• 제목/요약/키워드: room acoustic analysis

검색결과 56건 처리시간 0.025초

실측을 통한 대학 강의실 음향 특성에 관한 연구 (Room acoustic analysis in university classrooms using experimental results)

  • 김윤선;송민호;박인선;박상규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.493-502
    • /
    • 2007
  • Measurements of RT, EDT, $D_{50}$, $C_{50}$ and STI carried out in three different unoccupied University classrooms. For acoustic measurements, various sound sources are used (white noise, pistol shot, MLS and sweep signal). In this study, It found that interaction exists between sound source and place. Also there was high correlation between STI and various acoustic parameter.

  • PDF

라디오시티법을 이용한 실내 음향장 해석 연구 (A Study on Room Acoustic Field Analysis using Radiosity Method)

  • 김국현
    • 대한조선학회논문집
    • /
    • 제55권5호
    • /
    • pp.394-400
    • /
    • 2018
  • Various numerical methods have been adopted for indoor noise assessments of ship plant. Acoustical radiosity method is one of the high frequency approaches for acoustic field analysis, which assumes diffuse reflections by boundaries so that it could be efficiently applied to the acoustically diffused indoor space noise analysis. In this study, an acoustic field analysis program has been developed based on radiosity method, which could apply for acoustically large enclosures such as ship's indoor space. For this purpose, the procedure of the acoustical radiosity method has been summarized and implemented to an acoustic field analysis program using MATLAB. Numerical example for a rectangular indoor space has investigated validity of the implemented program. Steady state sound pressure levels calculated for a continuous acoustic source signal have shown good agreement with those by other solutions such as an analytic solution and a ray tracing method. Instantaneous sound pressure levels calculated for an impulsive acoustic signal have provided the clues of direct/reflected acoustic field and reverberation time.

다목적홀의 공연종류에 따른 음향평가요인 분석 (Analysis of the Acoustic Evaluation Factors Depending on the in Performance Types Multi-purpose Halls)

  • 박현구;김항;김선우
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.66-74
    • /
    • 2006
  • This study aimed to evaluate the room acoustical performances of multi-purpose halls, surveying the architectural features and analysing the acoustical characteristics by measurements. In addition, adjectives appropriate for the evaluation of the room acoustical performance in multi-purpose halls were determined through the method of questionnaire survey and subjective evaluation through psycho-acoustic experiment. The results from the experiment were analysed by the correlation analysis and the factor analysis, consequently useful adjectives for the evaluation of acoustical performances in multi-purpose halls were determined depending on the types of performance.

함정의 실내소음 허용기준 설정을 위한 청감평가 및 분석 (Psycho-acoustic Evaluation and Analysis of the Indoor Noise in Cabins of a Naval Vessel to Specify its Allowable Limit)

  • 홍현수;심상렬;한형석
    • 한국소음진동공학회논문집
    • /
    • 제21권7호
    • /
    • pp.650-656
    • /
    • 2011
  • The noise inside a naval vessel is very important in considering the need for hearing protection, improving the working environment and maintaining good communications for crews living on board a naval vessel. The indoor noise of a ship usually is specified by the A-weighted sound pressure level, but other evaluating parameters are required to reflect human senses more effectively. This paper uses additional noise indices related to room acoustics, such as NR(noise rating), NC(noise criterion), RC(room criterion), PSIL(preferred speech interference level) and loudness level to evaluate the noise inside cabins on a naval vessel. Using these psychological noise indices, allowable limit of noise level in cabins is suggested through psycho-acoustic evaluation for the noise in cabins.

음향시뮬레이션을 이용한 실내음향해석 - Multiplex 영화관을 대상으로 - (Indoor Acoustic Analysis Using Acoustic Simulation Of Multiplex Cinema)

  • 윤창연;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.587-593
    • /
    • 2000
  • The background noise and transmission loss of wall were measured on site for the multiplex cinema. The results from the simulation analysis was compared with the measurements from the site for different frequencies to review the acoustical parameters, and the analysis results in the relatively small error. Therefore, it is concluded that the reliable estimation can be made once accurate data such as sound source and sound absorption coefficient of interior material is utilized during the simulation process. However, the calibration is necessary for the test room with the small room volume.

  • PDF

차실 음향 최적 설계에 관한 연구 (Optimal Design of Acoustical Characteristics of Passenger Compartment)

  • 김정수;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.183-188
    • /
    • 2003
  • This study is to make the fundamentals of sound quality evaluation in regard of acoustical characteristics of passenger compartment. The deviation of frequency response function level within audible frequency is evaluated at receiving point in the research of room acoustics. In this study, frequency response function is the one between speaker and driver's ear positions. The positions of driver and audio speakers are optimized by analysis of acoustic mode of acoustic cavity. The main reflection planes are determined by analysis sound ray path diffused at optimized speaker positions. Finally, designer selects acoustical material by analysis of absorption effect of acoustical materials on the main reflection planes in order to avoid to distortion and fluctuation of frequency response function..

  • PDF

4톤급 지게차 냉각홴 소음 저감에 관한 실험적 연구 (An Experimental Study on the Noise Reduction of Cooling Fans for Four-ton Forklift Machines)

  • 최대식;김석우;염태영;이승배
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2021
  • This paper presents research on methods for the reduction of forklifts' noise level for the increased comfort and safety of its operator. A cooling fan with a high air volume flow rate installed in the forklift acts as an important design parameter which efficiently cools the heat exchanger system, helping to transfer internal heat from the engine room to the outdoors with both transmitted and diffracted opening noises. The cooling fan contributes significantly to both the forklift's emitted sound power and the operator room's noise level, thereby necessitating research on the forklift's reduction of acoustic power level and transmission. A noise analysis for various fan models with a biomimetic design based on eagle-wing geometry was conducted. In addition to the acoustic power generation, the aerodynamic performance of the cooling blade is also strongly influenced by the design of airfoil distribution, thereby requiring optimization. The cooling fans were fabricated and installed in the forklift in order to check the efficacy of the forklift engine's cooling, and the final version of the fan was measured for its ability to lower acoustic power level and cool the engine room. This study explains the aerodynamic and acoustic features of the designed fans with the use of BEM analysis and forklift test results.

구조-음향 연성계의 민감도해석을 이용한 모형차량의 소음저감에 관한 연구 (A study on the Interior Noise Reduction of Model Car Using the Structural-Acoustic Sensitivity Analysis)

  • 박동철;이장무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.675-680
    • /
    • 1997
  • The object of this study is the numerical analysis about the sound pressure distribution in reverberation rooms. In order to obtain the effect of the boundary conditions of the wall, the sound field was computed for various absorption coefficients and impedances. And the effect of the room shape was investigated by dealing with pentagonal type as well as the rectangular type. In addition an experiment was performed for the sound pressure distribution in a reverberation room and the result was compared with the analysis.

  • PDF

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

음향강도계측법에 의한 음향투과손실의 측정 및 표면진동 모우드의 예측에 관한 연구 (A study of transmission loss and surface vibration mode by the two microphone acoustic intensity method)

  • 김의간;남청도;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.63-71
    • /
    • 1987
  • The measuring of acoustic intensity has been investigated by many researchers and practicians during the last several decades. But due to the lack of measurement accuracy, they have had no practical use. In recent years, the two microphone acoustic intensity method has been developed by the advancement of FFT analysis technique and the digital data processing equipment. This new method of using two microphones gives informations on the noise source survey and the acoustic power of sound radiation source without the anechoic room. In this paper, theoretical formulae for the two microphone acoustic intensity method and the sound transmission loss are checked. The obtained results for the acoustical enclosure of gas heat pump were compared with the classical field incidence mass law. The surface vibration modes for a panel of enclosure were also estimated.

  • PDF