is to improve thermal environment of telecommunication equipment rooms that hold TDX-10, TDX-100, 5ESS-2000, PCM of the latest telecommunication equipment. Analysis program is used the commercial CFD code, Star-CD and DOE-2.1E. The result has been compared by the energy consumption and the temperature contour at the 1 m height of room for each case. Different methods such as the relocation of the existing air-conditioner, the inflow of the ambient air into room, the installation of the forced fan and the cooling system equipment of the duct-connection type have been used to test for improvement of thermal environment. The analysis shows that most efficient method is the inflow of the ambient air into room but auxiliary equipment should be needed to prevent the local thermal spot.

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (실외기 소음원 규명 및 소음저감)

  • 서상호;이근동;이내영;진심원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.575-581
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC(Room Air Conditioner) are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan, heat exchanger and shroud. First, the fluid noise is reduced through the design ol new fan and shroud with high flow rate and low noise, reduction of the system resistance by rearrangement of heat exchanger, and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4-5dB(A).

  • PDF

A Study of Stabilizer for the Noise Reduction in Room Air Conditioner (룸에어컨 소음저감을 위한 Stabilizer에 관한 연구)

  • 서상호;이내영;이진하;진심원;임금식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.136-141
    • /
    • 1995
  • Room Air Conditioner(이하 RAC) 실내기는 열교환기, Cross Flow Fan(이하 CFF), 곡률, Stabilizer(이하 STB) 등 여러 설계인자가 소음, 풍량 및 압력 등에 상호 복합적으로 연성(Coupled)되어 있어 각 인자가 성능에 미치는 영향을 정량적으로 밝혀 내기가 쉽지 않다. 따라서 RAC 실내기의 고성능 및 저소음화를 실현하기 위해서는 실내기를 구성하는 각 인자간의 상호 관련성 및 각 인자가 소음.성능 등에 미치는 영향을 체계적으로 분석하는 것이 필수적이다. 본 연구에서는 설계인자중 소음 및 풍량에 민감한 영향을 주는 STB 위치 및 형상 등에 관하여 자세히 다루고자 한다. STB위치의 적절한 범위를 설정하기 위해 Laser Doppler Velicitimeter(이하 LDV)를 이용하여 곡률별 실내기 내부의 유속분포 및 속도 벡터를 측정하였고, CFF내부 Vortex의 정확한 위치를 찾아냈다. 또한 실내기 저소음화를 위한 소음원 규명 측면에서 실내기 내부의 난류도와 관련하여 속도 Fluctuation을 정의하고, 실험을 통해 구하였다.

  • PDF

A Study on Acceptable Thermal Comfort Zone and Resident Behavior of Operating Cooling Devices in Apartments (공동주택의 여름철 수용 쾌적온도 범위와 거주자의 냉방기 사용행위에 관한 연구)

  • Chun Chung-Yoon;Bae Nu-Ri
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.477-486
    • /
    • 2005
  • In this study, indoor thermal environment, resident behavior of operating cooling device, and thermal comfort vote are investigated at the living room of apartment during summertime in Seoul. Based on the results of the investigation, indoor air temperatures that residents turn air conditioners (especially for cooling load in this research) on and off were found out. The relationships between outdoor weather condition and the number of days using air conditioner, and whether operating patterns of the devices were also found out. The acceptable thermal comfort zone is figured out from these results, and this research is expected to contribute to the development of household air conditioner. The results can be summarized as the followings; Residents turned the air conditioner on at $29.76^{\circ}C$ of indoor air temperature, and $28.89^{\circ}C$ of $SET^\ast$. And turned the air conditioner off at $27.31^{\circ}C$ of indoor air temperature, and $23.70^{\circ}C$ $SET^\ast$. Therefore, acceptable thermal comfort zone could be lied between these temperatures. If comfortable indoor thermal environment can be obtained with various architectural passive cooling techniques based on the results, energy consumption of cooling devices will be reduced.