• Title/Summary/Keyword: roof proof

Search Result 21, Processing Time 0.028 seconds

Establishment of the Service Life of the Education Fcilities - Focused on the Roof water-proof and Floor finishings - (교육시설 내용년한 산정 연구 - 옥상방수와 바닥마감재를 대상으로 -)

  • Lee, Kang-Hee;Chae, Chang-U
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.27-36
    • /
    • 2017
  • Educational facilities have an affect to make a decently learning environment. After constructed, it needs a maintenance plan to keep the performance or function which provide the repair time, repair scope and ratio. But the fundamental data are so insufficient that the field worker can't provide the maintenance plan and has no choice use the other data which concerned with apartment or office building. Above all, the service life is indispensible to make a repair plan because the repair time and scope would be provided within the service life. This study aimed at providing the method to make a service life of component in educational facilities and applying the method into the roof proof and floor finishing. Results are shown that first, it is important to set the $1^{st}$ repair time after constructed. when it proposes the three ways with the probability approach, choice probability model and cumulative cost function. Second, the service life of roof proof is provided with about 35 years. In addition, the service life of the floor finishing is about 40 years. These result would be utilized to conduct the repair plan under the service life.

Expansion of Cool Roof Policy through Thermal Measurement of Eco-Friendly Ceramic Coating (친환경 세라믹 도료 열적측정을 통한 쿨루프 정책 확대방안)

  • Park, Min Yong;Lee, Dong Ho
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.75-82
    • /
    • 2020
  • The urban heat island phenomenon that accelerates global warming has always been controversial when summer heatwaves have occurred since it was first investigated and described by Luke Howard in the 1810s. In Korea, since 2014, government have been interested in Cool Roof and painted white coating on the rooftops of the aging and weak buildings, and the cool roof business has expanded nationwide. However, the roof occupies 20-25% of the entire city surface, much less than 37-45% of the pavement area consisting of roads, parking lots and sidewalks, there is a need to expand the policy of Cool Pavement as a way to reduce the urban heat island phenomenon. Domestic cities are high-rise buildings centered on apartments, and the area occupied by outer walls is larger than that of rooftops compared to foreign low-rise buildings. Therefore, as a way to reduce the urban heat island phenomenon, there is a need for a policy to expand the Cool Roof in buildings and use Cool Wall in parallel. Therefore, this study aims to present the expansion of Cool Wall in buildings and Cool Pavement in urban areas, expanding the installation range of Cool Roof, by comparing and reviewing the thermal characteristics of eco-friendly ceramic coating with excellent thermal proof performance and coatings used for roof waterproofing.

A study on the Architectural Condition and Cases of BIPV-module for Roof (지붕일체형 PV모듈의 건축특성 및 적용사례 분석연구)

  • Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.49-56
    • /
    • 2006
  • The roof among the outer surfaces of buildings is an optimum place to install PV since it is the best favorable part in the building to be exposed to day light. Especially, in case of module of BIPV for Roof, it should have essentially the functions of both electricity generation and roof-finish as a construction material. The followings are the results of the study which has analyzed the architectural conditions and applications thereof at the job site. -The aesthetic function of BIPV module is very important because the roof, mostly located at the top of the buildings, is easily recognized and affects outer interior design of the building a lot. -The heat proof of BIPV for Roof could affect the energy consumption through the roof having a wide area. -For architectural condition to the weather, the roof has to ensure the stability of the weather, humidity proof, and airtightness to the wind respectively. -For architectural condition of the structure, endurance by physical power such as stability of both combining and fixing and transfer of load should be ensured. -For residents protection, it has also architectural functions to secure for the space and shield ozone, UV and noxious substances. -Through its practical applications, It is already confirmed that there are various types of BIPV modules overseas and its application has been proved successfully.

A Study on Characteristics of Roof 'Jucsim' Structure Combustion Real Scale Fire Test on Wooden Structure Heritage Building (목조 건축 문화재 적심부 실물화재 실험을 통한 연소 특성 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.95-102
    • /
    • 2010
  • The combustion characteristics of roof 'Jucsim' structure was analysed using real scale fire test on wooden structure heritage building. the fire test model was made to consider roof timberling internal structure for a Sunglemun. Structure of test body layed lime, soil, 'Jucsin' and ceiling board excepting roof tile to find heat propagation process by setting thermocouples. The first test to find fire growth and heat propagation process in the part of ceiling. The second test organized to find the efficiency of fire proof paint between ceiling board and inside of Jucsim structure. The third test try to get the performance level of fire proof fabric with the same manner. The result showed from the test proof the heavy smoke exposure with limited effect of fire proof paint however, reliable fire resistance effect showed in case of fire proof fabric.

Effect of the Eave Width and the Vertical Rain Proof Facilities on Ventilation and Air Velocity Distribution in Hanwoo Loose Barn (개방한우사의 처마와 수직 비가림시설이 환기와 풍속 분포에 미치는 영향)

  • Lee, Seung-Joo;Jo, Hyeon-Jun;Kim, Dong-Hoon;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.45 no.4
    • /
    • pp.87-93
    • /
    • 2011
  • This study was carried out to determine more effective way in eave structure between lengthening roof just as standard plan and replacing 3 types of vertical rain roof facility by using computational fluid dynamics (CFD) simulation to reduce the heat stress of Hanwoo, increase the effect of dryness of room floor, rain proof and ventilation efficiency. The simulation which did with mean wind velocity (1.2 m/s) result showed that the case of lengthening of roof just as standard design was more effective than the cases of vertical establishment of rain proof facility.

Compound waterproofing method of green roof using copper barrier sheet and recycled tire melting liquid waterproofing material that reinforced treatments are valve and glass fiber mesh. (알루미늄 판막과 유리섬유를 합지한 구리방근시트와 폐타이어 용융액상 도막방수재를 이용한 옥상녹화 복합방수공법)

  • Kim, Young chan;Cho, Il Kyu;choi, sung min;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.173-178
    • /
    • 2008
  • This is green roof bottom system which composed by aluminum valve and glass fiber together as major reinforcement, so the cooper sheet can have root proof, and using recycled tire gel-type membrane waterproofing system which dost not contains VOCs. The copper sheet reduce the plants' root growing, so it helpes to maintain the waterproofing layer and stability of root proofing. Gel type membrane waterproofing system can do waterproofing, stress dispersion, and reducing leakage expansion. So those two materials can help each other to make green roof bottom layer would have the stability and durability.

  • PDF

Characteristic of Wind Pressure Distribution on the Roof of Hyperbolic Paraboloid Spatial Structures (쌍곡포물선 대공간구조물의 지붕 풍압계수분포 특성)

  • You, Ki-Pyo;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.47-54
    • /
    • 2012
  • The roof surface of spatial structures is often damaged or destroyed because of its light weight roof structure and materials. Many of large scale stadiums have roof structure framed with steel truss or stay cable and wrapped or covered with membrane material Teflon, and this membrane material is easily damaged and its loss is quite serious. Through such examples, it was found that the studies on wind proof design of roofs of large space structures were not sufficiently made. This study conducted wind pressure experiment and fluid analysis in order to examine the aerodynamic characteristic of the roof shape of hyperbolic paraboloid spatial structures. Although the biggest minimum peak wind pressure coefficient was shown in the edges of the roof in the wind origin direction, it decreases with the advancement to the longitudinal direction of the roof.

A Study on the Establishment of the Deterioration Process Model of Roof Waterproofing in the Education facilities (교육시설의 옥상방수 열화도 진행 모델에 관한 연구)

  • Lee, Kang-Hee;Chae, Chang-U;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.11-18
    • /
    • 2017
  • Education facilities have much affect to make a good condition for the learning environment. Therefore, various approaches have been conducted to improve the physical, social and educational achievement. Especially, the physical aspect is very important to get rid of the building defect and improve the student their learning environment. For these, it needs to explain the performance and function of components and materials, which is linked with the deterioration degree. The deterioration degree is a imperative factor to make a decision whether the component would be repaired or not and to provide the repair scope of its component. In this paper, it aimed at making the deterioration degree model of roof proof under the hypothesis of which deterioration degree would be equal the repair cost at this time. Results of the study are shown that first, the $3^{rd}$ function is most proper to explain the deterioration degree model among 11 functions in view of resulted statistics. Second, the inflection of deterioration is shown at 15yr of the elementary school and 13yr of the middle and high school. This study has a limit of disclassification of the component or materials and it is, therefore, favorable to include the classification of waterproof material and work. These results would make a change from the breakdown maintenance to preventive maintenance and give a decent the learning environment for student.

Assessment of roof waterproofing by pre-packaged polymer modified slurry (PPPMS) and bitumen

  • Iqbal, Safdar;Jehan, Beenish;Khan, Fasih Ahmed;Khan, Haris;Khan, Sarmad Ali
    • Advances in environmental research
    • /
    • v.8 no.1
    • /
    • pp.71-84
    • /
    • 2019
  • Effective waterproofing of structures was a compulsory constraint to avoid leaks and dampness or humidity in walls, ceilings, roofs underground tank and underground room. Traditionally used methods of roof waterproofing were bitumen with tinny seared clay tiles are very troublesome, overwhelming time and involving high labor cost. These waterproofing methods are not allocation the purpose due to their intrinsic disadvantages. Prepackaged polymer modified slurries (PPPMS) are now attainment the vogue and easy to use, easily available in the market, cheaper in cost and more workable than the traditional methods of waterproofing. An experimental study has shown that prepackaged polymer modified slurries (PPPMS) are superior in cost and performance to as a roof water proof coatings. Bituminous coatings were mixed with water and different combination of prepackaged polymer modified slurries and primer respectively, to find optimum coverage underneath worst atmospheric conditions. Every specimen of different proportioned was applied on plane roofs and through the passage of time, their performance was checked, assessed and associated with each other. The roof of approximately 40000 ft2 area of prepackaged polymer modified slurries was used will give us hundred percent result (no water seepage or no water absorption) therefore no complaints as compare to roofs area of approximately 24000 ft2 bituminous coating was used for waterproofing they have shown the result of 30 to 40 percent water seepage. This result shows that prepackaged polymer modified slurries were two times cheaper than bituminous coating. Comparing an equal number of surfaces coated with a polymer modified prepackaged mortar and bitumen the prepackaged polymer modified slurries (PPPMS) showed excellent performance, ease of application and low bitumen coating cost.

An Experimental Study on the Capability of Arresting the Spread of a Fire of Fireproof Fabric Equipped over Ceiling Board of Wooden Cultural Properties (목조문화재 개판 상부에 설치하는 방염천의 화재전파 차단기능에 대한 실험연구)

  • Kim, Hyunju;Roh, Sam-Kew;Kim, Dong Cheol;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.297-303
    • /
    • 2012
  • This study examines the isolation-heat performance of fire proof fabric that is equipped over ceiling board in order to secure the capability of arresting the spread of a fire at roof 'Jucsim' structure of Wooden Cultural Properties. For this examination, I conduct experiments with the model and compare two construction methods of fire proof fabric, or flat-type, folding-type. The experiments show the following results. In case of installing the fire proof fabric in flat-type, when the temperature under the ceiling board is $750^{\circ}C$, the temperatures over the ceiling board is $50^{\circ}C$; the difference is $700^{\circ}C$. Compared with the case of removing fire proof fabric, the temperature over the ceiling board is lower by approximately $580^{\circ}C{\sim}600^{\circ}C$. Therefore it can be said that the construction of fire proof fabric enhances the isolation-heat performance. In case of installing the fire proof fabric in folding-type, when the temperature under the ceiling board is $600^{\circ}C$, the temperatures over the ceiling board is $65^{\circ}C$; the difference is approximately $530^{\circ}C$. Thus its isolation-heat performance is a little inferior to the flat-type equipment.